A

Aftermarket part

A replacement part made by someone other than the machine's manufacturer, sold as "compatible with", "replacement for" or "fits" an OEM part number. It usually costs less than the OEM part; fit and quality vary by seller, so compare it with the old part and check what it means for any warranty.

Also called: compatible part, replacement part, generic part

See also: OEM, Supersession

Guide: OEM vs aftermarket ice machine parts: price gap and when each makes sense

AHRI rating conditions (90 °F air / 70 °F water)

The standard test conditions behind the harvest rate, energy and water figures in DOE and ENERGY STAR data: 90 °F (32 °C) air around the machine and 70 °F (21 °C) incoming water, set by AHRI Standard 810 and the DOE test procedure. Brochures often also quote output at 70 °F air and 50 °F water, which gives a bigger number, so compare machines at 90/70.

Also called: 90/70 rating, AHRI 810, standard rating conditions

See also: Harvest rate, kWh per 100 lb of ice, Ambient temperature, DOE efficiency standards, Model number

Air filter

A washable mesh filter in front of the air-cooled condenser on many cube machines that catches dust and grease before they clog the coil. A blocked filter raises head pressure, cuts production and can trip the high pressure cut-out, so clean it as often as the manual says.

Also called: condenser filter

See also: Air-cooled condenser, Head pressure, High pressure cut-out

Guide: How to clean and sanitize a commercial ice machine (and how often)

Air gap

An open vertical space between the end of a drain line and the floor sink or drain it empties into, so waste water can never be drawn back into the machine or the bin. Food and plumbing codes generally require ice machine and bin drains to discharge through an air gap rather than connect directly to the sewer; the local code has the details.

See also: Bin, Condenser water

Air-cooled condenser

A condenser cooled by a fan pulling room air through a finned coil: the most common type, and the cheapest to install. It puts the machine's heat and fan noise into the room, needs the clearances the installation manual gives, and makes less ice in a hot room or with a dirty coil.

Also called: air-cooled ice machine

See also: Condenser, Water-cooled condenser, Remote condenser, Condenser fan motor, Air filter, Fan cycle control

Guide: Air-, water- or remote-cooled ice machine? Running costs compared

Browse: Hoshizaki, Manitowoc, Scotsman, Ice-O-Matic and Follett condensers; Hoshizaki, Manitowoc, Scotsman, Ice-O-Matic and Follett condenser fan motors

Ambient temperature

The temperature of the air around the machine, or around a remote condenser outdoors. The hotter it is, the less ice the machine makes (output is rated at 90 °F), and each maker's installation manual gives the lowest and highest temperatures the machine may run in.

Also called: room temperature, ambient

See also: AHRI rating conditions (90 °F air / 70 °F water), Harvest rate, Air-cooled condenser, Remote condenser

Anti-slush

A control feature that stops the water pump for a few seconds early in the freeze, when the water is close to freezing, so it doesn't turn to slush. Scotsman Prodigy cubers stop the pump for 30 seconds when the water reaches a set temperature; Hoshizaki cubers with the feature switched on stop it for 10 seconds when the thermistor reads 36 °F.

See also: Freeze cycle, Water pump, Thermistor

Guide: Hoshizaki ice machine beeping? What 1, 2, 3, 6 and 7 beeps mean (error codes)

AuCS

Manitowoc's Automatic Cleaning System: an accessory that monitors the ice-making cycles and starts a cleaning by itself. On Indigo NXT machines the version is called iAuCS: its cleaning frequency is set in the touchscreen menu, the Clean button doesn't start it, and alert E28 means the control can't find the iAuCS board. It doesn't replace the full cleaning and sanitizing Manitowoc calls for at least every six months.

Also called: iAuCS, Automatic Cleaning System

See also: Descaling, Sanitizing, Indigo NXT, Error code

Guide: Manitowoc ice machine error codes (Indigo NXT E01 to E31): meanings and fixes

Auger

The screw that turns inside the freezing cylinder of a flake or nugget machine, scraping ice off the cold wall and pushing it up and out through the extruding head. Worn auger bearings or scale in the cylinder show up as squealing, grinding and a straining gear motor.

See also: Gear motor, Extruding head, Evaporator, Continuous ice machine, Flake ice, Nugget ice

Browse: Hoshizaki, Manitowoc, Scotsman, Ice-O-Matic and Follett augers

Back to the letter index

B

Batch ice machine

A machine that makes ice in alternating freeze and harvest cycles, a sheet of cubes at a time; every cube machine works this way. DOE defines a batch type ice maker as one "having alternate freezing and harvesting periods".

Also called: batch type, cuber, cube machine

See also: Continuous ice machine, Freeze cycle, Harvest, Cube ice

Bin

The insulated box that stores the ice, either under an ice-making head or built into a self-contained machine. Bins are sold by storage capacity in pounds and must match the head's width, or take an adapter; size the head for the ice you use in a day and the bin for the amount you need on hand at the busiest time.

Also called: ice bin, storage bin, ice storage bin

See also: Ice-making head, Bin control, Self-contained ice machine, Dispenser

Browse: Hoshizaki, Manitowoc and Ice-O-Matic ice bins

Bin control

The switch, thermostat or sensor that stops ice production when the bin is full and starts it again as ice is used. Depending on the machine it is a bin thermostat whose sensing bulb is chilled by ice touching it, a lever or paddle the ice pushes, the curtain switch on curtain-type cubers, or an electronic (for example infrared) ice level sensor.

Also called: bin thermostat, bin switch, ice level control, bin full sensor

See also: Bin, Water curtain, Thermistor

Browse: Hoshizaki, Manitowoc, Scotsman and Ice-O-Matic bin controls

Back to the letter index

C

Capacitor

A start capacitor gives a single-phase compressor or motor extra torque for the first moment of a start and is then switched out by the start relay; a run capacitor stays in the circuit to help it run efficiently. A swollen, leaking or weak capacitor can leave the compressor humming and tripping its overload instead of starting, and any capacitor can hold a dangerous charge after the power is off, so a technician discharges it before handling it.

Also called: start capacitor, run capacitor

See also: Start relay, Compressor, Overload, Contactor

Browse: Hoshizaki, Manitowoc, Scotsman, Ice-O-Matic and Follett relays & capacitors

Compressor

The pump at the heart of the refrigeration system: it draws in low-pressure refrigerant vapor from the evaporator and compresses it into hot, high-pressure gas for the condenser. Replacing one is work for a refrigeration technician (EPA Section 608 certified on HFC machines, trained for flammable refrigerants on R-290 machines), and its cost is often weighed against a new machine (see the repair or replace calculator).

