# Manitowoc ice machine error codes (Indigo NXT E01 to E31): meanings and fixes

Last updated 2026-11-21

**Short answer:** Indigo NXT machines show an alert icon on the touchscreen; tap it to open the alert log, where each alert has a short text and an E code. The two that shut the machine down until someone restarts it are E01 Long Freeze (the freeze cycle reached 35 minutes three cycles in a row) and E02 Long Harvest (the harvest reached 7 minutes three cycles in a row). Restart with the green power button or by switching the power off and on, at most three times in 24 hours, and find the cause first. E05 (high pressure cut-out) stops the machine for 10 minutes before it retries; most other codes point to a sensor, the water system or the refrigeration system.

**Safety:** Disconnect power before servicing, and follow the manufacturer's service manual. Refrigerant work is for a qualified refrigeration technician (EPA Section 608 certified; trained for flammable refrigerants on R-290 machines), electrical work for a qualified person. Safety disclaimer: https://icepartsdb.com/legal/safety-disclaimer

This guide covers the Manitowoc Indigo NXT ice machines (the IYT, IDT, IYF, IDF, IRT and related models, and the R290
models IYP, IDP and IRP), from Manitowoc's Indigo NXT technician's handbook. For any other Manitowoc series, use the
technician's handbook for that series.

**Safety first.** The machine's power switch does **not** disconnect all incoming power: switch off and lock out the main
power supply disconnect before any work inside. R290 (propane) models contain a flammable refrigerant; only refrigeration
technicians trained for flammable refrigerants may work on their refrigeration system, and Manitowoc requires their
replacement parts to come from its authorized parts network. Other refrigeration work needs a technician certified under
EPA Section 608.

## How to read alerts on an Indigo NXT

- An **alert icon with a number** appears on the touchscreen when there are alerts. Tap it to open the **alert log**,
  where you can read and clear them. The log is also in the service menu ("Alert Log: lists/clears alerts").
- The data history in the same menu shows minimum and maximum freeze and harvest times, which helps when a fault comes
  and goes.
- If the machine shuts down on Long Freeze or Long Harvest, a **green power button** appears on the display.
- Manitowoc advises resetting the control board to factory defaults before troubleshooting, after writing down (or
  copying to USB) any customer settings, so a changed setting isn't mistaken for a fault.

## Every Indigo NXT alert code

| Display text | Code | Meaning | What triggers it |
| --- | --- | --- | --- |
| Long Freeze | E01 | Long freeze cycle | The freeze cycle reaches 35 minutes three cycles in a row (each 35-minute freeze is ended by a forced harvest); the machine shuts down |
| Long Harvest | E02 | Long harvest cycle | The harvest reaches 7 minutes three cycles in a row (each one is followed by a thaw cycle); the machine shuts down |
| Power Loss | E03 | Input power loss | Power to the machine was interrupted; logged when it comes back |
| Hi cnd Temp / Wtr Cnd Fault | E04 | High condenser temperature | The liquid line temperature is too high for an air-cooled or water-cooled self-contained machine |
| HPC Fault | E05 | High pressure control opened | The high pressure cut-out switch opened: the machine stops, waits 10 minutes and tries again, repeating while the switch stays open |
| Starving TXV | E07 | Starving expansion valve or low charge (single evaporator) | Evaporator inlet and outlet temperatures differ by more than 12 °F in the last minute of the freeze cycle |
| TXV Fault | E08 | Expansion valve fault (single or dual circuit evaporators) | The same temperature-difference test as E07 |
| Flood Evap1 | E09 | Flooding evaporator, single evaporator, single circuit | The compressor discharge temperature in the first 6 minutes of the freeze cycle doesn't rise far enough above the pre-chill reading |
| Flood Evap2 | E10 | Flooding evaporator, dual expansion valve, dual circuit | The same test as E09 |
| Refrig Fault | E11 | Refrigeration fault | From start-up to 2 minutes into the freeze cycle, the discharge temperature didn't rise by 10 °F and the evaporator temperature didn't fall by 10 °F |
| Curtain Fault | E12 | Curtain switch open more than 24 hours | The machine is set to make ice but has read "bin full" for over 24 hours: curtain open or off |
| Low liq temp | E15 | Fan cycle control fault | The liquid line stays below 60 °F for more than a minute during freeze |
| Rmt Cnd Fault | E16 | Remote condensing unit fault | Remote condensing (CVD) models only: the liquid line goes below 40 °F or above 140 °F for over a minute during freeze |
| ITP Fault | E19 | Ice thickness probe fault | The probe's signal is out of range (unplugged or failed) |
| WTR Fault | E20 | Water system fault | The high water probe senses water but the low one doesn't; or the evaporator outlet is below −10 °F 6.5–7.5 minutes into freeze; or the low water probe still senses water at the end of harvest |
| T1 to T4 Fault | E21 to E24 | Temperature sensor issue | One of the four temperature sensors (thermistors) reads outside its valid range during pre-chill |
| Bin Probe Fault | E25 | Bin level probe low sensor fault | The bin level sensor reads out of range for 10 minutes |
| iAUCS | E28 | Automatic cleaning system | The iAuCS cleaning option was chosen but its board isn't detected; clears when the hardware is detected |
| Safe Mode | E31 | Safe mode | The machine is running on stored cycle data because the water level or ice thickness probe failed |

