Air-, water- or remote-cooled ice machine? Running costs compared

By IcePartsDB · Updated · 6 min read

In this guide · 9 sections
  1. How each type gets rid of heat
  2. What each one costs to run
  3. ENERGY STAR and rebates
  4. When an air-cooled machine makes sense
  5. When a water-cooled machine makes sense
  6. When a remote-cooled machine makes sense
  7. Refrigerant and installation
  8. Questions and answers
  9. Sources

Short answer: For most kitchens an air-cooled machine is the cheapest to run. A water-cooled machine uses less electricity, but with single-pass cooling it sends its condenser water down the drain (EPA puts the total at 100 to 300 gallons per 100 lbs of ice), and at typical U.S. water and sewer rates that water costs many times what the machine saves on power. Only air-cooled machines, including remote-cooled ones, can be ENERGY STAR certified. A remote-cooled machine costs a little more to run and a lot more to install, but it moves the heat and most of the noise out of the room.

The cooling type decides where an ice machine's heat goes, and that drives its running cost, where it can go, and what it costs to install. This guide compares air-, water- and remote-cooled machines on the energy and water figures their makers certified to the U.S. Department of Energy.

How each type gets rid of heat

An ice machine is a refrigeration system: it pulls heat out of water to freeze it, and it has to put that heat somewhere. The cooling type is where the heat goes.

  • Air-cooled: a fan blows room air across the condenser, so the heat ends up in the room. The machine needs free space around its vents and a room that doesn't get too hot. It makes less ice as the room gets warmer.
  • Water-cooled: water runs through the condenser and carries the heat away. In the simplest (single-pass) installation it then goes straight to the drain; with a closed loop it is cooled by a chiller or cooling tower and reused. The room stays cooler and quieter, and output holds up better in a hot room.
  • Remote-cooled: the condenser and its fan sit outside, usually on the roof or an outside wall, connected to the ice machine by refrigerant lines. The heat and the fan noise stay outdoors.

What each one costs to run

The table compares machines of the same size, using the energy and water figures their makers certified to the U.S. Department of Energy.

Yearly running cost by cooling type, one 500 lbs/day machine
TypeModelsENERGY STARkWh / 100 lbsCondenser water, gal / 100 lbsElectricity / yearCondenser water / yearTotal / year
Air-cooled ice-making head23586 of 2355.00—$514 (3,833 kWh)—$514
Water-cooled ice-making head650 of 654.11135$422 (3,150 kWh)$1,552 (103,478 gal)$1,975
Remote-cooled (remote condenser)7816 of 785.38—$553 (4,124 kWh)—$553
One machine rated 500 lbs/day making 210 lbs of ice a day (it makes ice 42% of the day, DOE's duty cycle), using the median energy and condenser water of the 378 DOE / ENERGY STAR models rated 400–700 lbs/day. Electricity at $0.1341/kWh (EIA 2025 U.S. commercial average); water and sewer at $15 per 1,000 gal (assumption: combined water and sewer, as DOE prices it (88 FR 30508 §IV.F.5); local rates vary, so use your bill). Every type also uses ice-making water, about 14–19 gal per 100 lbs (middle half of models), so it is left out. Compare models: Hoshizaki machines · Manitowoc machines · Scotsman machines.

Water-cooled machines use the least electricity, but the condenser water is most of what they cost to run. Remote-cooled systems in this size range use a little more electricity than air-cooled heads, and they cost more to buy and install.

These figures come from the DOE test, which uses the standard ratings of AHRI Standard 810: 90 °F air and 70 °F water. Brochures and spec sheets often also quote a higher output measured at 70 °F air and 50 °F water, which Scotsman calls "ideal conditions". A machine in a hot room or fed with warm water makes less ice and uses more energy per pound, so treat the table as a fair comparison rather than a bill forecast. Each machine page has the same estimate for that exact model, and you can enter your own electricity and water rates there. To compare up to three machines a year and over their life, against ENERGY STAR models of their size, use the running-cost calculator.