See also: Condenser, Evaporator, Sealed system, EPA Section 608, R-290, Contactor, Start relay

Browse: Hoshizaki, Manitowoc, Scotsman, Ice-O-Matic and Follett compressors

Condenser

The heat exchanger where hot, high-pressure refrigerant from the compressor gives up its heat and condenses into a liquid. It is cooled by room air (air-cooled) or by water (water-cooled), or installed away from the machine, usually outdoors (remote); the choice decides where the heat goes and what the machine costs to run.

See also: Air-cooled condenser, Water-cooled condenser, Remote condenser, Condenser fan motor, Head pressure

Guide: Air-, water- or remote-cooled ice machine? Running costs compared

Browse: Hoshizaki, Manitowoc, Scotsman, Ice-O-Matic and Follett condensers

Condenser fan motor

The motor and blade that move air through an air-cooled or remote condenser. If it stops, head pressure climbs quickly and the high pressure cut-out or the controller shuts the machine down.

Also called: fan motor, condenser fan

See also: Air-cooled condenser, Remote condenser, Head pressure, High pressure cut-out, Fan cycle control

Browse: Hoshizaki, Manitowoc, Scotsman, Ice-O-Matic and Follett condenser fan motors

Condenser water

Water that runs through a water-cooled condenser to carry away the machine's heat; it never touches the ice and, on a once-through system, goes straight down the drain. DOE rates condenser water use in gallons per 100 lb of ice: typically 100 to 160 gallons in DOE data, about ten times the 12 gallons or so that become the ice.

Also called: condenser water use

See also: Water-cooled condenser, Potable water, Water regulating valve

Guide: Air-, water- or remote-cooled ice machine? Running costs compared

Condensing unit

The compressor and condenser, with their fan, receiver and controls, packaged as one unit. In a remote low-side system such as Manitowoc's QuietQube it sits outdoors or on the roof and connects to the ice machine head by a refrigerant line set.

Also called: CVD unit

See also: Remote low side, QuietQube, Line set, Compressor, Remote condensing

Contactor

A heavy-duty relay that the controller uses to switch the compressor (and often the condenser fan) on and off; on ice machines its coil usually runs at line voltage. Burned or welded contacts can leave the compressor unable to start or unable to stop.

See also: Compressor, Control board, Start relay

Browse: Hoshizaki, Manitowoc, Scotsman, Ice-O-Matic and Follett relays & capacitors

Continuous ice machine

A machine that freezes and harvests at the same time, with no separate cycles: flake and nugget machines, in which an auger scrapes ice continuously off a refrigerated cylinder. DOE defines a continuous type ice maker as one "that continually freezes and harvests ice at the same time".

Also called: continuous type, flaker

See also: Batch ice machine, Auger, Gear motor, Flake ice, Nugget ice

Control board

The electronic controller that runs the freeze and harvest sequence: it reads the sensors (probes, thermistors, float or level sensors, bin control), switches the valves, pump and compressor, and shows error codes or beeps when something is wrong. Many suspected board failures turn out to be a sensor, switch or power supply problem, so check those first.

Also called: PC board, control module, controller, main board

See also: Error code, Thermistor, Ice thickness probe, Transformer

Guide: Ice machine control board: signs of failure, what to check first, and replacement

Browse: Hoshizaki, Manitowoc, Scotsman, Ice-O-Matic and Follett control boards

Crescent cube

Hoshizaki's cube, flat on one side and rounded on the other, formed on a double-sided evaporator in its KM crescent cubers. Hoshizaki describes it as clear, hard ice, and sells crescent cubers built to sit on drink dispensers.

Also called: crescent ice

See also: Cube ice, KM series, Half dice cube, Evaporator

Browse: Hoshizaki ice machines

Cube ice

Hard, clear cubes made in batches, usually on a vertical evaporator: the all-round ice for drinks, and the type most restaurants and bars use. Each maker has its own shapes and names (dice, half dice and regular at Manitowoc, medium and small cubes at Scotsman, crescent at Hoshizaki, and gourmet cubes), and the size matters for drink dispensers and how a glass fills.

Also called: cubes, cuber ice

See also: Dice cube, Half dice cube, Regular cube, Crescent cube, Gourmet ice, Batch ice machine

Browse: Hoshizaki, Manitowoc, Scotsman, Ice-O-Matic and Follett ice machines

Cubelet

Hoshizaki's name for its chewable nugget ice, made by its continuous auger machines and also sold in a softer "Soft Cubelet" version. It is the same family of ice that other makers call nugget ice.

Also called: cubelet ice, soft cubelet

See also: Nugget ice, Flake ice, Continuous ice machine

Back to the letter index

D

Data plate

The label on the machine, usually on the back panel or behind a front panel, with the model and serial numbers, the electrical supply (volts, phase, hertz), the minimum circuit ampacity and maximum fuse or breaker size, and the refrigerant type and charge. Read it before ordering parts, wiring a circuit or calling for service.

Also called: serial plate, nameplate, rating label

See also: Model number, Serial number

Guide: Ice machine serial number lookup: how old is my Hoshizaki, Manitowoc, Scotsman or Ice-O-Matic?

Descaling

Dissolving scale out of the evaporator and water system with an acid-based, food-grade ice machine cleaner, as the first step of a cleaning. It is a different job from sanitizing: the cleaner removes minerals, the sanitizer kills microbes, and makers' procedures do both, cleaner first. Rinse the cleaner out before sanitizing and never mix the two: acid cleaner and chlorine sanitizer together give off toxic chlorine gas.

Also called: de-scaling, deliming, scale removal, ice machine cleaner

See also: Scale, Sanitizing, Nickel-safe cleaner, Water hardness, AuCS

Guide: How to clean and sanitize a commercial ice machine (and how often)

Dice cube

Manitowoc's full-size cube, 7/8 × 7/8 × 7/8 in (2.2 cm on each side), about 48 cubes to the pound; Scotsman's medium cube is the same size. An all-round cube for drinks, bins and bagged ice.

Also called: full dice, full cube, medium cube

See also: Half dice cube, Regular cube, Cube ice

Dispenser

A machine that stores ice and delivers it into a cup or bucket at the push of a lever or button, so nobody scoops from an open bin. Some make their own ice (countertop ice and water dispensers, usually with nugget ice); others are fed by an ice-making head mounted on top.

Also called: ice dispenser, ice and water dispenser, beverage dispenser

See also: Bin, Ice-making head, Nugget ice, Crescent cube

Browse: Hoshizaki, Manitowoc, Scotsman and Follett dispenser parts

Distribution tube

The perforated tube or trough across the top of a cube machine's evaporator that spreads the water from the pump evenly over the freezing surface. Scale in its holes leaves part of the plate with thin or missing cubes; it lifts out for cleaning.