The parts behind the most common alerts: [water level probes](https://icepartsdb.com/glossary#water-level-probe) ([Manitowoc](https://icepartsdb.com/manitowoc/float-switches) float switches), [ice thickness probes](https://icepartsdb.com/glossary#ice-thickness-probe)
and thermistors ([Manitowoc](https://icepartsdb.com/manitowoc/thermistors-sensors) thermistors & sensors), [Manitowoc](https://icepartsdb.com/manitowoc/water-inlet-valves) water inlet valves,
[Manitowoc](https://icepartsdb.com/manitowoc/water-pumps) water pumps, [Manitowoc](https://icepartsdb.com/manitowoc/condenser-fan-motors) condenser fan motors, [Manitowoc](https://icepartsdb.com/manitowoc/hot-gas-valves) hot gas valves and
[Manitowoc](https://icepartsdb.com/manitowoc/control-boards) control boards.

## E01 Long Freeze: what to check

Manitowoc says these shutdowns are most often caused by a minor problem or something outside the machine, often
intermittent: a cold room at night, a drop in water pressure, water turned off one night a week. Rule out external and
electrical causes before the refrigeration system. Its checklist:

- **Installation:** work through the installation and visual inspection checklist in the handbook.
- **Water:** pressure between 20 and 80 psi, inlet water no warmer than 90 °F, a clean water distribution tube, a working
  water fill valve, [dump valve](https://icepartsdb.com/glossary#dump-valve) and water pump, no water lost from the [sump](https://icepartsdb.com/glossary#sump), and a clean, working water level probe. See
  the [water inlet valve](https://icepartsdb.com/guides/ice-machine-water-inlet-valve) and [water pump](https://icepartsdb.com/guides/ice-machine-water-pump) guides.
- **Electrical:** low incoming voltage, an ice thickness probe out of adjustment (see the
  [ice thickness probe guide](https://icepartsdb.com/guides/ice-machine-thermistor-sensor)), a harvest that isn't started electrically, a
  contactor that doesn't energize, a compressor that doesn't run electrically, a failed fan cycling control or fan motor.
- **Air and heat:** dirty condenser fins or restricted airflow, hot inlet air, or discharge air recirculating to the
  condenser.
- **Refrigeration (technician):** non-Manitowoc components, wrong refrigerant charge, non-condensables in the system,
  restricted high-side lines, a failed [head pressure control](https://icepartsdb.com/glossary#headmaster), harvest valve or compressor, an [expansion valve](https://icepartsdb.com/glossary#expansion-valve) starving or
  flooding.

## E02 Long Harvest: what to check

- **Water and scale:** a dirty evaporator, a dump valve that doesn't work, the drain vent tube missing, water freezing
  behind the evaporator, loose plastic extrusions or gaskets on the evaporator, a clogged distribution tube.
- **Electrical:** an ice thickness probe out of adjustment, or a bin (curtain) switch closed or failed. A harvest can also
  start too early when the high water probe circuit is made while the low one is open.
- **Refrigeration (technician):** non-Manitowoc components, wrong refrigerant charge, a failed head pressure control or
  harvest valve, an expansion valve flooding, a failed fan cycling control, or on water-cooled machines a water regulating
  valve adjusted wrongly or not closing during harvest.

