# Flake and nugget ice machine auger and gear motor: wear, noise and replacement

Last updated 2026-11-22

**Short answer:** In a flake or nugget ice machine, a gear motor turns a stainless steel auger inside a refrigerated cylinder. The auger lifts the ice that forms on the wall and pushes it out through an extruding head or breaker at the top. The auger, its bearings, the water seal and the gear motor all wear, and scale speeds it up. A loud moaning or grinding noise, water in the drip pan, falling output and auger or gear motor alarms are the usual signs. The makers call for regular bearing checks (Scotsman at least twice a year, Hoshizaki yearly, with fuller checks after three years) and regular descaling. This is technician work; catching a worn bearing early saves the auger and the evaporator.

**Safety:** Disconnect power before servicing, and follow the manufacturer's service manual. Refrigerant work is for a qualified refrigeration technician (EPA Section 608 certified; trained for flammable refrigerants on R-290 machines), electrical work for a qualified person. Safety disclaimer: https://icepartsdb.com/legal/safety-disclaimer

Cube machines make ice in batches on a flat plate. Flake and nugget machines (Hoshizaki calls its nugget ice
cubelet) make it continuously in a cylinder, and that changes which parts wear. This guide covers the drive train that
makes the ice: the auger, its bearings, the water seal and the gear motor.

## How a flake or nugget machine makes ice

Scotsman's service manual for its Prodigy flakers describes the process:

1. A float valve in a separate reservoir keeps the water level in the evaporator, a stainless steel cylinder with
   refrigerant tubing wrapped around it.
2. Water in the gap between the evaporator wall and the auger freezes into ice crystals.
3. The auger, a stainless steel screw turning inside the cylinder, lifts the ice up the tube as a soft ribbon.
4. At the top, the ice is forced through small openings in the breaker or extruding head, which squeezes out water and
   compresses it. Scotsman's flakers have 6 oblong, curved slots (soft, wet flake ice); its nugget machines have 16 round
   holes (harder, drier nuggets). A sweep moves the ice to the chute.
5. A gear motor turns the auger. On Scotsman's Prodigy flakers it is a 1/4 HP split-phase motor driving a gear reducer
   that slows it from about 1,500 rpm to 11 rpm; the auger turns counterclockwise seen from above.

Hoshizaki's modular flakers work the same way. Their maintenance schedule names the parts: the upper bearing in the
extruding head, the lower bearing and O-ring in the lower housing, the mechanical seal, the evaporator cylinder and the
auger.

## The parts that wear

| Part | What it does | How it wears |
| --- | --- | --- |
| Auger | Lifts and pushes the ice | Scale builds up on it; if it touches the evaporator wall, its flight edges get rough and it should be replaced |
| Top (upper) bearing | Holds the top of the auger in the breaker or extruding head | Grease turns gray, wet or rusty; rollers wear |
| Bottom (lower) bearing | Holds the bottom of the auger (Hoshizaki flakers, Scotsman HID dispensers and two-auger models; Scotsman's single-auger Prodigy flakers centre the auger on the gear reducer's output shaft) | Wears with the top bearing; Hoshizaki and Scotsman replace both together |
| Water seal or mechanical seal | Keeps water in the cylinder where the auger shaft passes through | Leaks into the drip pan; water can reach the gear reducer |
| Gear motor (gear reducer) | Turns the auger | Bearings and gears wear; oil leaks; water contamination; motor windings fail |
| Evaporator (freezing cylinder) | The wall the ice forms on | Scale on the inside; scoring if the auger rubs it. Replacing it opens the refrigeration system |

Augers, breakers and extruding heads with their bearings are listed as [Hoshizaki](https://icepartsdb.com/hoshizaki/augers), [Manitowoc](https://icepartsdb.com/manitowoc/augers) and [Scotsman](https://icepartsdb.com/scotsman/augers) augers; the drive as
[Hoshizaki](https://icepartsdb.com/hoshizaki/gear-motors), [Manitowoc](https://icepartsdb.com/manitowoc/gear-motors) and [Scotsman](https://icepartsdb.com/scotsman/gear-motors) gear motors.

