Skip to content
IcePartsDB

Ice machine float switch and water level probe: symptoms, testing and replacement

By IcePartsDB · Updated · 8 min read

In this guide · 9 sections
  1. What the float switch and water level probe do
  2. Signs the float switch or probe is failing
  3. How to check it
  4. Finding the right part number
  5. Most-listed float switches and water level probes
  6. OEM or compatible?
  7. Replacing a float switch or water level probe
  8. Questions and answers
  9. Sources

Short answer: The float switch or water level probe tells the control board how much water is in the trough. Hoshizaki crescent cubers use a float switch, which also ends the freeze cycle when the water level drops; Manitowoc Indigo NXT and S-model cubers and Scotsman Prodigy cubers use water level probes that sense water by its conductivity; some machines, such as Scotsman's flake and nugget machines, fill through a mechanical float valve. When the sensor sticks, gets coated in scale or fails, the machine fills wrongly, won't start the next step, ends the freeze too early or too late, or locks out. Clean it first, test a float switch with a meter, and replace it by the number on the old part.

What the float switch and water level probe do

The control board needs to know how much water is in the trough or reservoir, to stop the fill, to make sure there is water before it runs the pump and compressor and, on some machines, to end the freeze. The makers do this in three ways:

  • Float switch (Hoshizaki). Hoshizaki crescent cubers have a float that rides up and down a shaft in the water tank and switches a contact: open with the tank empty, closed with it full. After the 1-minute fill and after each harvest, the board checks that the switch is closed (enough water). In the freeze cycle the float switch also ends the freeze: as water turns to ice on the evaporator, the level in the tank drops, and when the switch opens (after a 5-minute minimum and a 15-second delay) the board starts the harvest. So a sticking float on a Hoshizaki affects both the water supply and the cube size. Hoshizaki cubelet machines such as the FS-1022MLH-C also use a float switch.
  • Water level probes (Manitowoc, Scotsman Prodigy). Metal probes with no moving parts that detect water by its electrical conductivity. A Manitowoc Indigo NXT has a low and a high probe and fills until the water touches both; Scotsman Prodigy cubers fill when the mid-length probe of their water level sensor is uncovered and stop when the top probe touches water. On these machines the freeze ends on the ice thickness probe instead (see the ice thickness probe and thermistor guide).
  • Mechanical float valve. Some machines let water in through a float valve that opens as the level drops: Scotsman's Prodigy Plus flake and nugget machines (where a conductivity probe beside the reservoir tells the controller water is present) and some older Manitowoc models, such as the Q1400C QuietQube.

Scotsman's water level and ice thickness sensors are conductivity probes, and Scotsman says its Prodigy cubers can be supplied with reverse osmosis (RO) water only if the water's conductivity is at least 10 microsiemens/cm.

Signs the float switch or probe is failing

What you see What the sensor may be doing
The trough fills but the machine never moves on to the harvest or freeze Not reporting "full": float stuck down, failed switch, scaled or dirty probes
Water keeps running in during the freeze cycle Not reporting "full", so the inlet valve stays open (on probe machines)
Short freeze cycles and small or thin cubes (Hoshizaki) Float dropping too early (sticking, scale), or water draining away through a leaking drain valve
Very long freeze cycles, thick ice, or the Hoshizaki 3-beep freeze alarm Float stuck in the "full" (up) position
The machine stops on a water or cycle fault now and then Intermittent switch, loose connector, scale, or (Scotsman) water with too little conductivity

On a Hoshizaki, water overflowing to the drain during the 1-minute fill and the harvest is normal, not a float fault. For cube size problems with other causes, see small, thin, thick or cloudy cubes. If the machine shows a code, look it up in the Hoshizaki, Manitowoc, Scotsman or Ice-O-Matic error code guide.

How to check it

Switch off and unplug the machine before reaching inside.

  1. Clean it. Remove the float or probe and clean off scale and slime with the maker's ice machine cleaner, diluted as the manual says (Hoshizaki: 1 part Scale Away to 25 parts warm water for the float switch; Manitowoc: 2 ounces of de-scaler to 16 ounces of water for its probes, without soaking the electrical connectors). Rinse well. A float that slides freely and clean probe surfaces fix many "failed" sensors.
  2. Check the float moves. It should slide the full length of its shaft without catching. A cracked float that has filled with water won't rise.
  3. Test a float switch with a meter. Hoshizaki's check: drain the tank, unplug the float switch from the control board (the black K5 connector) and check continuity across its leads. With the tank empty it should be open; with the tank full, closed. A switch that stays closed when empty needs cleaning or replacing.
  4. Check the wiring. Look for a corroded connector or a pinched wire, especially if the fault comes and goes.
  5. Probes: they have no moving parts to test by hand. Clean them, check the wire and connector, and follow the service manual's diagnostic steps; many controls show the water level reading or light an indicator when the probe senses water.

Finding the right part number

  • Read the number on the old sensor or its wire tag, or find it in the parts manual for your model (how to find the model and part number).
  • Floats look alike but differ in length, switch type (normally open or closed) and connector, so match the number.
  • Makers replace sensor numbers with newer kits over time; listings that say "replaces …" usually cover the old number too.

