# Air-, water- or remote-cooled ice machine? Running costs compared

Last updated 2026-11-21

**Short answer:** For most kitchens an air-cooled machine is the cheapest to run. A water-cooled machine uses less electricity, but with single-pass cooling it sends its condenser water down the drain (EPA puts the total at 100 to 300 gallons per 100 lbs of ice), and at typical U.S. water and sewer rates that water costs many times what the machine saves on power. Only air-cooled machines, including remote-cooled ones, can be ENERGY STAR certified. A remote-cooled machine costs a little more to run and a lot more to install, but it moves the heat and most of the noise out of the room.

The cooling type decides where an ice machine's heat goes, and that drives its running cost, where it can go, and what
it costs to install. This guide compares air-, water- and remote-cooled machines on the energy and water figures their
makers certified to the U.S. Department of Energy.

## How each type gets rid of heat

An ice machine is a refrigeration system: it pulls heat out of water to freeze it, and it has to put that heat
somewhere. The cooling type is where the heat goes.

- **[Air-cooled](https://icepartsdb.com/glossary#air-cooled):** a fan blows room air across the [condenser](https://icepartsdb.com/glossary#condenser), so the heat ends up in the room. The machine needs free
  space around its vents and a room that doesn't get too hot. It makes less ice as the room gets warmer.
- **[Water-cooled](https://icepartsdb.com/glossary#water-cooled):** water runs through the condenser and carries the heat away. In the simplest (single-pass)
  installation it then goes straight to the drain; with a closed loop it is cooled by a chiller or cooling tower and
  reused. The room stays cooler and quieter, and output holds up better in a hot room.
- **[Remote-cooled](https://icepartsdb.com/glossary#remote-condenser):** the condenser and its fan sit outside, usually on the roof or an outside wall, connected to the ice
  machine by refrigerant lines. The heat and the fan noise stay outdoors.

## What each one costs to run

The table compares machines of the same size, using the energy and water figures their makers certified to the U.S.
Department of Energy.

| Type | Models | ENERGY STAR | kWh / 100 lbs | Condenser water, gal / 100 lbs | Electricity / year | Condenser water / year | Total / year |
| --- | ---: | --- | ---: | ---: | ---: | ---: | ---: |
| Air-cooled ice-making head | 235 | 86 of 235 | 5.00 | — | $514 (3,833 kWh) | — | **$514** |
| Water-cooled ice-making head | 65 | 0 of 65 | 4.11 | 135 | $422 (3,150 kWh) | $1,552 (103,478 gal) | **$1,975** |
| Remote-cooled (remote condenser) | 78 | 16 of 78 | 5.38 | — | $553 (4,124 kWh) | — | **$553** |

One machine rated 500 lbs/day making 210 lbs of ice a day (it makes ice 42% of the day, DOE's duty cycle), using the median energy and condenser water of the 378 DOE / ENERGY STAR models rated 400–700 lbs/day. Electricity at $0.1341/kWh (EIA 2025 U.S. commercial average); water and sewer at $15 per 1,000 gal (assumption: combined water and sewer, as DOE prices it (88 FR 30508 §IV.F.5); local rates vary, so use your bill). Every type also uses ice-making water, about 14–19 gal per 100 lbs (middle half of models), so it is left out. Compare models: [Hoshizaki machines](https://icepartsdb.com/hoshizaki/machines) · [Manitowoc machines](https://icepartsdb.com/manitowoc/machines) · [Scotsman machines](https://icepartsdb.com/scotsman/machines).

Water-cooled machines use the least electricity, but the [condenser water](https://icepartsdb.com/glossary#condenser-water) is most of what they cost to run.
Remote-cooled systems in this size range use a little more electricity than air-cooled heads, and they cost more to
buy and install.

These figures come from the DOE test, which uses the standard ratings of AHRI Standard 810: 90 °F air and 70 °F water.
Brochures and spec sheets often also quote a higher output measured at 70 °F air and 50 °F water, which Scotsman calls
"ideal conditions". A machine in a hot room or fed with warm water makes less ice and uses more energy per pound, so
treat the table as a fair comparison rather than a bill forecast. Each machine page has the same estimate for that exact
model, and you can enter your own electricity and water rates there. To compare up to three machines a year and over
their life, against ENERGY STAR models of their size, use the [running-cost calculator](https://icepartsdb.com/tools/running-cost).

## ENERGY STAR and rebates

ENERGY STAR (Version 3.0, in effect since January 28, 2018) certifies only air-cooled ice makers: air-cooled ice-making
heads, self-contained units and remote condensing units. Water-cooled ice makers are excluded, along with ice makers
with ice and water dispensing systems. If a utility rebate requires ENERGY STAR certification, a water-cooled machine
won't qualify; check the ENERGY STAR column in the table and the rebate's own rules.

