# Ice thickness probe and thermistor: how ice machines decide when to harvest

Last updated 2026-11-22

**Short answer:** A cube machine has to know when the ice is ready to harvest and when the harvest is over, and the three makers do it differently. Manitowoc and Scotsman Prodigy cubers start the harvest with an ice thickness probe set a small gap from the evaporator, and end it when the falling sheet of ice swings the water curtain open. Hoshizaki crescent cubers end the freeze with the float switch, when the water level in the tank drops, and end the harvest with a thermistor on the evaporator outlet line plus a timer. Thermistors on all three brands also watch refrigerant and water temperatures for safeties and diagnostics. A dirty, misadjusted or failed sensor gives thin or thick cubes, a slab that won't release, or a lockout; clean and check the adjustment first, and replace it by the number on the old part.

**Safety:** Disconnect power before servicing, and follow the manufacturer's service manual. Refrigerant work is for a qualified refrigeration technician (EPA Section 608 certified; trained for flammable refrigerants on R-290 machines), electrical work for a qualified person. Safety disclaimer: https://icepartsdb.com/legal/safety-disclaimer

## How an ice machine decides when to harvest

A cube machine freezes ice on its evaporator until the cubes are the right size, then switches to harvest: hot gas
warms the evaporator so the ice releases, and the machine goes back to freezing once the ice has dropped. Two decisions
make even, full cubes: when to end the freeze, and when to end the harvest.

| | Ends the freeze (starts the harvest) | Ends the harvest |
| --- | --- | --- |
| Manitowoc cubers | Ice thickness probe, after a 6-minute freeze lock | Bin switch: the falling ice swings the water curtain open, and it closes again within 30 seconds |
| Scotsman Prodigy cubers | Ice thickness sensor: water touching it for a few seconds | Curtain switch: the falling ice forces the curtain open |
| Hoshizaki crescent cubers | Float switch: the water level in the tank drops as water turns to ice (after a 5-minute minimum) | Thermistor on the evaporator outlet line reaches 48 °F, then the harvest timer (60 to 180 seconds) runs out |

Every maker also has backstops: a maximum freeze time (for example 35 minutes on the Manitowoc Indigo NXT) and a
maximum harvest time, and the machine locks out if they keep running out.

**Ice thickness probe (Manitowoc, Scotsman Prodigy).** A small probe on a bracket, held a set gap from the evaporator.
On Scotsman Prodigy cubers and older Manitowoc machines (the S model, for example) it is a conductivity sensor: as the
ice grows, the water running over it reaches the probe tip, and when it touches for a few continuous seconds (about 10
seconds on the Manitowoc S model) the board starts the harvest. The probe on the current Manitowoc Indigo NXT works
differently: it senses the ice acoustically, comparing what it picks up with baseline readings taken in the first 6
minutes of the freeze, and Manitowoc tests it with a tap test on the probe tip. Either way, the gap sets the ice bridge
(the thin layer that joins the cubes).

**Thermistor.** A resistor whose resistance changes with temperature, clipped to a refrigerant line or set in a water
line. On a Hoshizaki crescent cuber the thermistor on the suction line at the evaporator outlet controls the harvest:
at 48 °F (the board reads 3.9 kΩ) it hands the end of the harvest to the timer. The same thermistor stops the pump for
10 seconds early in the freeze (at 36 °F) and triggers the 1-beep alarm if the evaporator goes above 127 °F. Manitowoc
Indigo NXT machines have four thermistors, T1 to T4 (on single-circuit models: condenser liquid line, compressor
discharge, evaporator inlet and evaporator outlet), which the board uses for its alerts and diagnostics. Scotsman Prodigy cubers have a water temperature sensor in the pump
discharge hose (it times the 30-second anti-slush pause) and a discharge temperature sensor near the compressor (it
shuts the machine off if the discharge gets too hot).

The parts manual shows which sensors your machine has. Undercounter models can work differently again: Scotsman's
CU0415X to CU0920X, for example, end both the freeze and the harvest on thermistor readings plus timers.

