# Follett 25CI414W-\*\*-\*\*-\*\*, 25FB414W-\*\*-\*\*-\*\*, 50CI414W-\*\*-\*\*-\*\*, 50FB414W-\*\*-\*\*-\*\*, 110FB414W-\*\*-\*\*-\*\* Self-Contained Ice Machine

The Follett 25CI414W-\*\*-\*\*-\*\*, 25FB414W-\*\*-\*\*-\*\*, 50CI414W-\*\*-\*\*-\*\*, 50FB414W-\*\*-\*\*-\*\*, 110FB414W-\*\*-\*\*-\*\* is a water-cooled self-contained ice machine that makes flake or nugget ice, rated at 309 lbs of ice per day.

It uses 5.42 kWh and 130 gallons of condenser water per 100 lbs of ice.

## Specifications

| Fact | Value |
| --- | --- |
| Model number | 25CI414W-\*\*-\*\*-\*\*, 25FB414W-\*\*-\*\*-\*\*, 50CI414W-\*\*-\*\*-\*\*, 50FB414W-\*\*-\*\*-\*\*, 110FB414W-\*\*-\*\*-\*\* |
| Brand | Follett |
| Equipment type | self-contained ice machine |
| Harvest process | continuous (flaker or nugget) |
| Ice type | flake or nugget ice |
| Cooling | water-cooled |
| Harvest rate (lbs/day) | 309 (140 kg) |
| Energy use (kWh/100 lbs ice) | 5.42 |
| Condenser water (gal/100 lbs ice) | 130 |
| ENERGY STAR certified | No |
| DOE basic model | 25CI414W |
| eBay listings (ship to US) | 0 |
| Short link | https://icepartsdb.com/p/25ci414w-25fb414w-50ci414w-50fb414w-110fb414w |

## What does the 25CI414W-\*\*-\*\*-\*\*, 25FB414W-\*\*-\*\*-\*\*, 50CI414W-\*\*-\*\*-\*\*, 50FB414W-\*\*-\*\*-\*\*, 110FB414W-\*\*-\*\*-\*\* cost to run?

Estimate for a machine making ice 42% of the day (DOE's duty cycle, 88 FR 30508 §IV.E.4), from the DOE/ENERGY STAR energy and water figures.

| Item | Estimate |
| --- | --- |
| Ice made | 130 lbs/day |
| Electricity | 2,567 kWh/year ≈ $344/year |
| Water + sewer, if the condenser water runs to the drain (single-pass) | 61,581 gal/year ≈ $924/year |
| **Total** | **≈ $1,268/year** |

Formula: lbs/day × 365 ÷ 100 × kWh per 100 lbs × $0.1341/kWh ([EIA 2025 U.S. commercial average](https://www.eia.gov/energyexplained/electricity/prices-and-factors-affecting-prices.php)), plus gallons × $15 per 1,000 gal (assumption: combined water and sewer, as DOE prices it (88 FR 30508 §IV.F.5); local rates vary, so use your bill).

The water line counts the 25CI414W-\*\*-\*\*-\*\*, 25FB414W-\*\*-\*\*-\*\*, 50CI414W-\*\*-\*\*-\*\*, 50FB414W-\*\*-\*\*-\*\*, 110FB414W-\*\*-\*\*-\*\*'s condenser water (130 gallons per 100 lbs of ice, DOE/ENERGY STAR) as running to the drain (single-pass): about 61,581 gal, $924 a year. On a closed loop or cooling tower it doesn't count: about $344 a year in total.

Compare the 25CI414W-\*\*-\*\*-\*\*, 25FB414W-\*\*-\*\*-\*\*, 50CI414W-\*\*-\*\*-\*\*, 50FB414W-\*\*-\*\*-\*\*, 110FB414W-\*\*-\*\*-\*\* with other machines and with ENERGY STAR models of its size, a year and over its life: https://icepartsdb.com/tools/running-cost.md?model1=25CI414W-**-**-**%2C+25FB414W-**-**-**%2C+50CI414W-**-**-**%2C+50FB414W-**-**-**%2C+110FB414W-**-**-**

## Follett 25CI414W-\*\*-\*\*-\*\*, 25FB414W-\*\*-\*\*-\*\*, 50CI414W-\*\*-\*\*-\*\*, 50FB414W-\*\*-\*\*-\*\*, 110FB414W-\*\*-\*\*-\*\* on eBay

No eBay listings for this exact model right now (eBay checked 2026-11-24 20:42 UTC).

## Parts for the 25CI414W-\*\*-\*\*-\*\*, 25FB414W-\*\*-\*\*-\*\*, 50CI414W-\*\*-\*\*-\*\*, 50FB414W-\*\*-\*\*-\*\*, 110FB414W-\*\*-\*\*-\*\*

No eBay seller has named the 25CI414W-\*\*-\*\*-\*\*, 25FB414W-\*\*-\*\*-\*\*, 50CI414W-\*\*-\*\*-\*\*, 50FB414W-\*\*-\*\*-\*\*, 110FB414W-\*\*-\*\*-\*\* in a part listing yet. The surest way to the right part is the number on the old part (a label or a stamped number): look it up at https://icepartsdb.com/search.md?q={part number} (for example https://icepartsdb.com/search.md?q=2A1410-02) or browse Follett parts by type at https://icepartsdb.com/follett.