Also called: water distributor, distributor tube, spray bar

See also: Water pump, Evaporator, Scale

Guide: Ice machine water pump: symptoms, testing and replacement

DOE Compliance Certification Database

The U.S. Department of Energy's public list of the models manufacturers have certified as meeting federal efficiency standards, with each model's rated harvest rate, energy use and water use. IcePartsDB's machine specifications come from it and from the ENERGY STAR list (how we build these pages).

Also called: CCD, DOE database

See also: DOE efficiency standards, ENERGY STAR, Harvest rate

DOE efficiency standards

Federal minimum efficiency rules for automatic commercial ice makers: a maximum energy use (and, for water-cooled models, condenser water use) for each type and size, measured with the DOE test procedure. The current levels apply to machines made since January 28, 2018 that produce 50 to 4,000 lb of ice a day. In May 2025 DOE proposed returning the water-use limits to the original statutory levels; as of November 2026 DOE's page still lists that as a proposal.

Also called: DOE standards, federal efficiency standards

See also: DOE Compliance Certification Database, ENERGY STAR, AHRI rating conditions (90 °F air / 70 °F water), kWh per 100 lb of ice, Condenser water

Door gasket

The rubber or foam strip around a bin or dispenser door that closes the gap when the door shuts. A torn, flattened or hardened gasket lets warm, humid air in, so stored ice melts faster and water or frost collects around the door; it is replaced when it no longer seals evenly all the way round.

Also called: door seal, bin door gasket

See also: Bin, Door hinge, Dispenser

Browse: Hoshizaki, Manitowoc, Scotsman, Ice-O-Matic and Follett gaskets & seals

Door hinge

The hinge, pivot or track a bin or dispenser door moves on; the latches and catches that hold the door open or shut are sold with them. A worn hinge lets the door sag so its gasket no longer seals, and a broken catch leaves a lift door falling shut.

Also called: door pivot

See also: Door gasket, Bin

Browse: Hoshizaki, Manitowoc, Scotsman, Ice-O-Matic and Follett doors & hinges

Drain line

The hose or tubing that carries melt water from the bin and purge water from the machine to a floor drain. It needs a steady downward slope and, at the drain, an air gap, which plumbing codes require so waste water can't be drawn back; a kinked, clogged or sagging drain line backs water up into the bin or the machine's base.

Also called: drain hose, drain tube

See also: Bin, Sump

Browse: Hoshizaki, Manitowoc, Scotsman, Ice-O-Matic and Follett hoses & tubing

Dump valve

A solenoid valve that drains the water left in the trough at harvest, flushing away the minerals that concentrate as water freezes so that less scale forms. Scotsman calls it the purge valve and lets you set how much water is purged to suit the local water; Hoshizaki cubers drain their water tank in a separate pump-out step.

Also called: purge valve, drain valve, water dump valve

See also: Pump-out, Scale, Sump, Water inlet valve, Potable water

Guide: Ice machine water inlet valve: symptoms, testing and replacement

Browse: Hoshizaki, Manitowoc, Scotsman, Ice-O-Matic and Follett water inlet valves

Back to the letter index

E

Elevation Series

Ice-O-Matic's name for its CIM modular cubers. In a CIM model number the letters after the capacity are the cube size (H half, F full, G grande) and the condenser (A air, W water, R remote, T top discharge), and the last two digits are the refrigerant: 90 for R-290, 49 for R-449A, none for the older R-404A models. So CIM0530HA90 and CIM0530HA are different machines.

Also called: CIM, CIM cuber, Ice-O-Matic Elevation

See also: Model number, R-290, R-404A, Cube ice

Guide: Ice-O-Matic ice machine error codes: CIM flashing lights, GEM and MFI service lights

ENERGY STAR

The U.S. EPA's efficiency label. For commercial ice makers it covers air-cooled cube, flake and nugget machines (heads, self-contained and remote condensing, but not water-cooled machines or ice and water dispensers); certified cube machines are about 10% more energy efficient and 20% more water efficient than standard models, and continuous ones about 16% more energy efficient.

Also called: ENERGY STAR certified

See also: DOE efficiency standards, DOE Compliance Certification Database, kWh per 100 lb of ice, Air-cooled condenser

EPA Section 608

Clean Air Act rules (40 CFR Part 82, Subpart F) that require technicians who open refrigeration systems charged with ozone-depleting or HFC refrigerants, such as R-404A or R-410A, to be certified and to recover the refrigerant instead of venting it. Type I covers small appliances factory-sealed with 5 lb or less of refrigerant, which include under-the-counter ice makers; larger ice machines generally need Type II (high-pressure), and Universal covers every type. R-290 in self-contained ice machines is exempt, but makers allow only technicians trained for flammable refrigerants to work on it.

Also called: Section 608 certification, EPA 608

See also: Sealed system, Compressor, R-404A, R-290

Error code

A number, letter or beep pattern the control board gives when a check fails, for example a freeze or harvest that took too long or a sensor reading out of range. Codes differ by maker and control generation, so look yours up before buying parts.

Also called: alarm code, alert code, fault code, safety limit

See also: Control board, Indigo NXT, Prodigy, KM series, Safe mode

Guides: Hoshizaki ice machine beeping? What 1, 2, 3, 6 and 7 beeps mean (error codes), Manitowoc ice machine error codes (Indigo NXT E01 to E31): meanings and fixes, Scotsman ice machine error codes: Prodigy code display meanings and fixes

Evaporator

The cold surface the water freezes on. In a cube machine it is usually a vertical plate or grid of cells (nickel-plated copper on many machines) chilled by refrigerant tubing on the back; in flake and nugget machines it is the freezing cylinder around the auger, and replacing either is sealed-system work.

Also called: evaporator plate, freezing cylinder

See also: Harvest, Freeze cycle, Auger, Hot gas valve, Nickel-safe cleaner

Browse: Hoshizaki, Manitowoc, Scotsman, Ice-O-Matic and Follett evaporators

Expansion valve (TXV)

The thermostatic expansion valve meters liquid refrigerant into the evaporator, opening and closing with a sensing bulb clamped to the evaporator outlet so the evaporator stays fed without sending liquid back to the compressor. One that sticks or underfeeds gives long freeze cycles and uneven ice; some small machines use a fixed capillary tube instead.

Also called: TXV, TEV, thermostatic expansion valve, metering device

See also: Evaporator, Liquid line valve, Freeze cycle, Sealed system

Extruding head

The fitting at the top of a flake or nugget machine's freezing cylinder that the auger pushes the ice through; on nugget machines it compresses the flakes into nuggets, and on many machines it also holds the top auger bearing. On Scotsman machines the equivalent part is called the breaker.