## Signs the probe or thermistor is failing

| What you see | Likely cause |
| --- | --- |
| Thin, small or hollow cubes (Manitowoc, Scotsman) | Freeze ends too early: probe set too close, scale or slime on the probe, uneven water flow reaching it early |
| Thick cubes, or cubes joined into a slab (Manitowoc, Scotsman) | Freeze ends too late: probe set too far away, or a failed probe |
| The machine never harvests and freezes into a block | No harvest signal: failed or disconnected probe, broken wire; on a Hoshizaki, a stuck float switch |
| Long harvests or a long-harvest lockout | Hoshizaki: an open thermistor (2-beep alarm); Manitowoc and Scotsman: a curtain that doesn't swing or a failed curtain or bin switch; any brand: scale, a hot gas valve that doesn't open |
| A sensor fault code; the machine runs in a default mode | Open or shorted thermistor, or a corroded connector (Scotsman codes 5 and 7; Manitowoc T1 to T4 alerts) |

For cube size problems in general, see
[small, thin, thick or cloudy cubes](https://icepartsdb.com/guides/ice-machine-not-making-ice#small-thin-thick-or-cloudy-cubes). For codes, see
the [Hoshizaki](https://icepartsdb.com/guides/hoshizaki-ice-machine-error-codes), [Manitowoc](https://icepartsdb.com/guides/manitowoc-ice-machine-error-codes),
[Scotsman](https://icepartsdb.com/guides/scotsman-ice-machine-error-codes) and [Ice-O-Matic](https://icepartsdb.com/guides/ice-o-matic-ice-machine-error-codes) error code guides; for Hoshizaki float switches, the
[float switch guide](https://icepartsdb.com/guides/ice-machine-float-switch).

## How to check it

Switch off and unplug the machine before reaching inside, unless a step says otherwise.

1. **Clean the ice thickness probe.** Scale on the probe and its insulator changes the bridge thickness. Clean it with
   diluted ice machine cleaner (scale remover) at every cleaning, rinse it and dry it. Manitowoc warns never to put its
   probe in a dishwasher.
2. **Check the gap and the bridge.** Run a freeze cycle and look at a harvested slab. Manitowoc sets its probe for an ice
   bridge of 1/8 inch, starting from a 9/32-inch gap (a drill bit of that size between probe and evaporator); on the
   Indigo NXT, a third of a turn of the adjusting screw changes the bridge by about 1/16 inch, clockwise for thicker.
   Scotsman Prodigy cubers use a 7/32-inch gap for a 1/8 to 3/16-inch bridge, and Scotsman warns that a bridge that is
   too thin stops the machine harvesting properly. Adjust with the machine off, in small steps, and check a full batch
   each time.
3. **Check the water flow.** Uneven water over the evaporator can reach a conductivity probe early; Scotsman's fix is to
   scrub the spillway at the top of the evaporator.
4. **Test a thermistor.** Unplug it and compare its resistance with the maker's figure at a known temperature.
   Hoshizaki: remove the thermistor, hold its tip in ice water for 2 to 3 minutes, and expect 4.7 to 6.2 kΩ. Scotsman
   Prodigy: in ice water at 32 °F, within 1,000 ohms of 32,649. Manitowoc Indigo NXT: within 10% of the chart value
   for the measured temperature. A reading of zero (short) or no reading (open) means it has failed.
5. **Check the wiring.** A broken wire or corroded connector looks like a failed sensor.

## Finding the right part number

- Read the number on the sensor's wire tag or in the parts manual
  ([how to find the model and part number](https://icepartsdb.com/guides/find-ice-machine-model-number-and-part-number)). Probes differ in
  shape, mounting bracket and cable length between machine series, and an Indigo NXT probe is a different kind of
  sensor from the conductivity probes in older Manitowoc machines.
- Makers update probe numbers over time; "replaces …" in a listing usually covers the old number.
- Thermistors differ in resistance curve as well as fitting (compare Hoshizaki's 4.7 to 6.2 kΩ at 32 °F with
  Scotsman's 32,649 ohms), so a thermistor from another machine may read wrongly even if it fits.