Type the number into the search box at the top of the page; dashes and spaces don't matter.

Most-listed float switches and water level probes

Most-listed float switches on eBay, with typical prices
Part numberBrandPartListingsSellersTypical priceFromSold as compatibleModels sellers name
000012651ManitowocFloat Switch9524$52.09$50.2998%—
000012649ManitowocFloat Switch8827$55.74$42.8099%—
000016053ManitowocFloat Switch5028$35.06$34.0598%—
040002396ManitowocFloat Switch3424$31.47$24.2482%—
040001783ManitowocFloat Switch2722$28.51$23.4178%—
4A3624-01HoshizakiFloat Switch2722$29.69$17.4556%10
A39030-021ScotsmanFloat Switch2116$35.77$16.9995%—
11-0539-51ScotsmanFloat Switch2018$29.22$21.4150%—
P00816-01HoshizakiFloat Switch2016$103$79.9980%—
426799-01HoshizakiFloat Switch1816$24.99$15.0089%—
2006549ManitowocFloat Switch1715$19.54$16.2565%—
435490-01HoshizakiFloat Switch1715$40.99$39.0065%—
Live eBay listings that ship to the US, prices including stated shipping, checked 2026-11-23. Typical price is the median of a part's listings; "sold as compatible" is the share of its listings that say compatible, replacement for or fits. All float switches we track: Hoshizaki (11) · Manitowoc (12) · Scotsman (18).

OEM or compatible?

Share of eBay listings sold as compatible or aftermarket, and median prices, by part type
Part typeListingsSold as compatible / aftermarketMedian, OEM or not statedMedian, compatible / aftermarketDifference
Float Switches57870%$56.90$52.029% less
Active eBay part listings for Hoshizaki, Manitowoc and Scotsman parts that ship to the US, totals including stated shipping. "Compatible / aftermarket" means the title says so (compatible, replacement for, fits …); the rest say OEM or don't say. Multi-packs are left out, and a median is shown only with at least 8 listings on that side.

The table shows the current share of compatible listings and the median price of each kind. If you buy a compatible switch, check that the length, the connector and the switch type match the original: a float mounted even a fraction of an inch higher or lower changes the water level. See OEM vs aftermarket ice machine parts.

Replacing a float switch or water level probe

  1. Switch off and unplug the machine and drain the trough.
  2. Unplug the sensor's connector from the control board (or the harness), noting the position. On Hoshizaki boards the float switch and the thermistor use the same type of connector, so don't swap them.
  3. Remove the float or probe from its bracket.
  4. Fit the new one in exactly the same position and height, and route the wire away from moving parts.
  5. Refill and run a full cycle; check that the fill stops at the right level and the cycle moves on.

Clean the sensor at every scheduled cleaning: see how to clean a commercial ice machine.

Questions and answers

Where is the float switch on a Hoshizaki ice machine?

In the water tank under the evaporator: a float rides up and down a shaft there and switches a contact, open when the tank is empty and closed when it is full. On crescent cubers it also ends the freeze, when the level drops as the water turns to ice. Switch off and disconnect the power before you reach into the machine.

How do I know if my ice machine float switch is bad?

If the trough fills but the machine never moves on to the next step, or the freeze cycles are much too short or too long, the float switch or probe is a prime suspect. Clean it and make sure the float moves freely; then test the switch with a meter. On a Hoshizaki it should be open with the tank empty and closed with the tank full. A switch that doesn't change has failed.

Can I clean a float switch instead of replacing it?

Often, yes. Scale and slime stop the float from moving and coat the switch. Clean it with the maker's ice machine cleaner at the dilution in the manual, rinse, and check that it slides freely before deciding it has failed.

What does a water level probe do on a Manitowoc ice machine?

It tells the control board when the water trough is full, by sensing the water's conductivity. An Indigo NXT has a low and a high probe, fills until the water touches both, and tops up once during the freeze. Scale on the probe gives false readings, so clean it during every cleaning.

Does a Hoshizaki float switch control the cube size?

Yes, on Hoshizaki crescent cubers. The freeze ends when the float switch opens as the water level in the tank drops, so a float that sticks low gives short freezes and small cubes, and one that sticks high gives long freezes, thick ice and, after two long cycles in a row, the 3-beep freeze timer alarm.

Can I use reverse osmosis water in a Scotsman ice machine?

Scotsman says its Prodigy cubers can be supplied with RO water as long as the water's conductivity is no less than 10 microsiemens/cm. Their water level and ice thickness sensors detect water by its conductivity.

How much does an ice machine float switch cost?

Live eBay prices for float switches and water level probes for Hoshizaki, Manitowoc and Scotsman machines are mostly $35.02 to $55.99 (median $52.09, from 578 live eBay listings including shipping, checked 2026-11-23). The tables above break this down by part number and brand.

Sources

More guides

Data sources

  • eBay listings (Browse API search results) — part numbers, listing counts and prices, refreshed several times a day
  • IcePartsDB editorial — written from the data above, the sources linked in the text and general trade practice; not a substitute for the machine's manual or a qualified technician
  • How we build these pages (methodology)
  • Report a correction to this page

Last updated