# Follett D1812R-\*\*-C1812CU-\*\* vs Manitowoc RNF2000C-261 + RCUF2200-263

Last updated 2026-11-21

The Follett D1812R-\*\*-C1812CU-\*\* and the Manitowoc RNF2000C-261 + RCUF2200-263 are both remote-condensing ice-making heads that make flake or nugget ice, rated at 1,452 and 1,475 lbs of ice a day (DOE / ENERGY STAR ratings). The Follett D1812R-\*\*-C1812CU-\*\* is rated at 4.46 kWh per 100 lbs of ice, the Manitowoc RNF2000C-261 + RCUF2200-263 at 5.06 (12% apart). At DOE's duty cycle and U.S. average rates, electricity costs about $1,331 a year for the Follett D1812R-\*\*-C1812CU-\*\* and $1,534 for the Manitowoc RNF2000C-261 + RCUF2200-263; the DOE and ENERGY STAR data give no water use for the Follett D1812R-\*\*-C1812CU-\*\* or the Manitowoc RNF2000C-261 + RCUF2200-263, so total running costs can't be compared. Neither is in the current ENERGY STAR list.

## Specifications

Each rating names its source: the DOE certification database or the ENERGY STAR list (both figures are given where they differ).

|  | Follett D1812R-\*\*-C1812CU-\*\* | Manitowoc RNF2000C-261 + RCUF2200-263 |
| --- | --- | --- |
| Brand | Follett | Manitowoc |
| Equipment type | remote-condensing ice-making head | remote-condensing ice-making head |
| Ice type | flake or nugget ice | flake or nugget ice |
| Harvest process | continuous (flaker or nugget) | continuous (flaker or nugget) |
| Cooling | remote air-cooled condenser | remote air-cooled condenser |
| Harvest rate (lbs/day) | 1,452 (DOE's certification database) | 1,475 (DOE's certification database) |
| Energy use (kWh/100 lbs ice) | 4.46 (DOE's certification database) | 5.06 (DOE's certification database) |
| Potable water (gal/100 lbs ice) | — | — |
| Condenser water (gal/100 lbs ice) | — | — |
| Refrigerant | — | — |
| ENERGY STAR certified | No | No |
| On the market since | — | — |

## Running cost a year

Estimate: the rated harvest at DOE's duty cycle (42% of the day), U.S. average commercial electricity ($0.1341/kWh, EIA) and $15 per 1,000 gallons of water and sewer (an assumption: use your own rates in the running-cost calculator).

|  | Follett D1812R-\*\*-C1812CU-\*\* | Manitowoc RNF2000C-261 + RCUF2200-263 |
| --- | --- | --- |
| Ice made a day at DOE's duty cycle (lbs) | 610 | 620 |
| Electricity a year (kWh) | 9,928 | 11,442 |
| Electricity a year (at $0.1341/kWh) | $1,331 | $1,534 |
| Water a year (gal) | — | — |
| Water and sewer a year (at $15 per 1,000 gal) | — | — |
| Running cost a year | $1,331 (electricity only: no water rating) | $1,534 (electricity only: no water rating) |

## Parts, manuals and listings

What each machine page has: the maker's parts list (pilot models), parts eBay sellers name (sellers' claims, not verified fitment), the maker's documents we link, and eBay listings of the machine (as of the last check; they change several times a day).

|  | Follett D1812R-\*\*-C1812CU-\*\* | Manitowoc RNF2000C-261 + RCUF2200-263 |
| --- | --- | --- |
| Parts in the maker's parts list (pilot) | — | — |
| Parts eBay sellers list as compatible | 0 | 0 |
| Parts sellers name for its series | 0 | 0 |
| Maker's documents linked | 0 | 2 |
| eBay listings of the machine | 0 | 0 |
| CPSC recalls | 0 | 0 |

## Go further

- [Follett D1812R-\*\*-C1812CU-\*\*: specs, running cost and parts](https://icepartsdb.com/follett/machines/d1812r-c1812cu)
- [Manitowoc RNF2000C-261 + RCUF2200-263: specs, running cost and parts](https://icepartsdb.com/manitowoc/machines/rnf2000c-261-rcuf2200-263)
- [Running cost of both, with your own rates](https://icepartsdb.com/tools/running-cost?model1=D1812R-**-C1812CU-**&model2=RNF2000C-261+%2B+RCUF2200-263#result)
- [Repair or replace the D1812R-\*\*-C1812CU-\*\*?](https://icepartsdb.com/tools/repair-or-replace?model=D1812R-**-C1812CU-**)
- [Repair or replace the RNF2000C-261 + RCUF2200-263?](https://icepartsdb.com/tools/repair-or-replace?model=RNF2000C-261%20%2B%20RCUF2200-263)

## Questions and answers

### Which makes more ice, the Follett D1812R-\*\*-C1812CU-\*\* or the Manitowoc RNF2000C-261 + RCUF2200-263?

The Manitowoc RNF2000C-261 + RCUF2200-263 is rated at 1,475 lbs per 24 hours and the Follett D1812R-\*\*-C1812CU-\*\* at 1,452, measured with DOE's test procedure (90 °F air, 70 °F water for air-cooled units).

### Which costs less to run, the Follett D1812R-\*\*-C1812CU-\*\* or the Manitowoc RNF2000C-261 + RCUF2200-263?

Only the electricity can be compared: about $1,331 a year for the Follett D1812R-\*\*-C1812CU-\*\* and $1,534 for the Manitowoc RNF2000C-261 + RCUF2200-263 at DOE's duty cycle and U.S. average rates. The DOE and ENERGY STAR data give no water use for the Follett D1812R-\*\*-C1812CU-\*\* or the Manitowoc RNF2000C-261 + RCUF2200-263, so the full running cost isn't known. Your rates and how many hours the machine runs change both.

## Sources

- [DOE Compliance Certification Database: Automatic Commercial Ice Makers](https://www.regulations.doe.gov/certification-data/) — ratings of both machines
- [EIA, Electricity explained: average U.S. commercial price, 2025 (13.41¢/kWh)](https://www.eia.gov/energyexplained/electricity/prices-and-factors-affecting-prices.php) — running-cost estimate
- [DOE, Energy Conservation Standards for Automatic Commercial Ice Makers, proposed rule (88 FR 30508, May 11, 2023), §IV.E.4 "Duty Cycle"](https://www.govinfo.gov/content/pkg/FR-2023-05-11/html/2023-09676.htm) — running-cost estimate: machines make ice 42% of the day (14% for low-capacity machines, rated 50 lb/day or less: §III.B)
- [How we build these pages (methodology)](https://icepartsdb.com/legal/editorial-policy)

Last updated: 2026-11-21

Canonical URL: https://icepartsdb.com/compare/d1812r-c1812cu-vs-rnf2000c-261-rcuf2200-263

Report a correction to this page: https://icepartsdb.com/contact/correction?page=%2Fcompare%2Fd1812r-c1812cu-vs-rnf2000c-261-rcuf2200-263