Type the number into the search box at the top of the page; dashes and spaces don't matter.

## Most-listed ice thickness probes, thermistors and sensors

| Part number | Brand | Part | Listings | Sellers | Typical price | From | Sold as compatible | Models sellers name |
| --- | --- | --- | ---: | ---: | ---: | ---: | ---: | ---: |
| [000008660](https://icepartsdb.com/manitowoc/thermistors-sensors/000008660) | Manitowoc | Sensor | 119 | 59 | $25.99 | $23.59 | 89% | — |
| [11-0515-21](https://icepartsdb.com/scotsman/thermistors-sensors/11-0515-21) | Scotsman | Sensor | 30 | 27 | $26.71 | $16.69 | 67% | 17 |
| [000015573](https://icepartsdb.com/manitowoc/thermistors-sensors/000015573) | Manitowoc | Sensor | 29 | 28 | $35.00 | $19.99 | 3% | — |
| [2008029](https://icepartsdb.com/manitowoc/thermistors-sensors/2008029) | Manitowoc | Sensor | 27 | 23 | $32.96 | $17.89 | 26% | — |
| [A39031-021](https://icepartsdb.com/scotsman/thermistors-sensors/a39031-021) | Scotsman | Sensor | 20 | 12 | $35.94 | $19.99 | 65% | — |
| [7627813](https://icepartsdb.com/manitowoc/thermistors-sensors/7627813) | Manitowoc | Sensor | 19 | 16 | $23.78 | $16.31 | 58% | — |
| [02-3410-21](https://icepartsdb.com/scotsman/thermistors-sensors/02-3410-21) | Scotsman | Sensor | 16 | 14 | $115 | $49.50 | 44% | — |
| [11-0577-01](https://icepartsdb.com/scotsman/thermistors-sensors/11-0577-01) | Scotsman | Sensor | 14 | 14 | $53.17 | $29.85 | 43% | — |
| [11-0545-21](https://icepartsdb.com/scotsman/thermistors-sensors/11-0545-21) | Scotsman | Sensor | 11 | 11 | $128 | $50.19 | 36% | — |
| [429006-03](https://icepartsdb.com/hoshizaki/thermistors-sensors/429006-03) | Hoshizaki | Sensor | 10 | 8 | $51.49 | $34.80 | 70% | 20 |
| [437626-01](https://icepartsdb.com/hoshizaki/thermistors-sensors/437626-01) | Hoshizaki | Sensor | 10 | 8 | $103 | $39.00 | 30% | — |
| [2009853](https://icepartsdb.com/manitowoc/thermistors-sensors/2009853) | Manitowoc | Sensor | 9 | 9 | $33.54 | $25.94 | 11% | — |

Live eBay listings that ship to the US, prices including stated shipping, checked 2026-11-24. Typical price is the median of a part's listings; "sold as compatible" is the share of its listings that say compatible, replacement for or fits. All thermistors & sensors we track: [Hoshizaki (12)](https://icepartsdb.com/hoshizaki/thermistors-sensors) · [Manitowoc (17)](https://icepartsdb.com/manitowoc/thermistors-sensors) · [Scotsman (23)](https://icepartsdb.com/scotsman/thermistors-sensors).