Also called: breaker, ice breaker

See also: Auger, Gear motor, Nugget ice, Flake ice

Browse: Hoshizaki, Manitowoc, Scotsman, Ice-O-Matic and Follett augers

Back to the letter index

F

Fan cycle control

A pressure switch that turns an air-cooled condenser's fan on when the discharge (head) pressure rises and off when it falls, so the fan cycles during the freeze to hold the pressure steady. On Indigo NXT machines it closes at about 250 psig and opens at about 200 psig with R-404A (335/275 with R-410A, 200/150 with R-290); one stuck closed keeps the pressure too low, and alert E15 means the liquid line stayed below 60 °F for over a minute in the freeze.

Also called: fan cycle pressure control, fan pressure control, fan cycling switch

See also: Condenser fan motor, Head pressure, Air-cooled condenser, High pressure cut-out

Guide: Ice machine condenser fan motor: symptoms, testing and replacement

Filter-drier

A small canister in the liquid line that traps moisture, acid and debris in the refrigerant. Technicians replace it whenever the sealed system is opened, for example to change a compressor or a valve.

Also called: drier, liquid line drier

See also: Sealed system, Liquid line valve, Compressor

Flake ice

Soft, slightly wet chips of ice made continuously by an auger scraping a refrigerated cylinder. It molds around food and chills it quickly, so it is used for seafood and produce displays, salad bars and in healthcare.

Also called: flaked ice, flaker ice

See also: Continuous ice machine, Auger, Nugget ice, Gear motor

Browse: Hoshizaki, Manitowoc, Scotsman, Ice-O-Matic and Follett ice machines

Float switch

A float on a stem in the water trough with a magnet that works a reed switch as the level rises and falls, telling the control board when the trough is full. On many Hoshizaki cubers the falling float also tells the board the water has frozen onto the plate and harvest can start; scale that sticks the float is the usual failure.

Also called: float, water level switch

See also: Water level probe, Sump, Water inlet valve, Freeze cycle

Guide: Ice machine float switch and water level probe: symptoms, testing and replacement

Browse: Hoshizaki, Manitowoc, Scotsman, Ice-O-Matic and Follett float switches

Freeze cycle

The part of a batch machine's cycle when the refrigeration system chills the evaporator and the water pump runs water over it until the cubes reach full size. A probe, float, thermistor or timer then ends it and starts the harvest; it takes longer in a hot room or with warm water, and a freeze that runs too long is one of the most common error codes.

Also called: freeze, freezing cycle

See also: Harvest, Batch ice machine, Ice thickness probe, Float switch, Anti-slush, Error code

Guide: Ice machine not making ice? Causes, checks and the parts that fix them

Back to the letter index

G

Gear motor

The electric motor and gearbox that turn the auger in a flake or nugget machine. Grinding noise, oil leaks or tripping on overload usually point to worn gears or bearings, or to an auger straining against scale in the cylinder.

Also called: gearmotor, auger motor, drive motor

See also: Auger, Extruding head, Continuous ice machine

Browse: Hoshizaki, Manitowoc, Scotsman and Follett gear motors

Global warming potential (GWP)

How much a refrigerant warms the climate compared with the same mass of carbon dioxide (GWP 1) over 100 years: R-404A is about 3,900 and propane (R-290) is 3. Under the AIM Act, EPA limits new self-contained ice machines (cubers up to 1,000 lb a day, flake and nugget machines up to 1,200 lb) to a GWP of 150 or less from January 1, 2026, and bans R-404A and other listed HFCs in larger self-contained machines and in newly installed remote machines from January 1, 2027. EPA's May 2026 revision of these rules left the ice machine dates unchanged.

Also called: GWP, low-GWP refrigerant

See also: R-404A, R-290, EPA Section 608

Gourmet ice

Large, crystal-clear, slow-melting cubes for cocktails and upscale bars, often made by small undercounter machines: Scotsman's gourmet cubers, Manitowoc's octagonal gourmet cube (about 1-3/8 in across) and Hoshizaki's top hat cube.

Also called: gourmet cube, top hat cube

See also: Cube ice, Self-contained ice machine

Back to the letter index

H

Half dice cube

Manitowoc's half-size cube, 3/8 × 1-1/8 × 7/8 in, about 96 cubes to the pound; Scotsman's small cube (3/8 × 7/8 × 7/8 in) is similar. The thin cubes pack a glass tightly and displace more drink, so they suit soft drink dispensers.

Also called: half dice, half cube, small cube

See also: Dice cube, Regular cube, Cube ice, Crescent cube

Harvest

The part of a batch machine's cycle that releases the finished ice: the hot gas valve sends hot refrigerant gas through the evaporator so the ice loosens and drops into the bin (QuietQube units use refrigerant vapor from the receiver instead), often helped by a harvest assist. The board ends the harvest when it senses the ice has fallen (curtain switch) or the evaporator has warmed (thermistor), or when a timer runs out, and starts the next freeze.

Also called: harvest cycle, defrost

See also: Freeze cycle, Hot gas valve, Harvest assist, Water curtain, Thermistor, Ice bridge, Thaw cycle

Guide: Ice thickness probe and thermistor: how ice machines decide when to harvest

Browse: Hoshizaki, Manitowoc, Scotsman and Ice-O-Matic hot gas valves

Harvest assist

Anything besides the hot gas that helps the ice let go of the evaporator at harvest. Manitowoc models that have one use an air pump that breaks the vacuum between the ice sheet and the evaporator; Scotsman Prodigy cubers push the slab off with a solenoid-driven pin that springs back; Hoshizaki cubers let water flow over the evaporator during harvest and can run the water pump in its last seconds (the "harvest pump time").

Also called: harvest assist air pump, harvest assist solenoid, harvest assist probe, harvest pump time

See also: Harvest, Hot gas valve, Water inlet valve, Evaporator

Guide: Ice machine water inlet valve: symptoms, testing and replacement

Harvest pressure regulating valve (HPR)

On Manitowoc remote-condenser ice machines, a solenoid valve and a pressure-regulating valve that open only during harvest, letting refrigerant gas from the top of the receiver join the harvest. The regulating valve raises the suction pressure enough to keep the harvest warm without the refrigerant condensing in the evaporator; Indigo NXT remote models use either an HPR valve or a condenser bypass valve (CBV).

Also called: HPR valve, HPRV, HPR solenoid, harvest pressure regulator

See also: Harvest, Receiver, Remote condenser, Hot gas valve

Harvest rate

How much ice a machine makes in 24 hours, in pounds, at the AHRI rating conditions of 90 °F air and 70 °F water: the capacity figure in DOE and ENERGY STAR data. Real output is lower in a hotter room or with warmer water, so size a machine with some headroom over your busiest day (the sizing calculator does the sums).