ENERGY STAR and rebates

ENERGY STAR (Version 3.0, in effect since January 28, 2018) certifies only air-cooled ice makers: air-cooled ice-making heads, self-contained units and remote condensing units. Water-cooled ice makers are excluded, along with ice makers with ice and water dispensing systems. If a utility rebate requires ENERGY STAR certification, a water-cooled machine won't qualify; check the ENERGY STAR column in the table and the rebate's own rules.

When an air-cooled machine makes sense

Air-cooled is the default choice for most restaurants, bars, offices and hotels:

  • It costs the least to buy and to run, and needs only a power outlet, a water line and a drain.
  • It needs room to breathe, and a clean condenser and working fan motor (Hoshizaki, Manitowoc and Scotsman condenser fan motors; see the condenser fan motor guide). EPA's WaterSense guidance says air-cooled machines typically need at least 6 inches of clearance around the air intake and discharge, and suit rooms at 80 °F or below; the installation manual gives the exact clearances and room temperatures for your model. A machine squeezed into a hot, closed space makes less ice and wears faster.
  • In summer, the heat it puts into the room is extra work for your air conditioning.

When a water-cooled machine makes sense

EPA's WaterSense program recommends water-cooled machines only where the location requires one, such as a room that is consistently above 80 °F or too tight for an air-cooled machine to get enough air, and only when the machine can be connected to a recirculating (closed-loop) cooling water system:

  • The room is hot, cramped or dusty, and a remote condenser can't be installed.
  • The building has a recirculating cooling water loop or cooling tower. Ask the installer whether the machine can run on it, because the condenser water then isn't wasted.
  • Single-pass cooling sends the water to the drain. EPA puts the total water use of single-pass water-cooled machines at 100 to 300 gallons per 100 lbs of ice, against less than 50 gallons for air-cooled ones. Check your water utility's and building code's rules before installing one.

When a remote-cooled machine makes sense

  • The kitchen or bar is open to customers, or already too hot, and you want the heat and fan noise outside.
  • The machine is large: a big air-cooled machine puts a lot of heat into a room.
  • Budget for the condenser, the refrigerant line set and the installation. Remote condensers are replaced as their own part: Hoshizaki, Manitowoc and Scotsman condensers.
  • Many remote machines are designed to pair with a specific condenser model. Where the data names it, the machine page links to that condenser.

Refrigerant and installation

The refrigerant lines of a remote system are installed by a refrigeration technician. Machines with an HFC refrigerant such as R-404A need a technician certified under EPA Section 608 for refrigerant work. Some newer self-contained machines use R-290 (propane), which is flammable: Manitowoc says some of its R-290 models need a minimum room size (shown on the machine's label), that the combined charge of several R-290 machines in one room must be considered, and that only technicians with flammable refrigerant training may work on them. The nameplate shows the refrigerant; see ice machine refrigerants and the EPA rules. For the wider picture, see Hoshizaki vs Manitowoc vs Scotsman and how to size an ice machine.

Questions and answers

Is a water-cooled ice machine cheaper to run?

Not usually. It uses less electricity than an air-cooled machine of the same size, but with single-pass cooling the condenser water it sends to the drain costs more than the power it saves at typical U.S. water and sewer rates. It also can't be ENERGY STAR certified, and EPA's WaterSense program recommends water-cooled machines only on a recirculating cooling loop.

Does an air-cooled ice machine heat up the kitchen?

Yes. The heat it takes out of the water goes into the room, along with the noise of its fan. In a hot room it also makes less ice than its certified rating, which is measured at 90 °F air and 70 °F water.

Can a water-cooled ice machine be ENERGY STAR certified?

No. The ENERGY STAR specification for commercial ice makers (Version 3.0) covers only air-cooled machines, including remote condensing units; water-cooled ice makers are excluded.

Why choose a remote-cooled ice machine?

To keep the heat and the condenser fan noise out of the room. The trade-off is a higher purchase and installation cost, and the refrigerant lines must be installed by a refrigeration technician (EPA Section 608 certified for HFC refrigerants such as R-404A).

Where can I see a specific machine's energy and water use?

Every machine page on IcePartsDB shows the model's rated harvest, energy use (kWh per 100 lbs of ice) and water use from the DOE and ENERGY STAR data, with a yearly running-cost estimate you can adjust to your local rates.