## Thaw cycle and safe mode

Two sequences keep an Indigo NXT making ice while an alert is active:

- **Thaw cycle:** if the curtain doesn't open within the 7-minute harvest, the machine stops the refrigeration and
  circulates, dumps and refills water 18 times to melt the ice off (1 to 1¾ hours, depending on the model), then starts a
  new freeze. To end it early, turn the machine off and on with the keypad; cutting the power instead restarts it in a
  harvest cycle.
- **[Safe mode](https://icepartsdb.com/glossary#safe-mode) (E31):** if the ice thickness probe (E19) or the water level probe (E20) fails, the board runs the machine on
  its model data and recent cycle history for up to 72 hours, then goes to standby and turns off. It leaves safe mode by
  itself if the sensor starts working again.

## Restarting after a shutdown

After a Long Freeze or Long Harvest shutdown, press the green power button on the display, or switch the power off and on.
The board allows this only three times in 24 hours. Find the cause first: the same fault will stop the machine again.

## Questions and answers

### What does E01 mean on a Manitowoc ice machine?

E01 is Long Freeze: the freeze cycle reached 35 minutes in three cycles in a row, and the machine shut down. Manitowoc
says these shutdowns are most often caused by something outside the machine, such as low water pressure, warm water or
a cold room at night; its checklist also includes a dirty water level probe, a clogged distribution tube and a dirty
condenser. Refrigeration faults come last.

### What does E02 mean on a Manitowoc ice machine?

E02 is Long Harvest: the harvest reached 7 minutes in three cycles in a row, and the machine shut down (each long
harvest is followed by a thaw cycle). Manitowoc's checklist includes a dirty evaporator, a stuck curtain or bin switch,
the ice thickness probe adjustment, the dump valve and the harvest valve.

### How do I reset a Manitowoc Indigo NXT ice machine?

Press the green power button that appears on the display after a Long Freeze or Long Harvest shutdown, or switch the
power off and on. It can be restarted this way three times in 24 hours. Clear old alerts in the alert log. Other brands: [how to reset a commercial ice machine](https://icepartsdb.com/guides/how-to-reset-commercial-ice-machine).

### What is Curtain Fault (E12) on a Manitowoc?

The machine has been set to make ice but has read "bin full" for more than 24 hours: the water curtain is open, off, or
its switch isn't working. The bin switch is a magnetic reed switch, so refit the curtain and check that its magnet is in
place.

### What is Safe Mode on a Manitowoc ice machine?

When the ice thickness probe or the water level probe fails, the machine keeps making ice on stored cycle data for up to
72 hours, then turns off. Replace the failed probe within that time.

## Sources

- Manitowoc Ice, [*Indigo NXT Air/Water/Remote Condenser Ice Machines Technician's Handbook*](https://www.manitowocice.com/asset/?id=ebxvra),
  Part Number 000018553 Rev 00 04/26: safety notices (pages 8–9), restart rules (page 62), alert log and alert log detail
  (pages 85–91), E01 and E02 checklists (pages 92–95), reset to factory defaults (page 97), bin switch (page 150),
  high pressure cut-out (page 174).
- Handbooks for other series are on [manitowocice.com](https://www.manitowocice.com) under each model's documents.

## More guides

- [Ice machine not making ice? Causes, checks and the parts that fix them](https://icepartsdb.com/guides/ice-machine-not-making-ice)
- [Hoshizaki ice machine beeping? What 1, 2, 3, 6 and 7 beeps mean (error codes)](https://icepartsdb.com/guides/hoshizaki-ice-machine-error-codes)
- [Scotsman ice machine error codes: Prodigy code display meanings and fixes](https://icepartsdb.com/guides/scotsman-ice-machine-error-codes)
- [Ice-O-Matic ice machine error codes: CIM flashing lights, GEM and MFI service lights](https://icepartsdb.com/guides/ice-o-matic-ice-machine-error-codes)
- [How to reset a commercial ice machine (Hoshizaki, Manitowoc, Scotsman, Ice-O-Matic)](https://icepartsdb.com/guides/how-to-reset-commercial-ice-machine)
- [Ice machine water inlet valve: symptoms, testing and replacement](https://icepartsdb.com/guides/ice-machine-water-inlet-valve)
- [Ice machine water pump: symptoms, testing and replacement](https://icepartsdb.com/guides/ice-machine-water-pump)
- [Ice machine float switch and water level probe: symptoms, testing and replacement](https://icepartsdb.com/guides/ice-machine-float-switch)

## Data sources

- [How we build these pages (methodology)](https://icepartsdb.com/legal/editorial-policy)

Last updated: 2026-11-21

Canonical URL: https://icepartsdb.com/guides/manitowoc-ice-machine-error-codes

Report a correction to this page: https://icepartsdb.com/contact/correction?page=%2Fguides%2Fmanitowoc-ice-machine-error-codes