# Manitowoc UYP0310W-161B + 3 Self-Contained Ice Machine

The Manitowoc UYP0310W-161B + 3 is a water-cooled self-contained ice machine that makes cube ice, rated at 290 lbs of ice per day.

It uses 4.66 kWh and 160 gallons of condenser water per 100 lbs of ice.

Manitowoc's own documents for this model family (installation & use and technician's handbook) are linked below, on Manitowoc's website.

## Specifications

| Fact | Value |
| --- | --- |
| Model number | UYP0310W-161B + 3 |
| Brand | Manitowoc |
| Equipment type | self-contained ice machine |
| Harvest process | batch (cuber) |
| Ice type | cube ice |
| Cooling | water-cooled |
| Harvest rate (lbs/day) | 290 (132 kg) |
| Energy use (kWh/100 lbs ice) | 4.66 |
| Condenser water (gal/100 lbs ice) | 160 |
| ENERGY STAR certified | No |
| DOE basic model | UYP0310W-161B3 |
| eBay listings (ship to US) | 0 |
| Short link | https://icepartsdb.com/p/uyp0310w-161b-3 |

## What does the UYP0310W-161B + 3 cost to run?

Estimate for a machine making ice 42% of the day (DOE's duty cycle, 88 FR 30508 §IV.E.4), from the DOE/ENERGY STAR energy and water figures.

| Item | Estimate |
| --- | --- |
| Ice made | 122 lbs/day |
| Electricity | 2,072 kWh/year ≈ $278/year |
| Water + sewer, if the condenser water runs to the drain (single-pass) | 71,131 gal/year ≈ $1,067/year |
| **Total** | **≈ $1,345/year** |

Formula: lbs/day × 365 ÷ 100 × kWh per 100 lbs × $0.1341/kWh ([EIA 2025 U.S. commercial average](https://www.eia.gov/energyexplained/electricity/prices-and-factors-affecting-prices.php)), plus gallons × $15 per 1,000 gal (assumption: combined water and sewer, as DOE prices it (88 FR 30508 §IV.F.5); local rates vary, so use your bill).

The water line counts the UYP0310W-161B + 3's condenser water (160 gallons per 100 lbs of ice, DOE/ENERGY STAR) as running to the drain (single-pass): about 71,131 gal, $1,067 a year. On a closed loop or cooling tower it doesn't count: about $278 a year in total.

Compare the UYP0310W-161B + 3 with other machines and with ENERGY STAR models of its size, a year and over its life: https://icepartsdb.com/tools/running-cost.md?model1=UYP0310W-161B+%2B+3

## Manitowoc UYP0310W-161B + 3 on eBay

No eBay listings for this exact model right now (eBay checked 2026-11-24 08:45 UTC).

## Parts for the UYP0310W-161B + 3

No eBay seller has named the UYP0310W-161B + 3 in a part listing yet. The surest way to the right part is the number on the old part (a label or a stamped number): look it up at https://icepartsdb.com/search.md?q={part number} (for example https://icepartsdb.com/search.md?q=2A1410-02) or browse Manitowoc parts by type at https://icepartsdb.com/manitowoc.

## Manuals from the maker

NEO UP undercounter cubers, R290 (UP140, UP190, UP240, UP310): Manitowoc's own documents for this model family, on Manitowoc's website.

- [NEO UP Ice Machines, Air- & Water-cooled Models, R290: Installation, Operation and Maintenance Manual](https://www.manitowocice.com/asset/?id=nvxhxz) — Installation & use · No. 040009265 · revised 2025-02 · PDF, 1.7 MB, on manitowocice.com
- [Undercounter (NEO) Ice Machines: Technician's Handbook (all NEO and NEO UP models)](https://www.manitowocice.com/asset/?id=vuczr) — Technician's handbook · No. 000018622 Rev 00 · revised 2025-04 · PDF, 4.3 MB, on manitowocice.com

These are Manitowoc's own documents, linked where Manitowoc publishes them. IcePartsDB doesn't host or copy them and can't vouch for their contents. Check that your model number is listed on the cover: the document for your exact model and serial number is the authority. Links last opened 2026-11-21.

