Skip to content
IcePartsDB

Ice-O-Matic ice machine error codes: CIM flashing lights, GEM and MFI service lights

By IcePartsDB · Updated · 13 min read

In this guide · 7 sections
  1. CIM cuber lights
  2. CIM error codes 1 to 7
  3. GEM, MFI and HEM indicator lights
  4. GEMU090 undercounter nugget machine
  5. CIMU undercounter cubers
  6. Questions and answers
  7. Sources

Short answer: Ice-O-Matic CIM cubers show errors as flash patterns of the Power light (red) and the Clean light (yellow). Error 1 (quick red flash) is a freeze cycle that ran past 1 hour, 2 (slow red flash while off) a failed sump thermistor, 3 (red and yellow quick flash) a water fill that took over 5 minutes, 4 a purge over 2 minutes, 5 (double red) a harvest over 7.5 minutes, 6 (triple red) a long freeze and a long harvest, and 7 (triple red and yellow) a water level error. Hold Power and Clean together for 3 seconds to clear the codes. GEM (Pearl Ice), MFI (flake) and HEM (hard ice) machines have no numbered codes; a blinking red Service light means the auger motor drew too much current and the machine will retry, a steady one that it has locked out (switch the power off and on).

Ice-O-Matic's modular machines don't have a code display. Each family signals faults with lights instead: the CIM Elevation Series cubers with flash patterns of two lights, the GEM (Pearl Ice), MFI (flake) and HEM (hard ice) machines with a row of indicator lights on the control board. This guide covers what Ice-O-Matic's own manuals say each signal means, what to check and how to reset, for:

  • CIM Elevation Series modular cubers (CIM0320 to CIM2047), from the CIM Service Manual of May 2026;
  • GEM (Pearl Ice), MFI (flake) and HEM (hard ice) modular machines, from the GEM, MFI & HEM Service Manual of May 2026, whose tables name GEM and MFI models only;
  • the GEMU090 undercounter nugget machine and the CIMU220 and CIMU300 undercounter cubers, from their installation manuals.

The older ICE series cubers (ICE0250 to ICE2100) have no error codes: their service manual works through troubleshooting trees instead. To find out how old a machine is from its serial number, use the serial number age lookup.

CIM cuber lights

A CIM cuber signals with two lights: the Power light (red when the machine is off, blue when it is on) and the Clean light (yellow). The Power and Clean buttons on the control board do the same as the push pad on the front of the machine. Ice-O-Matic's manual names six flash patterns:

Pattern What it looks like
Solid On constantly
Slow One flash every second
Quick One flash every half second
Double Two flashes, then a 1-second pause
Triple Three flashes, then a 1-second pause
Delayed One flash every 3 seconds

Normal states:

Power light Clean light Meaning
Red, solid Off Machine off
Blue, solid Off Making ice (freeze or harvest), or stopped on a full bin (curtain open or bin thermostat)
Blue, slow Off Rinse; the end of a harvest (harvest verification or default harvest: the board waits for the curtain to open and close); or the 3-minute wait before the machine may restart after stopping on a full bin
Blue, quick Off Manual harvest
Red, solid Yellow, slow Clean cycle running
Red, solid Yellow, solid Clean cycle complete
Red, double slow Diagnostics running

The board also has a cleaning reminder: every 6 months as set at the factory, or every 3 months with switch 3 of the board's adjustment block on (Ice-O-Matic suggests it for hard water). Switch 4 turns the "clean reminder light" off, which Ice-O-Matic doesn't recommend; the manual doesn't say which light shows the reminder. See how to clean a commercial ice machine.

CIM error codes 1 to 7

Error Lights What it means
1 Power light, quick red flash Maximum freeze time: the freeze cycle ran past 1 hour. On control boards from before serial number 2106, also a long harvest, or both
2 Power light, slow red flash, with the machine off Thermistor failure (the sump water temperature sensor)
3 Power light red and Clean light yellow, quick flashes Maximum fill time: the sump didn't fill within 5 minutes. On boards from before serial 2106, a long fill or a long purge
4 Double red and double yellow, quick Maximum purge time: the purge ran past 2 minutes
5 Double red, quick Maximum harvest time: the harvest ran past 7.5 minutes
6 Triple red, quick Maximum freeze (1 hour) and maximum harvest (7.5 minutes)
7 Triple red and triple yellow, quick Water level error: the float didn't close

The time limits behind these codes, from the same manual: freeze 5 minutes minimum and 1 hour maximum; harvest 20 seconds minimum and 7.5 minutes maximum on current boards; water fill 5 minutes maximum; purge 7 seconds minimum and 2 minutes maximum.

Boards from before serial 2106. The manual describes older control boards as "pre 2106 serial": on those the maximum harvest is 5 minutes (the error list says 5.5), error 1 also covers a long harvest, and error 3 also covers a long purge. Ice-O-Matic serial numbers begin with the year and month of manufacture, so 2106 reads as June 2021; the newer boards' tables are headed "from 2106 REV C1".