Also called: ice production, capacity, lbs/day, lb/24 h

See also: AHRI rating conditions (90 °F air / 70 °F water), Ambient temperature, kWh per 100 lb of ice, DOE Compliance Certification Database

Head pressure

The refrigerant pressure on the high side of the system, from the compressor through the condenser to the expansion valve. It rises when the condenser can't shed heat (dirty coil or filter, failed fan, hot room, no condenser water), which trips the high pressure cut-out; too low a head pressure, as with a remote condenser in winter, starves the evaporator.

Also called: discharge pressure, high-side pressure, condensing pressure

See also: High pressure cut-out, Head pressure control valve, Condenser, Water regulating valve, Fan cycle control

Head pressure control valve

A valve on remote-condenser systems that holds a minimum head pressure in cold weather by backing liquid refrigerant up in the condenser and sending hot gas straight to the receiver. A faulty one causes freeze and harvest problems that come and go with the weather; Hoshizaki calls it the C.P.R. valve.

Also called: headmaster, head pressure control, C.P.R. valve

See also: Remote condenser, Receiver, Head pressure

High pressure cut-out

A pressure switch on the high side that cuts power to the compressor if head pressure gets dangerously high, for example when the condenser is clogged, its fan fails or the condenser water stops. Some reset themselves and others have a reset button; repeated trips mean the cause needs fixing, not the switch.

Also called: high pressure switch, high pressure cutout, HPCO

See also: Head pressure, Condenser fan motor, Air filter, Water-cooled condenser

Hot gas valve

The solenoid valve that, at harvest, opens a bypass from the compressor discharge to the evaporator inlet, so hot refrigerant gas warms the plate and releases the ice. One that leaks through during the freeze gives long freeze cycles and small cubes; one that doesn't open gives long harvests.

Also called: harvest valve, hot gas solenoid

See also: Harvest, Harvest assist, Evaporator, Freeze cycle

Browse: Hoshizaki, Manitowoc, Scotsman and Ice-O-Matic hot gas valves

Back to the letter index

I

Ice bridge

The thin layer of ice joining the cubes in one harvested sheet on Manitowoc, Scotsman and similar cubers; its thickness shows whether the ice thickness probe is set right. Manitowoc sets it at about 1/8 in (3 mm) and Scotsman at 1/8 to 3/16 in. Too thick, and the cubes stay joined and can freeze to the evaporator frame; too thin, and the cubes come out small and the sheet may not swing the curtain open. Either can end in a long-harvest fault.

Also called: bridge thickness

See also: Ice thickness probe, Harvest, Cube ice, Water curtain

Guide: Ice thickness probe and thermistor: how ice machines decide when to harvest

Ice thickness probe

A probe held a set distance in front of a cube machine's evaporator that tells the control board the ice is thick enough to harvest. On Scotsman Prodigy and older Manitowoc machines the water flowing over the growing ice touches it for a few seconds and the board senses the water by conductivity; current Manitowoc Indigo NXT probes use a small microphone that picks up the change as the ice builds. The gap sets the cube size (Manitowoc starts at 9/32 in, Scotsman at 7/32 in), and dirt or scale on the probe changes the bridge thickness.

Also called: ice thickness sensor, harvest probe

See also: Ice bridge, Harvest, Freeze cycle, Thermistor, Safe mode

Guide: Ice thickness probe and thermistor: how ice machines decide when to harvest

Browse: Hoshizaki, Manitowoc, Scotsman, Ice-O-Matic and Follett thermistors & sensors

Ice-making head

An ice machine without its own storage: it sits on a separate bin or dispenser bought to match. DOE defines ice-making heads as automatic commercial ice makers that "do not contain integral storage bins"; they typically make from a few hundred to a few thousand pounds of ice a day.

Also called: modular ice machine, modular cuber, IMH

See also: Bin, Dispenser, Self-contained ice machine, Remote condensing

Browse: Hoshizaki, Manitowoc, Scotsman, Ice-O-Matic and Follett ice machines

Indigo NXT

Manitowoc's Indigo NXT series of cube machines, whose controller reports alerts as codes E01 to E31. In the model number the second letter is the cube (Y half dice, D dice, R regular) and the third the refrigerant (F R-404A, T R-410A, P R-290), as in IYT, IDF or IRP, and the digits give the output at 70 °F air and 50 °F water. Parts and service steps differ from older Manitowoc series, so check the series before ordering.

See also: Error code, Control board, QuietQube, Model number, LuminIce, AuCS

Guide: Manitowoc ice machine error codes (Indigo NXT E01 to E31): meanings and fixes

Browse: Manitowoc ice machines

Back to the letter index

K

KM series

Hoshizaki's line of crescent cube machines, with model numbers starting KM. Their control boards signal faults with a set number of beeps.

Also called: Hoshizaki crescent cuber

See also: Crescent cube, Error code, Control board, Thermistor

Guide: Hoshizaki ice machine beeping? What 1, 2, 3, 6 and 7 beeps mean (error codes)

Browse: Hoshizaki ice machines

Koolaire

An ice machine brand from Manitowoc: Manitowoc's model nomenclature lists Koolaire (K) as one of its series, and Koolaire model numbers follow the same pattern, for example KYT1700A for a half dice, R-410A, air-cooled machine.

Also called: Kool-Aire

See also: Model number, Indigo NXT

Guide: How to find your ice machine's model number and the right part number

kWh per 100 lb of ice

The energy rating of an ice machine: the kilowatt-hours of electricity it uses to make 100 lb of ice at the AHRI rating conditions. Lower is better; multiply by the hundreds of pounds you make in a year and your electricity price to estimate the running cost (water-cooled machines also use condenser water, rated in gallons per 100 lb).

Also called: energy use, kWh/100 lb, kWh/100 lbs

See also: Harvest rate, AHRI rating conditions (90 °F air / 70 °F water), ENERGY STAR, DOE efficiency standards, Condenser water

Guide: Air-, water- or remote-cooled ice machine? Running costs compared

Back to the letter index

L

Line set

The pair of refrigerant pipes that connects an ice machine head to its remote condenser or condensing unit: a liquid line plus a discharge or suction line. Makers sell pre-charged line sets in fixed lengths and limit the run (for its remote-condenser machines Manitowoc allows a calculated run of up to 100 ft, with no more than 35 ft of rise and 15 ft of drop).