- [Hoshizaki thermistors & sensors](https://icepartsdb.com/hoshizaki/thermistors-sensors): 12 part numbers · 79 listings · typical $53.00
- [Manitowoc thermistors & sensors](https://icepartsdb.com/manitowoc/thermistors-sensors): 17 part numbers · 268 listings · typical $25.99
- [Scotsman thermistors & sensors](https://icepartsdb.com/scotsman/thermistors-sensors): 23 part numbers · 186 listings · typical $115

## OEM or compatible?

| Part type | Listings | Sold as compatible / aftermarket | Median, OEM or not stated | Median, compatible / aftermarket | Difference |
| --- | ---: | ---: | ---: | ---: | ---: |
| Thermistors & Sensors | 500 | 43% | $87.99 | $31.89 | 64% less |

Active eBay part listings for Hoshizaki, Manitowoc and Scotsman parts that ship to the US, totals including stated shipping. "Compatible / aftermarket" means the title says so (compatible, replacement for, fits …); the rest say OEM or don't say. Multi-packs are left out, and a median is shown only with at least 8 listings on that side.

The table shows the current share of compatible listings and the median price of each kind. See
[OEM vs aftermarket ice machine parts](https://icepartsdb.com/guides/oem-vs-aftermarket-ice-machine-parts).

## Replacing a probe or thermistor

1. Switch off and unplug the machine.
2. Unplug the sensor from the control board, noting the connector. On Hoshizaki boards the thermistor and the float
   switch use the same type of connector, so don't swap them.
3. Remove it from its bracket (a probe) or from the refrigerant line (a thermistor, usually held by a holder or clip
   and covered with insulation).
4. Fit the new one in the same position. For a probe, set the gap to the manual's figure. For a Hoshizaki thermistor,
   Hoshizaki says to fit it at the same spot on the suction line, at the 12 o'clock position, fill the holder with heat
   sink compound, then secure it with the holder and insulate it.
5. Run a full cycle and check the cube size and the harvest.

## Questions and answers

### What does an ice thickness probe do?

It ends the freeze and starts the harvest when the ice on the evaporator is thick enough. On Scotsman Prodigy and older
Manitowoc cubers, the water flowing over the ice touches the probe for a few seconds and the board switches to harvest;
the Manitowoc Indigo NXT probe senses the ice acoustically instead. Hoshizaki crescent cubers have no ice thickness probe:
their float switch ends the freeze.

### How do I adjust the ice thickness probe on a Manitowoc ice machine?

Turn the probe's adjusting screw, with the machine off: clockwise for a thicker bridge, counterclockwise for a thinner
one. Manitowoc's target is an ice bridge of about 1/8 inch, starting from a 9/32-inch gap between probe and evaporator;
on the Indigo NXT, a third of a turn changes the bridge by about 1/16 inch. Check a full batch after each adjustment.

### Why is my ice machine making thin cubes?

The freeze is ending too early, or too little water is flowing over the evaporator. The full checklist is in the
[not making ice guide](https://icepartsdb.com/guides/ice-machine-not-making-ice#small-thin-thick-or-cloudy-cubes); for the probe itself, clean
it and check its gap first.

### What does a thermistor do in an ice machine?

It measures temperature. On a Hoshizaki crescent cuber the evaporator outlet thermistor tells the board when the
evaporator has warmed to 48 °F during the harvest, after which a timer ends the harvest; it also drives a high
temperature alarm. On Manitowoc and Scotsman cubers, thermistors watch refrigerant and water temperatures for safeties,
diagnostics and the pump's anti-slush pause, while the ice thickness probe and the curtain switch control the cycle.

### What does the thermistor do on a Hoshizaki ice machine?

It tells the control board the evaporator's temperature. Clipped to the suction line at the evaporator outlet, it hands
the end of the harvest to the timer once it reaches 48 °F, stops the water pump briefly early in the freeze, and sets
off the 1-beep alarm if the evaporator goes above 127 °F. A failed (open) thermistor gives long harvests and the 2-beep
alarm.

### How do I test a Hoshizaki thermistor?

Unplug it from the control board, take it off the suction line, hold the sensing end in a glass of ice water for 2 to 3
minutes and measure the resistance between its leads. Hoshizaki gives 4.7 to 6.2 kΩ as normal; outside that range,
replace it.

### How much does an ice thickness probe cost?

Live eBay prices for ice thickness probes, thermistors and other sensors for Hoshizaki, Manitowoc and Scotsman machines
are mostly $28.90 to $125 (median $52.99, from 500 live eBay listings including shipping, checked 2026-11-24). The tables above break this down by part number and brand.