What Ice-O-Matic says to check

Switch off and disconnect the power before working inside the machine. Voltage checks on the board and anything in the sealed refrigeration system are for a technician. On R-404A and R-449A models (model numbers with no refrigerant suffix or ending in 49), opening the refrigerant circuit needs a technician certified under EPA Section 608. Self-contained R-290 models (numbers ending in 90) are exempt from Section 608 certification, but R-290 is flammable propane: have them serviced only by a technician trained in flammable refrigerants (R-290 rules).

  • Error 1 (long freeze): a high pressure cut-out that opens during the freeze can cause it. Ice-O-Matic lists a dirty or blocked condenser, a failed fan cycle control, a failed fan motor (Ice-O-Matic condenser fan motors), a restriction on the high side or too much refrigerant. R-290 models have no fan cycle control, and their high pressure cut-out opens at 350 psi instead of 450.
  • Ice that forms badly (no code of its own): Ice-O-Matic's evaporator section says improper ice formation can be a water or a refrigeration problem. A dirty water system gives poor water flow over the evaporator; a low refrigerant charge or a restricted expansion valve can show as ice on the bottom of the plate and thin or no ice on the top half.
  • Error 2 (thermistor): the thermistor measures the sump water temperature (it runs the anti-slush pauses of the water pump). Check it and its plug on the board (Ice-O-Matic thermistors & sensors).
  • Error 3 (long fill): the high float switch has to open within 5 minutes. Check the water supply first, then whether the water inlet valve opens when the board powers it, and for blocked supply lines and water filters. A valve whose coil checks good but doesn't open is cleaned or replaced (Ice-O-Matic water inlet valves).
  • Error 4 (long purge): the purge valve on the back of the evaporator should open during harvest and cleaning. If it stays shut while the board powers it, the manual has a technician check the voltage at the valve and at the board.
  • Error 5 (long harvest): the ice slab didn't drop and open the curtain in time. Ice-O-Matic's checks cover the harvest assist and hot gas valve , the magnetic curtain switch (is the magnet on the curtain, is the harness plugged in; try another magnet against the switch, then replace the switch) and the evaporator: if the slab resists coming off the plate, Ice-O-Matic says to look for loss of plating, pitting, mineral build-up and loose horizontal dividers, and recommends a new evaporator if a divider has separated from the base. Boards made after January 2023 also run the water pump once a harvest reaches 5 minutes, to help release the ice.
  • Error 7 (water level): when the pump starts, the water level in the sump drops and the high float switch should close. If it doesn't, check the floats: with both floats down, both float switch lights on the board should be on (Ice-O-Matic float switches). Also check that the water pump runs (Ice-O-Matic water pumps).

Clearing the codes and other button functions

Buttons Machine state What happens
Power and Clean together, 3 seconds Off, or showing an error Clears the error codes and resets the counters (one blue and yellow flash)
Power and Clean together, 6 seconds Off Runs the diagnostics program (press both quickly to step to the next state)
Power, 3 seconds Off Shows the control code revision
Power, quick press Off Starts ice making
Power, quick press Making ice Manual harvest: finishes the cycle, then shuts off
Power, 3 seconds Making ice Immediate harvest, then shuts off
Power, 6 seconds Any Machine off (but the cleaning instructions say a clean cycle can't be stopped once it has started)
Clean, quick press Off Starts a clean cycle

Write the error down before clearing it: Ice-O-Matic's GEM, MFI & HEM and ICE Series manuals ask for the model number, the serial number and a detailed description of the problem in any service communication. The CIM board also has a Bluetooth module that shows the board's state in Ice-O-Matic's mobile app.

GEM, MFI and HEM indicator lights

The GEM (Pearl Ice), MFI (flake) and HEM (hard ice) modular machines have no numbered error codes. The GEM, MFI & HEM Service Manual describes seven lights on the control board. Its title covers HEM machines, but its tables name only GEM and MFI models, so check an HEM machine against its own installation manual and data plate too.

Light Colour Normal What it tells you
WTR-OK Green On Water in the reservoir. Off: the water level fell below the water sensor's tip, and the machine stopped; it restarts when the reservoir refills
PWR-OK Green On The board has power and works
Service Red Off Blinking: the auger motor drew too much current and the machine is waiting to retry. Steady: locked out
Freeze Red On while making ice
Bin Full Red Off while making ice On: ice blocked the ice level sensors for 6 seconds or more and the machine shut down
LED1 White On while making ice Compressor relay
LED2 White On while making ice Auger motor relay

Service light (auger motor overload): when the auger drive motor's current gets too high, the board stops the compressor and the auger motor and blinks the Service light. After 4 minutes it restarts the auger motor; if the current stays within limits for 60 seconds, the compressor restarts too. If not, it tries once more, and if the current is still too high the machine shuts down and the Service light stays on. To reset, switch the machine off and on again. Ice-O-Matic's diagnosis for a shutdown on high auger motor current: look for the cause, including the bearings, the gear motor's condition and scale on the auger and in the evaporator (gear motors, Ice-O-Matic augers). If the auger motor hums but doesn't turn, the auger is stuck and the board hasn't shut it down yet.