Also called: refrigerant lines, pre-charged line set

See also: Remote condenser, Condensing unit, QuietQube, Remote low side

Liquid line valve

A solenoid valve in the line that carries liquid refrigerant to the expansion valve. On many remote systems it closes when the machine stops so the compressor can pump the refrigerant out of the low side (Scotsman remotes do this), and Hoshizaki cubers keep it closed during harvest; if it fails to open, the evaporator starves and freeze cycles run long.

Also called: liquid line solenoid valve, LLSV, LLV

See also: Expansion valve (TXV), Remote low side, Receiver, Filter-drier

LuminIce

Manitowoc's growth-inhibitor accessory: it circulates the air in the ice machine's food zone past an ultraviolet bulb to slow the growth of common microorganisms on exposed surfaces. The bulb is replaced every year (the control can show a reminder after 12 months), an X in an Indigo NXT model number marks the option, and it doesn't replace cleaning and sanitizing.

Also called: LuminIce II, UV growth inhibitor

See also: Sanitizing, Slime, Indigo NXT

Guide: How to clean and sanitize a commercial ice machine (and how often)

Back to the letter index

M

Model number

The maker's code for a machine design, printed on the data plate and the spec sheet. It usually encodes the series, approximate output, ice type, cooling type (often A for air-cooled and W for water-cooled) and electrical supply; parts manuals are organized by it, and you can type one into the search to find the machine's page. Manitowoc's digits give the output at 70 °F air and 50 °F water, not at the 90/70 rating.

See also: Serial number, Data plate, Supersession, AHRI rating conditions (90 °F air / 70 °F water), Indigo NXT, Koolaire

Back to the letter index

N

Nickel-safe cleaner

An ice machine scale remover formulated not to attack nickel plating. Many cube machines, Scotsman's among them, have nickel-plated copper evaporators, and the wrong acid can strip the plating so that ice sticks and harvests poorly; use the cleaner the manual names.

Also called: nickel-safe ice machine cleaner

See also: Descaling, Evaporator, Scale, Sanitizing

Guide: How to clean and sanitize a commercial ice machine (and how often)

NSF/ANSI 12

The NSF/ANSI standard for automatic ice making equipment: food protection and sanitation requirements for how ice machines are designed and built and the materials they use. Food codes accept equipment certified to an ANSI-accredited sanitation standard like this one, so look for a sanitation certification mark, such as NSF's, on the machine.

Also called: NSF 12, NSF certified

See also: Sanitizing, Bin, Dispenser

Nugget ice

Soft, chewable pellets made by compressing flake ice through the extruding head at the top of the auger, popular in healthcare and for soft and blended drinks. Hoshizaki calls its version Cubelet; Scotsman and Manitowoc call theirs nugget ice.

Also called: chewable ice, pellet ice, pebble ice, Sonic-style ice

See also: Flake ice, Cubelet, Continuous ice machine, Auger, Extruding head, Dispenser

Browse: Hoshizaki, Manitowoc, Scotsman, Ice-O-Matic and Follett ice machines

Back to the letter index

O

O-ring

A rubber ring that seals a joint between two parts, such as a water fitting, a pump housing or an auger's bearing housing. A hardened, cracked or pinched O-ring leaks water; it is replaced with one of the same size and material, food-grade where it touches the water that becomes ice.

Also called: o ring, seal ring

See also: Water pump, Auger

Browse: Hoshizaki, Manitowoc, Scotsman, Ice-O-Matic and Follett gaskets & seals

OEM

Original equipment manufacturer: the company that made the machine, so "OEM parts" are the ones it supplies under its own part numbers, often called genuine parts. They usually cost more than compatible parts and are the safer choice for controls, sensors and repairs under warranty.

Also called: genuine part, original part, OEM part

See also: Aftermarket part, Supersession, Model number

Guide: OEM vs aftermarket ice machine parts: price gap and when each makes sense

Overload

A protector on the compressor that opens if the compressor overheats or draws too much current, then closes again once it cools. A compressor that keeps cycling on its overload usually has a start-component, voltage, airflow or refrigerant problem.

Also called: overload protector, thermal overload

See also: Compressor, Start relay, Capacitor

Browse: Hoshizaki, Manitowoc, Scotsman, Ice-O-Matic and Follett relays & capacitors

Back to the letter index

P

Pearl Ice

Ice-O-Matic's name for the ice its GEM machines make: its installation manual decodes GEM as "Modular Pearl Ice", MFI as "Modular Flake Ice" and HEM as "Modular Hard Ice". GEM machines are continuous (auger) machines, like the machines other makers sell for nugget ice, but the Ice-O-Matic documents we read don't call Pearl Ice nugget ice.

Also called: Modular Pearl Ice

See also: Nugget ice, Flake ice, Continuous ice machine

Guide: Cube vs nugget vs flake ice: the ice types and the machines that make them

Potable water

Drinking-quality water that the machine turns into ice, plus the water it dumps or purges each cycle to carry minerals away; DOE rates potable water use in gallons per 100 lb of ice. It is separate from condenser water, which only cools a water-cooled condenser.

Also called: potable water use, ice-making water

See also: Condenser water, Dump valve, Pump-out, Water filter

Prodigy

Scotsman's Prodigy series of cube, flake and nugget machines (including Prodigy Plus and Prodigy ELITE), whose controller has a one-character code display: mostly letters for normal states (F freeze, H harvest, b bin full) and numbers for faults, while E means the controller failed its self-test.

See also: Error code, Control board

Guide: Scotsman ice machine error codes: Prodigy code display meanings and fixes

Browse: Scotsman ice machines

Pump-out

A short drain step on Hoshizaki cubers at the end of the freeze: for 10 to 20 seconds the water pump empties the water tank, by running in reverse or with a drain valve open, depending on the model, carrying away the minerals left in the water. A setting on the control board makes it happen every cycle or every 10 cycles.

Also called: pump-out cycle, drain cycle

See also: Dump valve, Water pump, Sump, Scale, Potable water

Guides: Hoshizaki ice machine beeping? What 1, 2, 3, 6 and 7 beeps mean (error codes), Ice machine water pump: symptoms, testing and replacement

Browse: Hoshizaki, Manitowoc, Scotsman and Ice-O-Matic water pumps

Back to the letter index

Q

QuietQube

Manitowoc's remote low-side ice machines: the head indoors holds only the evaporator and water system, while the compressor and condenser sit in a CVD condensing unit outdoors or on the roof, keeping their heat and noise outside. The CVD units harvest with refrigerant vapor from the receiver rather than compressor hot gas, and work only with matching Manitowoc heads.