## When an air-cooled machine makes sense

Air-cooled is the default choice for most restaurants, bars, offices and hotels:

- It costs the least to buy and to run, and needs only a power outlet, a water line and a drain.
- It needs room to breathe, and a clean condenser and working fan motor ([Hoshizaki](https://icepartsdb.com/hoshizaki/condenser-fan-motors), [Manitowoc](https://icepartsdb.com/manitowoc/condenser-fan-motors) and [Scotsman](https://icepartsdb.com/scotsman/condenser-fan-motors) condenser fan motors; see the
  [condenser fan motor guide](https://icepartsdb.com/guides/ice-machine-condenser-fan-motor)). EPA's WaterSense guidance says air-cooled
  machines typically need at least 6 inches of clearance around the air intake and discharge, and suit rooms at 80 °F
  or below; the installation manual gives the exact clearances and room temperatures for your model. A machine
  squeezed into a hot, closed space makes less ice and wears faster.
- In summer, the heat it puts into the room is extra work for your air conditioning.

## When a water-cooled machine makes sense

EPA's WaterSense program recommends water-cooled machines only where the location requires one, such as a room that is
consistently above 80 °F or too tight for an air-cooled machine to get enough air, and only when the machine can be
connected to a recirculating (closed-loop) cooling water system:

- The room is hot, cramped or dusty, and a remote condenser can't be installed.
- The building has a recirculating cooling water loop or cooling tower. Ask the installer whether the machine can run
  on it, because the condenser water then isn't wasted.
- Single-pass cooling sends the water to the drain. EPA puts the total water use of single-pass water-cooled machines at
  100 to 300 gallons per 100 lbs of ice, against less than 50 gallons for air-cooled ones. Check your water utility's and
  building code's rules before installing one.

## When a remote-cooled machine makes sense

- The kitchen or bar is open to customers, or already too hot, and you want the heat and fan noise outside.
- The machine is large: a big air-cooled machine puts a lot of heat into a room.
- Budget for the condenser, the refrigerant line set and the installation. Remote condensers are replaced as their own
  part: [Hoshizaki](https://icepartsdb.com/hoshizaki/condensers), [Manitowoc](https://icepartsdb.com/manitowoc/condensers) and [Scotsman](https://icepartsdb.com/scotsman/condensers) condensers.
- Many remote machines are designed to pair with a specific condenser model. Where the data names it, the machine page
  links to that condenser.

## Refrigerant and installation

The refrigerant lines of a remote system are installed by a refrigeration technician. Machines with an HFC refrigerant
such as R-404A need a technician certified under EPA Section 608 for refrigerant work. Some newer self-contained machines
use [R-290](https://icepartsdb.com/glossary#r-290) (propane), which is flammable: Manitowoc says some of its R-290 models need a minimum room size (shown on the
machine's label), that the combined charge of several R-290 machines in one room must be considered, and that only
technicians with flammable refrigerant training may work on them. The nameplate shows the refrigerant; see
[ice machine refrigerants and the EPA rules](https://icepartsdb.com/guides/ice-machine-refrigerant-r290-epa-rules). For the wider picture, see [Hoshizaki vs Manitowoc vs Scotsman](https://icepartsdb.com/guides/hoshizaki-vs-manitowoc-vs-scotsman) and
[how to size an ice machine](https://icepartsdb.com/guides/how-to-size-commercial-ice-machine).

## Questions and answers

### Is a water-cooled ice machine cheaper to run?

Not usually. It uses less electricity than an air-cooled machine of the same size, but with single-pass cooling the
condenser water it sends to the drain costs more than the power it saves at typical U.S. water and sewer rates. It also
can't be ENERGY STAR certified, and EPA's WaterSense program recommends water-cooled machines only on a recirculating
cooling loop.

### Does an air-cooled ice machine heat up the kitchen?

Yes. The heat it takes out of the water goes into the room, along with the noise of its fan. In a hot room it also makes
less ice than its certified rating, which is measured at 90 °F air and 70 °F water.

### Can a water-cooled ice machine be ENERGY STAR certified?

No. The ENERGY STAR specification for commercial ice makers (Version 3.0) covers only air-cooled machines, including
remote condensing units; water-cooled ice makers are excluded.

### Why choose a remote-cooled ice machine?

To keep the heat and the condenser fan noise out of the room. The trade-off is a higher purchase and installation cost,
and the refrigerant lines must be installed by a refrigeration technician (EPA Section 608 certified for HFC
refrigerants such as R-404A).