Bin Full light on with an empty bin: clean and check the ice level sensors (photo eyes); scale blocks them. After the path between the sensors has been clear for more than 10 seconds, the machine restarts. The compressor never restarts less than 2 minutes after it stopped, and the auger runs for 1 more minute after a shutdown to clear the evaporator.

No ice and nothing runs: Ice-O-Matic's checklist is no power, the master switch off, a low water level (check the water supply, filter, strainer and float valve), blocked ice level sensors, scale on the water level sensor, or an open high pressure control (water flow on water-cooled models, the fan motor on air-cooled ones). Its control system diagnosis, in order:

  1. PWR-OK off: check the power. If there is power and the light is still off, check the high and low pressure cut-outs; if both are closed, replace the board (Ice-O-Matic control boards).
  2. WTR-OK off: check the water level in the reservoir, then that the water sensor is plugged in and its tip isn't corroded (a technician can test it with an ohmmeter).
  3. Bin Full and Service both off and the machine not running: replace the board. Bin Full off with the auger turning and the compressor stopped: check the compressor contactor coil. Bin Full on: the ice sensors may be blocked.
  4. The pressure cut-outs: a technician checks whether either is open and why.

The high and low pressure cut-outs reset themselves once the pressure is back in range; the mode (on-off) switch is not a service disconnect, so switch off at the breaker before opening the machine.

GEMU090 undercounter nugget machine

The GEMU090 has three lights on its control panel, visible with the door open: Ice Making, Check Water and Time to Clean. From its installation guide:

  • Check Water flashing red: no water. Check the water supply; the control checks for water every 20 minutes and starts making ice again by itself once water is back.
  • All lights flashing: the auger motor has overloaded or isn't running; call for service. The guide's technical note: one blink and repeat is an overload, two blinks and repeat an open motor. Reset with the on/off button.
  • Time to Clean on: clean the ice making system. During a descaling cycle (both buttons held for 5 seconds) the Time to Clean light blinks, then glows steadily until the clean is complete.

CIMU undercounter cubers

The CIMU220 and CIMU300 installation manual describes a light and a small display, not error codes. The light is steady red when the machine is off, steady blue when it is on and making ice, and flashing blue while it shuts down. The display shows FUL (with the blue light) when the bin control has stopped the machine on a full bin, h1 during a normal shutdown (it finishes the freeze and the harvest first) and h2 during an accelerated shutdown (it harvests at once, then stops). During a clean cycle the machine shows solid red and flashing yellow. The manual says all service work must be done by authorized service personnel.

Questions and answers

What does a flashing red light mean on an Ice-O-Matic ice machine?

On a CIM cuber, a quick red flash of the Power light is error 1, a freeze cycle that ran for more than an hour; double red is error 5 (a harvest over 7.5 minutes), triple red error 6 (both), and a slow red flash with the machine off is error 2, a failed thermistor. Red with yellow flashes are errors 3, 4 and 7, the water fill, purge and float faults. On a GEM, MFI or HEM machine a blinking red Service light means the auger motor drew too much current and the machine will retry after 4 minutes.

How do I reset an Ice-O-Matic ice machine?

On a CIM cuber, hold the Power and Clean buttons together for 3 seconds: the codes clear and the counters reset (one blue and yellow flash). Fix the cause first, or the code will come back. On a GEM, MFI or HEM machine locked out with a steady Service light, switch the machine off and on again. On a GEMU090, press the on/off button. Other brands: how to reset a commercial ice machine.

What is error 7 on an Ice-O-Matic CIM?

A water level error: when the water pump starts, the level in the sump drops and the high float switch should close, and it didn't. Check the floats and the float switch, and that the water pump runs. Error 3, a sump that didn't fill within 5 minutes, points to the water supply, a blocked filter or the water inlet valve instead.

What does the yellow light mean on an Ice-O-Matic CIM?

The yellow light is the Clean light. Slowly flashing with a solid red Power light, a clean cycle is running; solid yellow with solid red, the clean cycle has finished. Quick yellow flashes together with red flashes are errors 3, 4 and 7. The board also has a cleaning reminder, every 6 months by default (3 months with switch 3 on, for hard water); the manual doesn't say which light shows it. If the machine is due, clean and sanitize it.

Does Ice-O-Matic have error codes for GEM, MFI and HEM machines?

Not numbered ones. The control board has seven indicator lights: WTR-OK and PWR-OK (green, normally on), Service (red, normally off), Freeze, Bin Full, and two white relay lights. A blinking or steady Service light means an auger motor overload, WTR-OK off means no water, and Bin Full on with an empty bin means the ice level sensors are blocked or scaled.

Sources

More guides

Data sources

Last updated