Repair or replace your ice machine?
Short answer: work out how long the machine must keep running for the repair to pay for itself: the repair cost divided by what a new machine costs per year of its life (DOE puts the average at 8.5 years), less what a new ENERGY STAR machine would save in running costs. If the machine is likely to last longer than that, repair it. This calculator fills in live eBay prices for the part and for used and new machines of your size.
Result
Fill in the repair and your machine, then press Calculate. The recommendation explains each step.
How the recommendation works
- Repair cost = part price + labour hours × your hourly rate + other costs + downtime (days without ice × what you spend on bought ice a day). With a part number we use the median price of its live eBay listings (the figure on the part's page). With a part type we show the range of eBay asking prices for that type; compressors, evaporators, condensers and gear motors vary too much by model, so they need a quote or a part number.
- Replacement prices are eBay asking prices for the head or machine only, not installed: one vote per seller (the median of each seller's listings, at least 3 sellers) for machines of the same style (self-contained, head or remote) and ice type rated within ±15% of your capacity, widened to ±25% and ±40% if needed. Bundles (with a bin, dispenser or other items), auctions and "for parts" listings are left out; open-box, scratch-and-dent and floor models count as used. A used figure that asks 90% or more of the new one is left out. Your own figures replace ours.
- Break-even: a new machine costs its price (plus installation) spread over DOE's 8.5-year average life (7.5 years under 100 lb/day). Keeping the old one also costs its extra running cost against a typical ENERGY STAR model of the same size. The repair pays for itself if the machine runs longer than repair cost ÷ (new machine per year − extra running cost per year).
- We compare that with the years the machine has left: the rest of the 8.5-year average, and at least 3 years for a machine that is still running at or past it, because DOE treats lifetime as a spread around the average. Replacing looks better only when the break-even is longer than that, or when the repair costs as much as a new machine; within 75–100% of it we call it too close.
- Running cost uses DOE's duty cycle (the machine makes ice 42% of the day, 14% for machines rated 50 lb/day or less), EIA's U.S. average commercial electricity price and a water and sewer rate you can change. A water-cooled machine is compared with air-cooled ENERGY STAR models; its condenser water (DOE data) counts only if you say it runs to the drain (single-pass), not for a closed loop or cooling tower, and when you are not sure we show it separately.
- Consumer Reports' 50% rule for home appliances is shown for reference only; it is not part of the recommendation.
Related
- Find a machine's age from its serial number
- Ice machine sizing calculator (if you replace, check the size first)
- Refrigerant changes and the EPA rules
- Hoshizaki parts by type, with live prices
- Manitowoc parts by type, with live prices
- Scotsman parts by type, with live prices
- Ice-O-Matic parts by type, with live prices
- Follett parts by type, with live prices
- All tools
Sources
- eBay listings (Browse API search results) — part prices and asking prices of used and new machines matched to DOE / ENERGY STAR models, refreshed several times a day
- DOE Compliance Certification Database: Automatic Commercial Ice Makers — harvest rate, energy and condenser water use of your model and of similar models
- ENERGY STAR Certified Commercial Ice Machines (EPA) — which models are ENERGY STAR certified
- EIA, Electricity explained: average U.S. commercial price, 2025 (13.41¢/kWh) — electricity price for the running-cost comparison; water and sewer at $15 per 1,000 gallons is an assumption: combined water and sewer, as DOE prices it (88 FR 30508 §IV.F.5); local rates vary, so use your bill
- DOE, Energy Conservation Standards for Automatic Commercial Ice Makers, proposed rule (88 FR 30508, May 11, 2023) — lifetime as a distribution with an 8.5-year average, 7.5 years below 100 lb/day (§IV.F, Table IV.9, §IV.F.7); duty cycle 42% for large and 14% for low-capacity machines, rated 50 lb/day or less (§IV.E.4, §III.B)
- Consumer Reports, "Consumer Reports Offers Insights on When to Repair and When to Replace" (press release about home appliances, January 9, 2014), copy hosted by PR Newswire — rule of thumb for home products: "don't spend more than 50 percent of the cost of a new product on repairing an old one"; shown for reference only
- EPA, WaterSense at Work, Section 4.2 Commercial Ice Makers (February 2025) — water-cooled ice makers with single-pass cooling use 100–300 gallons of water per 100 lb of ice in total (air-cooled: under 50); a closed loop recirculates the cooling water
- How we build these pages (methodology)