# What does an ice machine cost to run?

**Short answer:** multiply the ice it makes in a year by its DOE / ENERGY STAR rating. Electricity a year = pounds of ice a day × 365 ÷ 100 × kWh per 100 lb of ice × your price per kWh; water is the same with gallons per 100 lb and your water and sewer rate per 1,000 gallons. DOE assumes a machine makes ice 42% of the day (14% for machines rated 50 lb/day or less) and lasts 8.5 years on average. This calculator does it for up to three machines, compares each with a typical ENERGY STAR machine of its size, and shows how long a more efficient machine takes to pay back a higher price.

## Query parameters

Use the same query string as the HTML form, for example https://icepartsdb.com/tools/running-cost.md?model1=IYT0500A-161&model2=IYT0500W-161&icelbs=400&condwater=drain. Up to three machines (1, 2, 3); a machine is its model number, or its figures when it has none we can find. Money in USD without the $ sign; commas only between thousands. A query with any parameter in error gets only the errors.

| Parameter | Meaning |
| --- | --- |
| `model1`, `model2`, `model3` | Model number (DOE / ENERGY STAR rating for capacity, energy and water use; a prefix such as IYT0500A, or a remote head alone, finds the closest model) |
| `price1`, `price2`, `price3` | Price of the machine, for the payback between machines (0 for one you already own; optional) |
| `cap1`, `cap2`, `cap3` | Without a model number: rated capacity, lb per 24 hours |
| `kwh1`, `kwh2`, `kwh3` | Without a model number: energy use, kWh per 100 lb of ice (blank: the median of non-ENERGY STAR DOE models like it) |
| `water1`, `water2`, `water3` | Without a model number: potable water, gallons per 100 lb of ice (optional) |
| `cond1`, `cond2`, `cond3` | Without a model number, water-cooled only: condenser water, gallons per 100 lb (blank: the median of DOE models like it) |
| `cooling1`, `cooling2`, `cooling3` | Without a model number: air = Air-cooled, water = Water-cooled, remote = Remote condenser (including QuietQube) (default air) |
| `style1`, `style2`, `style3` | Without a model number: self_contained = Self-contained (built-in bin, often undercounter), ice_making_head = Ice-making head (sits on a bin) (default ice_making_head) |
| `ice1`, `ice2`, `ice3` | Without a model number: batch = Cube ice (cuber), continuous = Nugget or flake ice (default batch) |
| `icelbs` | Ice you use a day, lb: every machine is priced making this much (not with `duty`) |
| `duty` | Share of the day the machines make ice, % (default DOE's 42%, 14% under 50 lb/day; not with `icelbs`) |
| `years` | Years to count (default DOE's average life, 8.5 years, 7.5 under 100 lb/day) |
| `elec` | Electricity, USD per kWh (default 0.1341, EIA, Electricity explained: average U.S. commercial price, 2025 (13.41¢/kWh)) |
| `waterrate` | Water and sewer, USD per 1,000 gallons (default 15, assumption: combined water and sewer, as DOE prices it (88 FR 30508 §IV.F.5); local rates vary, so use your bill) |
| `condwater` | Water-cooled machines: unsure = Not sure, drain = Runs to the drain (single-pass), loop = Closed loop or cooling tower (default unsure: condenser water shown separately, not in the totals) |