See also: Remote low side, Condensing unit, Line set, Indigo NXT, Receiver

Browse: Manitowoc ice machines

Back to the letter index

R

R-290

Propane used as a refrigerant: no ozone depletion, a GWP of 3 and good efficiency, but flammable (ASHRAE safety class A3). EPA allows it only in new ice machines built for it with the whole refrigeration system in one cabinet, with limits on charge size and required warning labels. Servicing it calls for technicians trained for flammable refrigerants and suitable tools; EPA Section 608 certification doesn't cover it in these machines.

Also called: propane, R290, hydrocarbon refrigerant

See also: Global warming potential (GWP), R-404A, EPA Section 608, Sealed system

R-404A

An HFC refrigerant blend (R-125, R-143a and R-134a) used in commercial ice machines for decades, with a GWP of about 3,900. Under the AIM Act it can't be used in self-contained ice machines made from 2026 or 2027 (depending on size) or in remote machines installed from 2027; existing R-404A machines can still be serviced.

Also called: 404A, R404A

See also: Global warming potential (GWP), R-290, EPA Section 608

Receiver

A tank in the liquid line, standard on remote systems, that stores the liquid refrigerant the system isn't using at the moment, including the extra charge a remote condenser needs in cold weather. On Manitowoc remote machines it also supplies vapor for the harvest: through the HPR valve on remote-condenser models, and as the harvest gas on QuietQube.

Also called: receiver tank, liquid receiver

See also: Head pressure control valve, Remote condenser, QuietQube, Liquid line valve, Harvest pressure regulating valve (HPR)

Regular cube

Manitowoc's largest standard cube, 1-1/8 × 1-1/8 × 7/8 in, about 32 cubes to the pound.

See also: Dice cube, Half dice cube, Cube ice

Remote condenser

An air-cooled condenser installed away from the ice machine, usually outdoors or on the roof, and connected to it by a refrigerant line set. It keeps the heat and fan noise out of the kitchen or bar without the water cost of a water-cooled machine, at a higher installation cost, and it needs a head pressure control valve for cold weather.

Also called: remote-cooled, remote air-cooled condenser

See also: Line set, Head pressure control valve, Receiver, Remote condensing, Remote low side, Air-cooled condenser, Harvest pressure regulating valve (HPR)

Guide: Air-, water- or remote-cooled ice machine? Running costs compared

Browse: Hoshizaki, Manitowoc, Scotsman, Ice-O-Matic and Follett condensers

Remote condensing

DOE's equipment class for ice makers whose ice-making mechanism and condenser or condensing unit are "in separate sections". It covers both remote-condenser machines, with the compressor in the head, and remote low-side systems, in which the compressor is remote as well.

Also called: RCU, remote condensing unit, remote

See also: Remote condenser, Remote low side, Ice-making head, Condensing unit

Guide: Air-, water- or remote-cooled ice machine? Running costs compared

Remote low side

A split system with both the compressor and the condenser outside in a condensing unit, leaving only the evaporator, or "low", side of the refrigeration system in the ice machine head. It is the quietest and coolest option indoors; Manitowoc's QuietQube is the best-known example, and DOE classes it as remote condensing with a remote compressor.

Also called: remote compressor, split system

See also: QuietQube, Condensing unit, Remote condensing, Line set

Back to the letter index

S

Safe mode

An Indigo NXT fallback, alert E31: when a water level probe or the ice thickness probe fails, the controller keeps the machine making ice for a while using its model data and the timing of earlier cycles, until the probe is fixed.

Also called: E31

See also: Ice thickness probe, Water level probe, Error code, Indigo NXT

Guide: Manitowoc ice machine error codes (Indigo NXT E01 to E31): meanings and fixes

Sanitizing

Killing the bacteria, yeast and mold in the machine and bin with an approved sanitizer, usually a quaternary ammonium or chlorine (sodium hypochlorite) solution at the strength the maker specifies. It follows descaling in a cleaning and must reach every surface the water and ice touch, including the bin; rinse the acid cleaner out first and never mix the two, because together they give off toxic chlorine gas.

Also called: sanitation, disinfecting, ice machine sanitizer

See also: Descaling, Slime, Nickel-safe cleaner, NSF/ANSI 12, LuminIce

Guide: How to clean and sanitize a commercial ice machine (and how often)

Scale

Hard mineral deposits, mostly calcium and magnesium compounds, that build up because minerals concentrate in the water left behind as ice freezes. Scale coats the evaporator, probes, valves and pump, slows the harvest and clouds the ice; a water filter with scale inhibitor, the right purge setting and regular descaling keep it down.

Also called: lime, limescale, mineral buildup

See also: Descaling, Water hardness, Water filter, Dump valve

Guide: How to clean and sanitize a commercial ice machine (and how often)

Sealed system

The closed refrigerant circuit: compressor, condenser, expansion valve, evaporator and the tubing and valves between them. Work that opens it (a compressor, evaporator or valve change, or a leak repair) means recovering the refrigerant and is done by a refrigeration technician: EPA Section 608 certified on HFC machines such as R-404A ones, and trained for flammable refrigerants on R-290 machines.

Also called: refrigeration system, sealed refrigeration system

See also: EPA Section 608, Compressor, Filter-drier, Evaporator, R-290

Self-contained ice machine

A machine with the ice maker and the storage bin in one cabinet; most undercounter ice machines are self-contained, and so are some larger freestanding units. DOE's definition: "the ice-making mechanism and storage compartment are in an integral cabinet".

Also called: SCU, self-contained unit

See also: Ice-making head, Bin, Gourmet ice

Browse: Hoshizaki, Manitowoc, Scotsman, Ice-O-Matic and Follett ice machines

Serial number

The unique number of one machine, on its data plate. It identifies when the machine was built (on some brands the date is coded into it, on newer Manitowoc machines it is printed separately as MFG DT), which matters for warranty claims and for finding the right part when a component changed partway through a model's production; the serial number age tool decodes it.

See also: Model number, Data plate, Supersession

Guide: Ice machine serial number lookup: how old is my Hoshizaki, Manitowoc, Scotsman or Ice-O-Matic?

Slime

The jelly-like film of bacteria, yeast and mold that grows on wet surfaces in the machine and bin, especially near bread, beer or other sources of airborne yeast. Scrubbing the parts during a cleaning removes it and sanitizing kills what is left; a scale remover alone does not.

Also called: biofilm

See also: Sanitizing, Descaling, NSF/ANSI 12, LuminIce

Guide: How to clean and sanitize a commercial ice machine (and how often)

Start relay

The relay that connects a single-phase compressor's start capacitor or start winding for the first moment of a start and then disconnects it; it may be a current relay, a potential relay or a solid-state PTC device. A failed one leaves the compressor humming and tripping its overload instead of starting.