## Sources

- Hoshizaki America, *KML-325MAJ/MWJ, KML-500MAJ/MWJ, KML-700MAJ/MWJ/MRJ Modular Crescent Cuber Service Manual*,
  No. 73215, issued 6-16-2017: sequence of operation (pages 13–19), thermistor check (page 27), control board connectors
  (page 33), alarms (page 34), harvest timer (page 35), thermistor replacement (page 43).
- Hoshizaki America, *KM-1100MAJ50 Modular Crescent Cuber Service Manual*, No. 73231, issued 9-12-2018: sequence of
  operation (pages 12–15).
- Hoshizaki America, *KM-2500SWH3, KM-2500SRH3 Stackable Crescent Cuber Service Manual*, No. 73164, issued 6-10-2010:
  connector caution (page 15).
- Manitowoc Ice, [*Indigo NXT Air/Water/Remote Condenser Ice Machines Technician's Handbook*](https://www.manitowocice.com/asset/?id=ebxvra),
  Part Number 000018553 Rev 00 04/26: probe cleaning (page 50), ice thickness check (pages 70 and 162), control board
  timers (page 71), sequence of operation (pages 72–75), bin switch (page 150), ice thickness probe and diagnostics
  (pages 161–165), thermistors (pages 170–173).
- Manitowoc Ice, [*S Model Air/Water/Remote Ice Machines Technician's Handbook*](https://www.manitowocice.com/asset/?id=hgney),
  Part Number 8014793, 6/18: freeze sequence and ice thickness probe (page 50).
- Scotsman Ice Systems, [*Prodigy Series Modular Cuber Technical Service Manual*](https://www.scotsman-ice.com/service/Service%20Manuals/Service%20manual.pdf),
  January 2015: ice bridge thickness (page 7), system information (page 15), how it works (page 18), temperature sensors
  (pages 25–26 and 55), ice thickness sensor and spillway (pages 41–42).
- Scotsman Ice Systems, *Service Manual for Cube Ice Machine with Storage, Models CU0415X, CU0715X and CU0920X*, July
  2025: sequence of operation.

## More guides

- [Ice machine not making ice? Causes, checks and the parts that fix them](https://icepartsdb.com/guides/ice-machine-not-making-ice)
- [Hoshizaki ice machine beeping? What 1, 2, 3, 6 and 7 beeps mean (error codes)](https://icepartsdb.com/guides/hoshizaki-ice-machine-error-codes)
- [Manitowoc ice machine error codes (Indigo NXT E01 to E31): meanings and fixes](https://icepartsdb.com/guides/manitowoc-ice-machine-error-codes)
- [Scotsman ice machine error codes: Prodigy code display meanings and fixes](https://icepartsdb.com/guides/scotsman-ice-machine-error-codes)
- [Ice-O-Matic ice machine error codes: CIM flashing lights, GEM and MFI service lights](https://icepartsdb.com/guides/ice-o-matic-ice-machine-error-codes)
- [How to reset a commercial ice machine (Hoshizaki, Manitowoc, Scotsman, Ice-O-Matic)](https://icepartsdb.com/guides/how-to-reset-commercial-ice-machine)
- [Ice machine water inlet valve: symptoms, testing and replacement](https://icepartsdb.com/guides/ice-machine-water-inlet-valve)
- [Ice machine water pump: symptoms, testing and replacement](https://icepartsdb.com/guides/ice-machine-water-pump)

## Data sources

- eBay listings (Browse API search results) — part numbers, listing counts and prices
- [How we build these pages (methodology)](https://icepartsdb.com/legal/editorial-policy)

Last updated: 2026-11-22

Canonical URL: https://icepartsdb.com/guides/ice-machine-thermistor-sensor

Report a correction to this page: https://icepartsdb.com/contact/correction?page=%2Fguides%2Fice-machine-thermistor-sensor