## Signs the auger, bearings or gear motor are wearing

| What you see or hear | Likely cause |
| --- | --- |
| A loud moaning, groaning or grinding noise (a slight crunch as ice goes through the breaker is normal) | Scale on the auger making the ice turn with it ("rotating freeze"), worn bearings, a failing gear reducer |
| The machine stops on an auger or gear motor alarm | The auger is hard to turn: scale, worn auger bearings, a damaged gear reducer, a restricted water supply from the reservoir to the evaporator, or on remote models a liquid line valve leaking through and freezing the auger in place |
| Water in the drip pan under the evaporator | Water seal or mechanical seal leaking |
| Less ice than usual | Scale, a dirty air filter or condenser, restricted water to the evaporator, a refrigeration problem |
| No ice comes out (Scotsman code 1, no ice sensed) | A refrigeration fault, or an auger motor that gets no power or has an open winding |
| Oil under the gear motor | Gear reducer seal leaking |

The machines report it, too:

- **Scotsman Prodigy flakers** watch the auger motor current. If it draws too much, the controller shuts the machine
  off, flashes a 2 in the code display and retries after 4 minutes; after repeated overloads the 2 stays on and the
  machine must be reset by hand. Scotsman says to check for damage to the gear reducer or the auger bearings, and for a
  restriction between the reservoir and the evaporator. They also watch the ice falling past the photo-eyes: if none
  falls for 10 minutes, the code display shows 1 (no ice sensed), and Scotsman says to check the refrigeration system
  and whether the auger motor gets power.
- **Scotsman HID dispensers and UF/UN X undercounters** use 2 for an auger stalled or turning too slowly and 1 for one
  turning backwards.
- **Hoshizaki modular flakers** beep 8 times (every 5 seconds) for a gear motor alarm: a relay in the gear motor circuit
  didn't close (the manual: "CCR contacts fail to close"). Hoshizaki's cubelet service manual lists a blown gear motor
  fuse, the motor's internal protector open, an open winding or a mechanical failure. Reset by switching the power off
  and on. These are not the crescent cuber beep codes.

See also the [Scotsman error codes](https://icepartsdb.com/guides/scotsman-ice-machine-error-codes), which include the flake and nugget
machines. Our [Hoshizaki beep codes](https://icepartsdb.com/guides/hoshizaki-ice-machine-error-codes) guide covers crescent cubers, whose beeps
mean different things.

## What the makers say to check, and how often

**Scotsman** (Prodigy flaked and nugget machines; "should only be done by a qualified service technician"):

- **Top bearing:** check at least twice a year, or every time the scale is removed. Remove the ice chute cover, the
  sweep and the breaker cover (left-hand threads) and look at the grease. White is new; some gray over the rollers is
  normal; add grease if gaps show. If the grease is watery, all gray or rusty, or has metal in it, replace the bearing.
- **Drip pan:** whenever you check the top bearing, look for water in the drip pan. Water means the water seal is
  leaking: service the seal and check the gear reducer's oil. Scotsman describes a check through the motor opening (on
  current X models, through a vented plug on the gearbox) that shows whether there is water in the gear case, and gives
  the correct oil charge as 14 ounces.
- **Scale:** remove scale at least twice a year, every 3 months in some water conditions.
- **When the auger is out:** inspect it for scale and wear at the top bearing surface, the drive end and the flight
  edges, and check that the evaporator wall is bright and shiny when dry. The water seal must be replaced whenever the
  auger is removed.

**Hoshizaki** (modular flakers, F and FD models):

- **Every 6 months:** clean and sanitize the machine, and check the extruding head seal bolts for leaks. Seal bolts are
  single-use and must be replaced once removed.
- **Yearly:** check the upper bearing in the extruding head for wear with a 0.02 in. round stock or pin gauge; replace
  the upper and lower bearings together if wear exceeds Hoshizaki's limits.
- **After 3 years, then yearly:** inspect the upper and lower bearings, the O-ring, the mechanical seal, the evaporator
  cylinder and the auger. Replace the mechanical seal if its contact faces are worn, cracked or scratched.

Manitowoc's flake and nugget machines have their own service manuals with their own schedules; check the manual for
your model.