Also called: potential relay, current relay, PTC start device

See also: Capacitor, Compressor, Overload, Contactor

Browse: Hoshizaki, Manitowoc, Scotsman, Ice-O-Matic and Follett relays & capacitors

Sump

The water trough or reservoir at the bottom of a cube machine's water system, filled by the water inlet valve and pumped up over the evaporator during the freeze cycle. The float switch or water level probe sits in it, and the dump valve or a pump-out empties it.

Also called: water trough, reservoir, water tank

See also: Water pump, Float switch, Water level probe, Dump valve, Pump-out, Water inlet valve

Supersession

When a maker replaces a part number with a new one, the old number is "superseded", and orders for it ship the new part, which may look different or come as a kit with new connectors. Sellers often list both numbers ("replaces …"); check the cross-reference before assuming two numbers are interchangeable.

Also called: superseded part, replacement part number

See also: OEM, Aftermarket part, Model number, Serial number

Back to the letter index

T

Thaw cycle

An Indigo NXT recovery routine for a failed harvest: if the curtain or ice damper hasn't opened after 7 minutes of harvest, the compressor and harvest valve stop and the machine circulates, dumps and refills water 18 times (about an hour) to melt the ice off, then starts a new freeze. A curtain held open for 30 seconds during it means a full bin and shuts the machine off.

See also: Harvest, Water curtain, Error code, Indigo NXT

Guide: Manitowoc ice machine error codes (Indigo NXT E01 to E31): meanings and fixes

Thermistor

A temperature sensor whose electrical resistance changes with temperature, fixed to a refrigerant line or placed in the water or bin. The board uses it to time the harvest (on Hoshizaki cubers one on the suction line tells the board the evaporator has warmed to about 48 °F, and an adjustable timer then finishes the harvest) or to guard against overheating; it is tested unplugged, by comparing its resistance at a known temperature with the manual's table.

Also called: temperature sensor, harvest thermistor, evaporator thermistor

See also: Harvest, Control board, Ice thickness probe, KM series, Anti-slush

Guide: Ice thickness probe and thermistor: how ice machines decide when to harvest

Browse: Hoshizaki, Manitowoc, Scotsman, Ice-O-Matic and Follett thermistors & sensors

Transformer

The control transformer steps the line voltage down to the low voltage that some control boards, relays and sensors run on. When it fails the board goes dark even though the machine has power, so a technician checks its output before the board is replaced.

Also called: control transformer

See also: Control board, Contactor

Browse: Hoshizaki, Manitowoc, Scotsman and Ice-O-Matic transformers

Back to the letter index

W

Water curtain

A hinged plastic panel in front of the evaporator on Manitowoc, Scotsman and similar cubers that keeps the water on the plate during the freeze. At harvest the falling ice swings it open, which opens the curtain switch and tells the board the ice has dropped; if ice in a full bin holds it open, the machine stops.

Also called: curtain, ice damper, splash curtain

See also: Bin control, Harvest, Ice bridge, Thaw cycle

Guide: Manitowoc ice machine error codes (Indigo NXT E01 to E31): meanings and fixes

Water filter

A cartridge filter on the incoming water line that removes sediment and chlorine taste and odor and, with a scale inhibitor (often polyphosphate), slows scale. Change cartridges on schedule, commonly every six months, or sooner if the flow drops; a filter reduces scale but does not stop it, so descaling is still needed.

Also called: water filtration system, filter cartridge

See also: Scale, Water hardness, Potable water, Descaling

Guide: How to clean and sanitize a commercial ice machine (and how often)

Browse: Manitowoc, Ice-O-Matic and Follett water filters

Water hardness

The amount of dissolved calcium and magnesium in water, given in milligrams per liter (about the same as ppm) or grains per gallon as calcium carbonate; 1 grain per gallon is about 17.1 mg/L. USGS calls water above 120 mg/L (about 7 gpg) hard and above 180 mg/L (about 10.5 gpg) very hard, and harder water means more scale and more frequent descaling.

Also called: hardness, grains per gallon, gpg

See also: Scale, Water filter, Descaling

Water inlet valve

The solenoid valve where the water supply enters the machine: the board opens it to fill the trough (and on some machines to assist the harvest), and a spring closes it. If it fails shut the machine gets no water; if it leaks through, water keeps entering during the freeze, so freeze cycles run long and the ice comes out cloudy or uneven.

Also called: fill valve, water solenoid valve, inlet valve

See also: Dump valve, Sump, Float switch, Water filter, Harvest assist

Guide: Ice machine water inlet valve: symptoms, testing and replacement

Browse: Hoshizaki, Manitowoc, Scotsman, Ice-O-Matic and Follett water inlet valves

Water level probe

Metal probes that sense the water level in the trough by its electrical conductivity, with no moving parts; many Manitowoc and Scotsman Prodigy cubers use them instead of a float switch. Scale or slime bridging the probes makes them read wrong, so they are cleaned at every descaling.

Also called: water level sensor, water level control

See also: Float switch, Sump, Scale, Safe mode

Guide: Ice machine float switch and water level probe: symptoms, testing and replacement

Browse: Hoshizaki, Manitowoc, Scotsman, Ice-O-Matic and Follett float switches

Water pump

The small pump that lifts water from the trough to the distribution tube so it flows over the evaporator during the freeze cycle; on Hoshizaki cubers it also empties the tank in the pump-out step. A failing pump gives thin, cloudy or partly formed cubes and long freeze cycles.

Also called: circulation pump, recirculating pump, pump motor

See also: Distribution tube, Sump, Evaporator, Dump valve, Pump-out, Anti-slush

Guide: Ice machine water pump: symptoms, testing and replacement

Browse: Hoshizaki, Manitowoc, Scotsman and Ice-O-Matic water pumps

Water regulating valve

On water-cooled machines, a valve that opens and closes with head pressure to let just enough water through the condenser to hold the pressure in range. One that leaks through wastes water while the machine is off; one that doesn't open far enough lets head pressure climb.

Also called: water regulator, condenser water valve

See also: Water-cooled condenser, Condenser water, Head pressure

Water-cooled condenser

A condenser cooled by water flowing through it instead of air: quiet and much less affected by a hot room, but on a once-through system it sends a large volume of water down the drain, and some water utilities and local codes restrict that. It makes most sense where air cooling is impractical or the building has a closed-loop water supply such as a cooling tower.

Also called: water-cooled ice machine

See also: Condenser water, Water regulating valve, Condenser, High pressure cut-out

Guide: Air-, water- or remote-cooled ice machine? Running costs compared

Browse: Hoshizaki, Manitowoc, Scotsman, Ice-O-Matic and Follett condensers

Back to the letter index

Sources

Last updated