## Age and repair

- [Repair or replace the UYP0310W-161B + 3?](https://icepartsdb.com/tools/repair-or-replace?model=UYP0310W-161B%20%2B%203): Break-even of a repair against a new or used machine, with this model filled in
- [How old is your Manitowoc?](https://icepartsdb.com/tools/serial-number-age?brand=manitowoc): Serial-number age lookup for Manitowoc
- [Reading Manitowoc serial numbers](https://icepartsdb.com/guides/ice-machine-serial-number-age): Where the serial number is and what it says about the build date

## Similar machines

Same type, harvest process and cooling, within 15% of the harvest rate.

| Model | Harvest (lbs/day) | Energy (kWh/100 lbs) | Cooling | Side by side |
| --- | ---: | ---: | --- | --- |
| [Manitowoc UDP0310W-161B + 3](https://icepartsdb.com/manitowoc/machines/udp0310w-161b-3) | 280 | 4.66 | water-cooled | — |
| [Manitowoc UYF0310W-161](https://icepartsdb.com/manitowoc/machines/uyf0310w-161) | 267 | 5.5 | water-cooled | — |
| [Manitowoc UDF0310W-161](https://icepartsdb.com/manitowoc/machines/udf0310w-161) | 252 | 5.6 | water-cooled | — |
| [Scotsman CU3030SWX-1A](https://icepartsdb.com/scotsman/machines/cu3030swx-1a) | 269 | 4.8 | water-cooled | [Compare](https://icepartsdb.com/compare/cu3030swx-1a-vs-uyp0310w-161b-3) |

## Guides

- [Air-, water- or remote-cooled ice machine? Running costs compared](https://icepartsdb.com/guides/air-water-remote-cooled-ice-machines): What air-, water- and remote-cooled ice machines cost to run a year, from DOE and ENERGY STAR data, which ENERGY STAR covers, and when each makes sense.
- [Manitowoc ice machine error codes (Indigo NXT E01 to E31): meanings and fixes](https://icepartsdb.com/guides/manitowoc-ice-machine-error-codes): Every Manitowoc Indigo NXT alert code, E01 Long Freeze to E31 Safe Mode: what triggers it, what Manitowoc says to check, and how to restart.
- [Ice machine not making ice? Causes, checks and the parts that fix them](https://icepartsdb.com/guides/ice-machine-not-making-ice): Why a commercial ice machine makes no ice or too little, in the order a technician checks it, with the parts involved and live eBay prices.
- [How to reset a commercial ice machine (Hoshizaki, Manitowoc, Scotsman, Ice-O-Matic)](https://icepartsdb.com/guides/how-to-reset-commercial-ice-machine): How to reset or restart a Hoshizaki, Manitowoc, Scotsman or Ice-O-Matic ice machine after an alarm, from each maker's manual, and when not to.

## Questions and answers

### How much ice does the Manitowoc UYP0310W-161B + 3 make?

It is rated at 290 lbs of ice per 24 hours in DOE's certification database, measured with DOE's test procedure (90 °F air, 70 °F water for air-cooled units). Real output is lower in hot rooms or with warm inlet water.

### What does it cost to run the Manitowoc UYP0310W-161B + 3?

Making ice 42% of the day, DOE's duty cycle (122 lbs/day), about 2,072 kWh a year: $278 at $0.1341/kWh, plus about $1,067 of water and sewer if the condenser water runs to the drain (single-pass) at $15 per 1,000 gallons.

### Is the Manitowoc UYP0310W-161B + 3 ENERGY STAR certified?

It is not in the current ENERGY STAR list of certified commercial ice machines.

## Sources

- [DOE Compliance Certification Database: Automatic Commercial Ice Makers](https://www.regulations.doe.gov/certification-data/) — 8 fields, retrieved 2026-11-21
- [EIA, Electricity explained: average U.S. commercial price, 2025 (13.41¢/kWh)](https://www.eia.gov/energyexplained/electricity/prices-and-factors-affecting-prices.php) — running-cost estimate
- [DOE, Energy Conservation Standards for Automatic Commercial Ice Makers, proposed rule (88 FR 30508, May 11, 2023), §IV.E.4 "Duty Cycle"](https://www.govinfo.gov/content/pkg/FR-2023-05-11/html/2023-09676.htm) — running-cost estimate: machines make ice 42% of the day (14% for low-capacity machines, rated 50 lb/day or less: §III.B)
- eBay listings (Browse API search results) — 0 active listings matched to UYP0310W-161B + 3
- [How we build these pages (methodology)](https://icepartsdb.com/legal/editorial-policy)

Last updated: 2026-11-21

Canonical URL: https://icepartsdb.com/manitowoc/machines/uyp0310w-161b-3

Short link (cite this page): https://icepartsdb.com/p/uyp0310w-161b-3

Report a correction to this page: https://icepartsdb.com/contact/correction?page=%2Fmanitowoc%2Fmachines%2Fuyp0310w-161b-3