## Finding the right part number

- Read the number on the old part or find it in the parts list for your model. Augers, bearings and seals are specific
  to each evaporator, and flake and nugget versions of the same machine can use different extruding heads.
- Gear motors differ in voltage, power and output; match the number and voltage. Hoshizaki's flakers, for example,
  list gear motors from a 1/4 HP, 115 V unit on small models to a 400 W, 120 V unit on large ones.
- Bearings and seals are often sold as kits. A water seal has two halves (the stationary part in the evaporator and the
  part that turns with the auger); replace both.
- Check the **refrigerant** on the nameplate: an R-290 (propane) machine needs the maker's own parts (see below).

Type the number into the search box at the top of the page; dashes and spaces don't matter.

## Most-listed augers and gear motors, and prices

| Part number | Brand | Part | Listings | Sellers | Typical price | From | Sold as compatible | Models sellers name |
| --- | --- | --- | ---: | ---: | ---: | ---: | ---: | ---: |
| [120863G02](https://icepartsdb.com/hoshizaki/augers/120863g02) | Hoshizaki | Auger | 16 | 10 | $325 | $200 | 0% | — |
| [A38071-022](https://icepartsdb.com/scotsman/augers/a38071-022) | Scotsman | Auger | 9 | 9 | $870 | $625 | 11% | — |
| [269910G01](https://icepartsdb.com/hoshizaki/augers/269910g01) | Hoshizaki | Auger | 7 | 7 | $495 | $300 | 0% | — |
| [339192G01](https://icepartsdb.com/hoshizaki/augers/339192g01) | Hoshizaki | Auger | 7 | 7 | $99.50 | $72.00 | 0% | 1 |
| [A32900-020](https://icepartsdb.com/scotsman/augers/a32900-020) | Scotsman | Auger | 7 | 5 | $300 | $250 | 0% | — |
| [02-4591-21](https://icepartsdb.com/scotsman/augers/02-4591-21) | Scotsman | Auger | 6 | 6 | $918 | $700 | 17% | — |
| [327141G03](https://icepartsdb.com/hoshizaki/augers/327141g03) | Hoshizaki | Auger | 6 | 5 | $411 | $319 | 17% | — |
| [364141G03](https://icepartsdb.com/hoshizaki/augers/364141g03) | Hoshizaki | Auger | 6 | 6 | $365 | $200 | 17% | — |
| [4301913](https://icepartsdb.com/manitowoc/augers/4301913) | Manitowoc | Auger | 6 | 6 | $71.21 | $29.99 | 0% | — |
| [000002203](https://icepartsdb.com/manitowoc/augers/000002203) | Manitowoc | Auger | 5 | 5 | $61.63 | $38.64 | 20% | — |

Live eBay listings that ship to the US, prices including stated shipping, checked 2026-11-24. Typical price is the median of a part's listings; "sold as compatible" is the share of its listings that say compatible, replacement for or fits. All augers we track: [Hoshizaki (13)](https://icepartsdb.com/hoshizaki/augers) · [Manitowoc (4)](https://icepartsdb.com/manitowoc/augers) · [Scotsman (8)](https://icepartsdb.com/scotsman/augers).