## How the calculator works

1. Ice a day: each machine makes ice 42% of the day, DOE's duty cycle (14% for machines rated 50 lb/day or less), times its rated harvest. Enter your own share of the day, or the ice you use a day to price every machine making the same ice, a like-for-like comparison.
2. Electricity a year = ice a day × 365 ÷ 100 × kWh per 100 lb of ice × your price per kWh. Water a year = ice a day × 365 ÷ 100 × gallons per 100 lb ÷ 1,000 × your water and sewer price per 1,000 gallons. Machine pages use the same formula, but always count a water-cooled machine's condenser water as single-pass (to the drain); here you say where it goes.
3. Figures: each model's DOE / ENERGY STAR rating. Harvest rate and energy use come from DOE's Compliance Certification Database and ENERGY STAR, condenser water from DOE, and potable water from ENERGY STAR, which lists it only for certified models (DOE's database doesn't list it). A remote head is priced on DOE's rating of the head with its remote condenser, with ENERGY STAR's potable water figure for the head. A model number we don't have exactly is matched to the closest model in the data, and the result says so. For a machine you enter by its figures, a blank energy or condenser water figure is filled in from the median of non-ENERGY STAR DOE machines of the same style, ice type and cooling near its size.
4. Condenser water (water-cooled machines) counts only if it runs to the drain (single-pass). On a closed loop or cooling tower it is left out; when you are not sure, it is shown separately and left out of the totals.
5. One basis: the table's cost a year, the ranking and the headline count electricity, condenser water to the drain, and potable water only when it is known for every machine compared.
6. Over its life: the cost a year × DOE's average life, 8.5 years (7.5 years under 100 lb/day), or the years you enter.
7. ENERGY STAR comparison: the median of the ENERGY STAR certified machines of the same style, ice type and cooling rated within ±15% of the machine (widened to ±25% and ±40% to reach 3 machines), making the same ice. Each machine's voltage, cube-size and condenser versions count once, and the machine's own versions are left out; with fewer than 3 the result says so. A water-cooled machine is compared with air-cooled models, because ENERGY STAR certifies only air-cooled ice makers.
8. Machines against each other: ranked by cost a year on that basis. With a price for each, the payback is the price difference ÷ the running-cost saving a year, shown only when the machines make the same ice (enter the ice you use a day) and their condenser water is accounted for.
9. DOE's ratings cover ice making only: standby and ice-storage energy aren't in them (88 FR 30508 §IV.E.1), so a machine that makes ice a small part of the day uses more than its estimate; the result says when that applies.

Guide: [Air-, water- or remote-cooled ice machine? Running costs compared](https://icepartsdb.com/guides/air-water-remote-cooled-ice-machines). Repair or replace calculator: https://icepartsdb.com/tools/repair-or-replace. Sizing calculator: https://icepartsdb.com/tools/ice-machine-sizing.

## Sources

- [DOE Compliance Certification Database: Automatic Commercial Ice Makers](https://www.regulations.doe.gov/certification-data/) — harvest rate, energy use and condenser water of each model, and of the models a typical figure comes from; data last imported 2026-11-21
- [ENERGY STAR Certified Commercial Ice Machines (EPA)](https://data.energystar.gov/Active-Specifications/ENERGY-STAR-Certified-Commercial-Ice-Machines/nak5-fsjf) — which models are ENERGY STAR certified, their energy and potable water use, and the models each machine is compared with; data last imported 2026-11-21
- [U.S. EPA, ENERGY STAR Program Requirements for Automatic Commercial Ice Makers, Version 3.0](https://www.energystar.gov/products/commercial_food_service_equipment/commercial_ice_makers/key_product_criteria) — scope: air-cooled ice-making heads, self-contained and remote condensing units; water-cooled ice makers are excluded (section 2)
- [EIA, Electricity explained: average U.S. commercial price, 2025 (13.41¢/kWh)](https://www.eia.gov/energyexplained/electricity/prices-and-factors-affecting-prices.php) — default electricity price; water and sewer at $15 per 1,000 gallons is an assumption: combined water and sewer, as DOE prices it (88 FR 30508 §IV.F.5); local rates vary, so use your bill
- [DOE, Energy Conservation Standards for Automatic Commercial Ice Makers, proposed rule (88 FR 30508, May 11, 2023)](https://www.govinfo.gov/content/pkg/FR-2023-05-11/html/2023-09676.htm) — lifetime as a distribution with an 8.5-year average, 7.5 years below 100 lb/day (§IV.F, Table IV.9, §IV.F.7); duty cycle 42% for large and 14% for low-capacity machines, rated 50 lb/day or less (§IV.E.4, §III.B)
- [U.S. Department of Energy, test procedure for automatic commercial ice makers (10 CFR 431.134, AHRI Standard 810)](https://www.ecfr.gov/current/title-10/chapter-II/subchapter-D/part-431/subpart-H/section-431.134) — the conditions behind the DOE and ENERGY STAR harvest rates we list
- [EPA, WaterSense at Work, Section 4.2 Commercial Ice Makers (February 2025)](https://www.epa.gov/system/files/documents/2023-05/ws-commercial-watersense-at-work_Section_4.2_Ice_Machines.pdf) — water-cooled ice makers with single-pass cooling use 100–300 gallons of water per 100 lb of ice in total (air-cooled: under 50); a closed loop recirculates the cooling water
- [How we build these pages (methodology)](https://icepartsdb.com/legal/editorial-policy)

Last updated: 2026-11-22

Canonical URL: https://icepartsdb.com/tools/running-cost

Report a correction to this page: https://icepartsdb.com/contact/correction?page=%2Ftools%2Frunning-cost