### Where can I see a specific machine's energy and water use?

Every machine page on IcePartsDB shows the model's rated harvest, energy use (kWh per 100 lbs of ice) and water use from
the DOE and ENERGY STAR data, with a yearly running-cost estimate you can adjust to your local rates.

## Sources

- U.S. EPA, [ENERGY STAR Program Requirements for Automatic Commercial Ice Makers, Version 3.0](https://www.energystar.gov/products/commercial_food_service_equipment/commercial_ice_makers/key_product_criteria):
  scope and excluded products (section 2), effective date January 28, 2018 (section 6).
- U.S. EPA, [*WaterSense at Work, Section 4.2: Commercial Ice Makers*](https://www.epa.gov/system/files/documents/2023-05/ws-commercial-watersense-at-work_Section_4.2_Ice_Machines.pdf),
  EPA-832-F-23-003, February 2025: cooling types and clearances (page 1), water use (pages 2–3), replacement options
  (pages 5–6).
- U.S. Department of Energy test procedure, [10 CFR 431.134](https://www.ecfr.gov/current/title-10/chapter-II/subchapter-D/part-431/subpart-H/section-431.134):
  AHRI Standard 810 (I-P)-2016 standard ratings.
- Scotsman Ice Systems, [*Ice Production FAQ Information Sheet*](https://www.scotsman-ice.com/service/Miscellaneous/IceProductionFAQ.pdf):
  90 °F air / 70 °F water (AHRI) and 70 °F air / 50 °F water rating conditions.
- Manitowoc Ice, [*Indigo NXT Air/Water/Remote Condenser Ice Machines Technician's Handbook*](https://www.manitowocice.com/asset/?id=ebxvra),
  Part Number 000018553 Rev 00 04/26: R-290 safety notices (pages 9–10).
- U.S. EPA refrigerant management rules, [40 CFR 82.154(a)(1)](https://www.ecfr.gov/current/title-40/chapter-I/subchapter-C/part-82/subpart-F/section-82.154)
  and [40 CFR 82.161](https://www.ecfr.gov/current/title-40/chapter-I/subchapter-C/part-82/subpart-F/section-82.161).
- Energy and water figures: DOE and ENERGY STAR certification data (the table above).

## More guides

- [Ice machine not making ice? Causes, checks and the parts that fix them](https://icepartsdb.com/guides/ice-machine-not-making-ice)
- [Hoshizaki ice machine beeping? What 1, 2, 3, 6 and 7 beeps mean (error codes)](https://icepartsdb.com/guides/hoshizaki-ice-machine-error-codes)
- [Manitowoc ice machine error codes (Indigo NXT E01 to E31): meanings and fixes](https://icepartsdb.com/guides/manitowoc-ice-machine-error-codes)
- [Scotsman ice machine error codes: Prodigy code display meanings and fixes](https://icepartsdb.com/guides/scotsman-ice-machine-error-codes)
- [Ice-O-Matic ice machine error codes: CIM flashing lights, GEM and MFI service lights](https://icepartsdb.com/guides/ice-o-matic-ice-machine-error-codes)
- [How to reset a commercial ice machine (Hoshizaki, Manitowoc, Scotsman, Ice-O-Matic)](https://icepartsdb.com/guides/how-to-reset-commercial-ice-machine)
- [Ice machine water inlet valve: symptoms, testing and replacement](https://icepartsdb.com/guides/ice-machine-water-inlet-valve)
- [Ice machine water pump: symptoms, testing and replacement](https://icepartsdb.com/guides/ice-machine-water-pump)

## Data sources

- DOE Compliance Certification Database and ENERGY STAR certified commercial ice machines — model counts, energy and water use
- [EIA, Electricity explained: average U.S. commercial price, 2025 (13.41¢/kWh)](https://www.eia.gov/energyexplained/electricity/prices-and-factors-affecting-prices.php) — electricity price
- [DOE, Energy Conservation Standards for Automatic Commercial Ice Makers, proposed rule (88 FR 30508, May 11, 2023), §IV.E.4 "Duty Cycle"](https://www.govinfo.gov/content/pkg/FR-2023-05-11/html/2023-09676.htm) — machines make ice 42% of the day (14% for low-capacity machines, rated 50 lb/day or less: §III.B)
- [How we build these pages (methodology)](https://icepartsdb.com/legal/editorial-policy)

Last updated: 2026-11-21

Canonical URL: https://icepartsdb.com/guides/air-water-remote-cooled-ice-machines

Report a correction to this page: https://icepartsdb.com/contact/correction?page=%2Fguides%2Fair-water-remote-cooled-ice-machines