| Part number | Brand | Part | Listings | Sellers | Typical price | From | Sold as compatible |
| --- | --- | --- | ---: | ---: | ---: | ---: | ---: |
| [02-4580-23](https://icepartsdb.com/scotsman/gear-motors/02-4580-23) | Scotsman | Gear Motor | 10 | 9 | $2,085 | $875 | 0% |
| [3A6786-01](https://icepartsdb.com/hoshizaki/gear-motors/3a6786-01) | Hoshizaki | Gear Motor | 8 | 7 | $261 | $100 | 13% |
| [12-2430-21](https://icepartsdb.com/scotsman/gear-motors/12-2430-21) | Scotsman | Gear Motor | 6 | 5 | $1,079 | $942 | 33% |
| [12-2677-21](https://icepartsdb.com/scotsman/gear-motors/12-2677-21) | Scotsman | Gear Motor | 6 | 6 | $943 | $325 | 0% |
| [4A5650-01](https://icepartsdb.com/hoshizaki/gear-motors/4a5650-01) | Hoshizaki | Gear Motor | 6 | 6 | $1,956 | $340 | 17% |
| [000011126](https://icepartsdb.com/manitowoc/gear-motors/000011126) | Manitowoc | Gear Motor | 5 | 5 | $3,120 | $500 | 20% |
| [12-3083-21](https://icepartsdb.com/scotsman/gear-motors/12-3083-21) | Scotsman | Gear Motor | 5 | 5 | $1,740 | $895 | 20% |
| [3A6786-02](https://icepartsdb.com/hoshizaki/gear-motors/3a6786-02) | Hoshizaki | Gear Motor | 5 | 4 | $299 | $100 | 20% |
| [4A5855-01](https://icepartsdb.com/hoshizaki/gear-motors/4a5855-01) | Hoshizaki | Gear Motor | 5 | 3 | $1,260 | $340 | 20% |
| [12-1610-01](https://icepartsdb.com/scotsman/gear-motors/12-1610-01) | Scotsman | Gear Motor | 4 | 4 | $147 | $65.00 | 0% |

Live eBay listings that ship to the US, prices including stated shipping, checked 2026-11-24. Typical price is the median of a part's listings; "sold as compatible" is the share of its listings that say compatible, replacement for or fits. All gear motors we track: [Hoshizaki (7)](https://icepartsdb.com/hoshizaki/gear-motors) · [Manitowoc (1)](https://icepartsdb.com/manitowoc/gear-motors) · [Scotsman (8)](https://icepartsdb.com/scotsman/gear-motors).

- [Hoshizaki augers](https://icepartsdb.com/hoshizaki/augers): 13 part numbers · 75 listings · typical $411
- [Manitowoc augers](https://icepartsdb.com/manitowoc/augers): 4 part numbers · 18 listings · typical $71.21
- [Scotsman augers](https://icepartsdb.com/scotsman/augers): 8 part numbers · 46 listings · typical $870

- [Hoshizaki gear motors](https://icepartsdb.com/hoshizaki/gear-motors): 7 part numbers · 33 listings · typical $603
- [Manitowoc gear motors](https://icepartsdb.com/manitowoc/gear-motors): 1 part numbers · 5 listings
- [Scotsman gear motors](https://icepartsdb.com/scotsman/gear-motors): 8 part numbers · 41 listings · typical $1,740

## OEM or compatible?

| Part type | Listings | Sold as compatible / aftermarket | Median, OEM or not stated | Median, compatible / aftermarket | Difference |
| --- | ---: | ---: | ---: | ---: | ---: |
| Gear Motors | 77 | 12% | $942 | $1,593 | 69% more |

Active eBay part listings for Hoshizaki, Manitowoc and Scotsman parts that ship to the US, totals including stated shipping. "Compatible / aftermarket" means the title says so (compatible, replacement for, fits …); the rest say OEM or don't say. Multi-packs are left out, and a median is shown only with at least 8 listings on that side.

The auger, bearings and seals are made to fit each evaporator, and an auger that rubs the evaporator wall damages both
(Scotsman says an auger that has touched the wall should be replaced). For these parts the maker's own, or a compatible
part from a supplier you trust that lists the exact OEM number, is the safer choice. On R-290 (propane) machines use
only the maker's part: Manitowoc requires like components from its authorized parts network, and Scotsman parts it
specifies, because others can ignite leaking refrigerant. See
[OEM vs aftermarket parts](https://icepartsdb.com/guides/oem-vs-aftermarket-ice-machine-parts).

