# Safety disclaimer

Last updated: 2026-11-22

## In short

IcePartsDB provides information only. Disconnect power before servicing. Sealed-system (refrigerant) work must be done by a qualified refrigeration technician (EPA Section 608 certified for refrigerants such as R-404A; trained for flammable refrigerants on R-290 machines), and electrical work by a qualified person. Follow the manufacturer's service manual. You are responsible for any repair you carry out.

A short version of this note appears on pages with diagnostic or repair information.

## Before you work on a machine

- **Disconnect power.** Switch off and lock out the machine at its disconnect or breaker, or unplug it, before you open panels or touch components. Some installations have more than one power supply, for example a remote condenser on its own circuit. Capacitors can hold a charge after the power is off.
- **Shut off the water** before you work on water valves, pumps, filters or lines.
- **Follow the manufacturer's service manual** for your exact model and serial number. Where our information differs from the manual or a manufacturer service bulletin, follow the manufacturer.
- **Use the right tools and protective equipment.** Sheet metal edges and evaporator parts can be sharp, and discharge and hot gas lines can be hot enough to burn.
- **Lift safely.** Ice machines and bins are heavy. Get help or use a lift.

## Refrigerant and the sealed system

Work on the refrigeration circuit must be done by a qualified refrigeration technician. For HFC and other non-exempt refrigerants such as R-404A, R-410A and R-134a, that means a technician certified under Section 608 of the U.S. Clean Air Act (EPA Section 608), or under the equivalent rules where you are. That includes the compressor, condenser, evaporator, expansion device, refrigerant lines and the refrigerant charge. Releasing refrigerant into the air is restricted by law.

Some newer machines use flammable refrigerants such as R-290 (propane). EPA exempts propane in self-contained commercial ice machines from its Section 608 refrigerant rules (40 CFR 82.154), but the machines need extra training, tools and precautions: makers allow only technicians trained for flammable refrigerants to work on them, some require parts from their authorized network, and their power switch may not disconnect all power. Follow the manufacturer's instructions and the labels on the machine.

## Electrical work

Electrical work, such as wiring, control boards, contactors and compressor electrical parts, must be done by a qualified person, following the manufacturer's wiring diagram and local electrical codes. Don't bypass safety controls, such as high-pressure switches or overloads, to keep a machine running.

## Water, plumbing and food safety

Ice is food. Use only cleaning and sanitizing products the manufacturer approves for your machine, and follow its mixing, contact time and rinsing instructions. Never mix ice machine cleaner (an acid) with a chlorine sanitizer: together they give off toxic chlorine gas. Rinse the cleaner out before you sanitize. Discard ice made during cleaning and sanitizing, as the manual instructs. Water supply and drain connections must meet local plumbing and health codes.

## Parts

Parts listed on eBay can be genuine (OEM), aftermarket, used or refurbished. Compatibility shown on IcePartsDB is mostly what sellers claim and is not verified; where we show a maker's parts list, check it against your machine's serial number, because makers change parts during production. A wrong or faulty part can damage the machine or create a hazard, and non-original parts may affect the manufacturer's warranty. Confirm the part number before you install anything.

## No liability

IcePartsDB provides general information about parts and machines. We are not your technician, and we can't see your machine. To the extent the law allows, we are not responsible for injury, damage to property or equipment, voided warranties or other loss resulting from a repair, installation or diagnosis carried out using information from this site. See the [terms of use](https://icepartsdb.com/legal/terms).

If you think something on the site is wrong or unsafe, tell us through the [contact form](https://icepartsdb.com/contact) (choose "correction") and include the page URL.