## Age and repair

- [Repair or replace the 25CI414W-\*\*-\*\*-\*\*, 25FB414W-\*\*-\*\*-\*\*, 50CI414W-\*\*-\*\*-\*\*, 50FB414W-\*\*-\*\*-\*\*, 110FB414W-\*\*-\*\*-\*\*?](https://icepartsdb.com/tools/repair-or-replace?model=25CI414W-**-**-**%2C%2025FB414W-**-**-**%2C%2050CI414W-**-**-**%2C%2050FB414W-**-**-**%2C%20110FB414W-**-**-**): Break-even of a repair against a new or used machine, with this model filled in

## Similar machines

Same type, harvest process and cooling, within 15% of the harvest rate.

| Model | Harvest (lbs/day) | Energy (kWh/100 lbs) | Cooling | Side by side |
| --- | ---: | ---: | --- | --- |
| [Scotsman UN324WX-1A](https://icepartsdb.com/scotsman/machines/un324wx-1a) | 316 | 4.55 | water-cooled | [Compare](https://icepartsdb.com/compare/25ci414w-25fb414w-50ci414w-50fb414w-110fb414w-vs-un324wx-1a) |

## Guides

- [Flake and nugget ice machine auger and gear motor: wear, noise and replacement](https://icepartsdb.com/guides/ice-machine-auger-gear-motor): Flake and nugget ice machine auger, bearings, water seal and gear motor: noise, overload codes, maker service intervals and live part prices.
- [Cube vs nugget vs flake ice: the ice types and the machines that make them](https://icepartsdb.com/guides/cube-vs-nugget-vs-flake-ice): Cube vs nugget (cubelet) vs flake ice: what each is for, how batch and continuous machines make it, and what each maker calls its ice.
- [Air-, water- or remote-cooled ice machine? Running costs compared](https://icepartsdb.com/guides/air-water-remote-cooled-ice-machines): What air-, water- and remote-cooled ice machines cost to run a year, from DOE and ENERGY STAR data, which ENERGY STAR covers, and when each makes sense.
- [Ice machine not making ice? Causes, checks and the parts that fix them](https://icepartsdb.com/guides/ice-machine-not-making-ice): Why a commercial ice machine makes no ice or too little, in the order a technician checks it, with the parts involved and live eBay prices.

## Questions and answers

### How much ice does the Follett 25CI414W-\*\*-\*\*-\*\*, 25FB414W-\*\*-\*\*-\*\*, 50CI414W-\*\*-\*\*-\*\*, 50FB414W-\*\*-\*\*-\*\*, 110FB414W-\*\*-\*\*-\*\* make?

It is rated at 309 lbs of ice per 24 hours in DOE's certification database, measured with DOE's test procedure (90 °F air, 70 °F water for air-cooled units). Real output is lower in hot rooms or with warm inlet water.

### What does it cost to run the Follett 25CI414W-\*\*-\*\*-\*\*, 25FB414W-\*\*-\*\*-\*\*, 50CI414W-\*\*-\*\*-\*\*, 50FB414W-\*\*-\*\*-\*\*, 110FB414W-\*\*-\*\*-\*\*?

Making ice 42% of the day, DOE's duty cycle (130 lbs/day), about 2,567 kWh a year: $344 at $0.1341/kWh, plus about $924 of water and sewer if the condenser water runs to the drain (single-pass) at $15 per 1,000 gallons.

### Is the Follett 25CI414W-\*\*-\*\*-\*\*, 25FB414W-\*\*-\*\*-\*\*, 50CI414W-\*\*-\*\*-\*\*, 50FB414W-\*\*-\*\*-\*\*, 110FB414W-\*\*-\*\*-\*\* ENERGY STAR certified?

It is not in the current ENERGY STAR list of certified commercial ice machines.

## Sources

- [DOE Compliance Certification Database: Automatic Commercial Ice Makers](https://www.regulations.doe.gov/certification-data/) — 8 fields, retrieved 2026-11-21
- [EIA, Electricity explained: average U.S. commercial price, 2025 (13.41¢/kWh)](https://www.eia.gov/energyexplained/electricity/prices-and-factors-affecting-prices.php) — running-cost estimate
- [DOE, Energy Conservation Standards for Automatic Commercial Ice Makers, proposed rule (88 FR 30508, May 11, 2023), §IV.E.4 "Duty Cycle"](https://www.govinfo.gov/content/pkg/FR-2023-05-11/html/2023-09676.htm) — running-cost estimate: machines make ice 42% of the day (14% for low-capacity machines, rated 50 lb/day or less: §III.B)
- eBay listings (Browse API search results) — 0 active listings matched to 25CI414W-\*\*-\*\*-\*\*, 25FB414W-\*\*-\*\*-\*\*, 50CI414W-\*\*-\*\*-\*\*, 50FB414W-\*\*-\*\*-\*\*, 110FB414W-\*\*-\*\*-\*\*
- [How we build these pages (methodology)](https://icepartsdb.com/legal/editorial-policy)

Last updated: 2026-11-21

Canonical URL: https://icepartsdb.com/follett/machines/25ci414w-25fb414w-50ci414w-50fb414w-110fb414w

Short link (cite this page): https://icepartsdb.com/p/25ci414w-25fb414w-50ci414w-50fb414w-110fb414w

Report a correction to this page: https://icepartsdb.com/contact/correction?page=%2Ffollett%2Fmachines%2F25ci414w-25fb414w-50ci414w-50fb414w-110fb414w