## Replacing an auger, bearing, seal or gear motor

This is work for a trained technician: the evaporator has to come apart, seals are single-use, and Scotsman says even
the top bearing check should be done only by a qualified service technician. On an R-290 (propane) machine (see the
nameplate), it must be a technician trained for flammable refrigerants; Manitowoc allows only such technicians to work
on its R-290 machines. Replacing the evaporator itself means recovering the refrigerant, which is work for an EPA
Section 608 certified technician on R-404A machines. See
[ice machine refrigerants and the EPA rules](https://icepartsdb.com/guides/ice-machine-refrigerant-r290-epa-rules) and the
[safety notes](https://icepartsdb.com/legal/safety-disclaimer). The outline, from Scotsman's procedures:

1. Switch the machine off, then switch off and lock out its power supply disconnect; shut off the water and drain the
   reservoir and evaporator.
2. Remove the ice chute, sweep and breaker or extruding head, then lift out the auger.
3. To replace the water seal, separate the evaporator from the gear reducer, remove the old seal halves, seal the new
   rotating half to the auger with food-grade sealant (keeping sealant off the seal face) and fit the stationary half.
4. To replace the gear reducer, with the auger and water seal out and the evaporator lifted off, disconnect the drive
   motor's wiring and unbolt the reducer from the machine; Scotsman bench-tests a rebuilt reducer for oil leaks, noise
   and amp draw.
5. Reassemble, descale and sanitize, and run the machine, checking for leaks, noise and normal auger motor current.

While it is apart, descale the auger and the inside of the evaporator: Scotsman uses ice machine cleaner and a nylon
scrub pad on the auger, and a brass wire brush, scrubbed vertically, inside the evaporator.

## Questions and answers

### Why is my flake or nugget ice machine making a loud noise?

A slight crunching as ice is forced through the breaker or extruding head is normal. Scotsman says a loud moaning noise
can come from a "rotating freeze", most likely caused by scale on the auger: the ice stops sliding up the evaporator,
turns with the auger, hardens and overloads the gear reducer. Have the machine descaled and the top bearing checked. If the moaning
continues, Scotsman points to a failing gear reducer bearing.

### How often should the bearings be checked on a nugget ice machine?

Scotsman says at least twice a year, or every time the machine is descaled. Hoshizaki's flaker manual calls for a
yearly upper bearing check, and from the third year a yearly inspection of both bearings, the mechanical seal, the auger
and the evaporator cylinder.

### What does an auger overload error mean?

The auger motor is drawing too much current because the auger is hard to turn: scale on the auger and evaporator,
worn bearings, a damaged gear reducer or a restriction in the water supply to the evaporator. On Scotsman's Prodigy flake
and nugget machines it is code 2 (flashing while it retries after 4 minutes, steady once it has shut down). Scotsman's
HID dispensers and UF/UN X undercounters use 2 for an auger stalled or turning too slowly and 1 for one turning
backwards. Hoshizaki's modular flakers beep 8 times when the gear motor circuit fails, which includes the motor's
protector tripping. Find the cause before resetting, or it will trip again.

### Why is there water in the drip pan of my flaker?

The water seal (or mechanical seal) where the auger leaves the evaporator is leaking. Have it replaced, and have the
gear reducer's oil checked, because water that gets past the seal can reach the gears.

### How much does an ice machine auger or gear motor cost?

Augers and auger parts for Hoshizaki, Manitowoc and Scotsman flake and nugget machines sell for
mostly $250 to $940 (median $553, from 132 live eBay listings including shipping, checked 2026-11-24); gear motors sell for mostly $340 to $2,055 (median $1,010, from 77 live eBay listings including shipping, checked 2026-11-24). Bearings, seals and the
labor to fit them come on top, so have the bearings checked on schedule before a worn one damages the auger.

### Can I replace just the gear motor?

Often, yes. On Scotsman's Prodigy flakers the drive motor comes off the gear reducer on its own (Scotsman removes it to
check the reducer's oil). Replacing the gear reducer is a bigger job: the auger and water seal come out and the
evaporator is lifted off first. If water got past the seal into the gears, replace the seal too, or the new drive will
be damaged the same way.

## Sources

- Scotsman Ice Systems, [*Prodigy Flaked and Nugget Ice Machines Service Manual*](https://www.scotsman-ice.com/service/Service%20Manuals/PF_awr_Service_Manual.pdf),
  models F0522 to F1522 and N0422 to N1322, December 2014 (diagnostic pages revised May 2017): electrical components
  and auger motor (page 23), evaporator (page 24), sequence of operation, no-ice and auger overload codes (page 25), how
  ice is made (page 31), auger drive specifications (page 32), maintenance and top bearing check (pages 35–39),
  diagnostics (pages 40–42), breaker bearing, auger, evaporator, water seal and gear reducer repair procedures
  (pages 48–52).
- Scotsman Ice Systems, [*Service Manual for Modular Flake and Nugget Ice Machines NH0422X to FS1522X*](https://www.scotsman-ice.com/service/Service%20Manuals/Prodigy%20Solid%20Lube%20FN%20Service%20Man,%20AWRX.pdf),
  April 2025: flammable refrigerant safety information and replacement parts (page 5), gear reducer lubricant check
  (page 39).
- Scotsman Ice Systems, [*Technical Manual for Model UF424X and UN324X*](https://www.scotsman-ice.com/service/Service%20Manuals/UFUN24X_svc.pdf),
  October 2025: normal sounds and rotating freeze (page 16), moaning noise diagnosis (page 17).
- Scotsman Ice Systems, [*Service Manual for Meridian Ice Maker-Dispensers HID312X, HID525X and HID540X*](https://www.scotsman-ice.com/service/Service%20Manuals/HIDXService.pdf),
  June 2025: replace the top bearing, bottom bearing and water seal together (page 36).
- Scotsman Ice Systems, [*Service Manual for Modular Flake and Nugget Ice Machines FS2330, NH2030 and NS2030*](https://www.scotsman-ice.com/service/Service%20Manuals/FS2330WR.pdf),
  November 2022: change both top and bottom bearings if one must be changed (page 40).
- Hoshizaki America, *Modular Flaker Instruction Manual* (F-450MAJ, F-801M_J, F-1002M_J, F-1501M_J, F-2001M_J,
  FD-650M_J-C, FD-1002M_J-C), issued 7-27-2017, revised 5-30-2018: electrical data (gear motors, pages 7–10), alarm
  safeties (page 42), maintenance schedule (page 44),
  [copy hosted by WebstaurantStore](https://argo.webstaurantstore.com/documents/pdf/415f1002mrjx_manual.pdf).
- Hoshizaki America, *FS-1022MLH-C Modular Cubelet Service Manual* No. 73186, issued 6-9-2011: 8-beep gear motor alarm
  (page 18), no-ice diagnosis for the gear motor and its protect relay (pages 38–39).
- Manitowoc Ice, [*Indigo NXT Air/Water/Remote Condenser Ice Machines Technician's Handbook*](https://www.manitowocice.com/asset/?id=ebxvra),
  Part Number 000018553 Rev 00 04/26: R-290 safety notices (pages 9–10).

## More guides

- [Ice machine not making ice? Causes, checks and the parts that fix them](https://icepartsdb.com/guides/ice-machine-not-making-ice)
- [Hoshizaki ice machine beeping? What 1, 2, 3, 6 and 7 beeps mean (error codes)](https://icepartsdb.com/guides/hoshizaki-ice-machine-error-codes)
- [Manitowoc ice machine error codes (Indigo NXT E01 to E31): meanings and fixes](https://icepartsdb.com/guides/manitowoc-ice-machine-error-codes)
- [Scotsman ice machine error codes: Prodigy code display meanings and fixes](https://icepartsdb.com/guides/scotsman-ice-machine-error-codes)
- [Ice-O-Matic ice machine error codes: CIM flashing lights, GEM and MFI service lights](https://icepartsdb.com/guides/ice-o-matic-ice-machine-error-codes)
- [How to reset a commercial ice machine (Hoshizaki, Manitowoc, Scotsman, Ice-O-Matic)](https://icepartsdb.com/guides/how-to-reset-commercial-ice-machine)
- [Ice machine water inlet valve: symptoms, testing and replacement](https://icepartsdb.com/guides/ice-machine-water-inlet-valve)
- [Ice machine water pump: symptoms, testing and replacement](https://icepartsdb.com/guides/ice-machine-water-pump)

## Data sources

- eBay listings (Browse API search results) — part numbers, listing counts and prices
- [How we build these pages (methodology)](https://icepartsdb.com/legal/editorial-policy)

Last updated: 2026-11-22

Canonical URL: https://icepartsdb.com/guides/ice-machine-auger-gear-motor