What size ice machine do I need? How to size a commercial ice machine
By IcePartsDB · Updated · 12 min read
In this guide · 9 sections
- Step 1: How much ice does your business use in a day?
- Step 2: Plan for your busiest day, not an average one
- Step 3: Rated output vs what the machine really makes
- Step 4: How big should the bin be?
- Worked examples
- One big machine or two smaller ones?
- Find machines of the right size
- Questions and answers
- Sources
Short answer: Add up your busiest day with the makers' rules of thumb: about 1.5 to 1.7 lb of ice per restaurant customer, 3 lb per bar seat or customer, 3 to 5 lb per hotel room, 8 to 10 lb per hospital bed and 1 lb per cafeteria customer. Add a margin for busy days and growth (Ice-O-Matic suggests at least 20 percent on new installations, Scotsman 10 to 20 percent). Then choose a machine whose output at your real air and water temperatures covers that total. The standard rating assumes 90 °F air and 70 °F water, and a machine in a hotter room makes less. Size the bin to hold what you use in your busiest stretch, minus what the machine makes during it.
Sizing an ice machine takes three numbers: how much ice you use on your busiest day, how much the machine really makes where it will stand, and how much ice the bin must hold to get you through the rush. The makers publish rules of thumb for the first. Their spec sheets give the second, if you read the right column. The third is simple arithmetic. To do the sums for you, and see real models that fit, use the ice machine sizing calculator; it uses the figures below.
Step 1: How much ice does your business use in a day?
These are the usage figures from the sizing charts Hoshizaki, Manitowoc, Ice-O-Matic and Scotsman publish. They are rules of thumb for one 24-hour day. Where the makers differ, the table shows the range and who says what; Scotsman's figures, from its 2026 product guide, are shown where they differ.
| Where the ice goes | Ice per day | What the makers say |
|---|---|---|
| Restaurant | 1.5 lb per customer | Hoshizaki, Manitowoc and Ice-O-Matic charts: 1.5 lb. A 2025 Hoshizaki article uses 2 lb. Scotsman: 1.7 lb per customer or 5.0 lb per seat. |
| Bar or cocktail lounge | 3 lb per seat | Hoshizaki, Manitowoc and Ice-O-Matic charts. Scotsman: 3 lb per customer. |
| Water glass | 4 oz per 10 oz glass | Hoshizaki and Manitowoc |
| Quick service (fast food) drinks | 5 oz per 7–10 oz cup, 8 oz per 12–16 oz, 12 oz per 18–24 oz | Manitowoc and Ice-O-Matic; Hoshizaki's cup sizes are slightly different. Scotsman: 2 oz per 8–10 oz drink, 4 oz per 12–16 oz, or 0.9 lb per customer (7.4 lb per seat). |
| Convenience store drinks | 6 oz per 12 oz drink, 10 oz per 20 oz, 16 oz per 32 oz | Manitowoc and Ice-O-Matic. Scotsman: 4 oz per 12 oz, 7 oz per 20 oz, 10 oz per 32 oz. |
| Drink dispenser with a cold plate | 45–50% more ice per day | Hoshizaki 45%; Manitowoc, Ice-O-Matic and Scotsman 50% |
| Packaged (bagged) ice | Bag weight × bags sold per day | Hoshizaki, Manitowoc and Ice-O-Matic |
| Hotel guest ice | 3–5 lb per room | Hoshizaki chart and Scotsman 3 lb; Manitowoc, Ice-O-Matic and the Hoshizaki article 5 lb. Scotsman: plan on substantially more if guests may fill ice chests. |
| Catering and banquets | 1–1.5 lb per person | Manitowoc and Ice-O-Matic 1 lb; Hoshizaki 1.5 lb |
| Hospital patient ice | 8–10 lb per bed | Hoshizaki, Ice-O-Matic and the Hoshizaki article 10 lb; Scotsman 8 lb |
| Hospital cafeteria | 1 lb per person | Hoshizaki, Manitowoc and Ice-O-Matic |
| Healthcare staff | 3 lb per employee | Scotsman |
| School cafeteria | 1.5 lb per student | Hoshizaki |
| Office employee ice | 1.5 lb per person (cube), 2 lb (flake or cubelet) | Hoshizaki |
| Salad bar | 30–40 lb per cubic foot of display | Hoshizaki and Manitowoc 30 lb; Scotsman 35 lb; Ice-O-Matic 40 lb |
| Supermarket seafood or salad display | 32 lb per cubic foot (cube), 27 lb (flake) | Hoshizaki |
Add up every place that uses ice: the bar and the dining room, the drink station, the kitchen, the display case. If you already have a machine, your own records beat any rule of thumb: count how many bins or buckets you go through on a busy day.
Display figures (salad bars, seafood cases) are the ice it takes to fill the display. If you refill it during the day, count each refill: Scotsman multiplies its salad bar figure by 2 or 3, depending on the refills.
Step 2: Plan for your busiest day, not an average one
- Use the peak day. Hoshizaki tells buyers to think about peak times such as weekends and holidays. Manitowoc's beverage rule is 40% ice per drink times the number of drinks served on the peak day.
- Plan for summer. Ice-O-Matic's sizing sheet asks whether the existing machine meets peak usage during the hottest time of the year. Hot weather raises how much ice you use and, as the next step shows, lowers how much an air-cooled machine makes.
- Leave room to grow. Ice-O-Matic suggests building in at least 20 percent extra capacity on new installations; Scotsman suggests 10 to 20 percent for new locations, or for unusual uses such as icing down drink barrels or bagging ice for resale.
- Replacing a machine that falls short? Scotsman's rule: add the ice you buy to the old machine's output, and size the new one for the total. If you're still deciding whether to fix the old one, see the repair or replace calculator.
Step 3: Rated output vs what the machine really makes
A machine's "lb per 24 hours" depends on the air around it and the water coming in. Spec sheets often list two figures:
- 90 °F air and 70 °F water. This is the standard, certified rating (DOE and AHRI). Scotsman's Ice Production FAQ Information Sheet calls it typical conditions and says it is the condition used for the AHRI harvest rate, and its product guide calls this figure the "AHRI certified" production. The harvest rates in the DOE and ENERGY STAR data, which every machine page here shows, come from the DOE test procedure, which uses AHRI Standard 810.
- 70 °F air and 50 °F water. Scotsman calls these ideal conditions and the figure its "maximum" production. It is always higher, and it is often the one in the model name or the headline.
Two examples from the makers' own documents:
- Hoshizaki KM-515MAJ (air-cooled crescent cuber): up to 517 lb a day at 70 °F air and 50 °F water, and 450 lb at 90 °F air and 70 °F water, per its spec sheet. That is 13% less at the standard rating.
- Manitowoc IP0500A (air-cooled, Indigo NXT). Manitowoc's model numbers give the nominal production at 70 °F air and 50 °F water, so "0500" means about 500 lb a day. The production chart in the technician's handbook shows what happens as conditions change:
| Air temperature at the condenser | 50 °F water | 70 °F water | 90 °F water |
|---|---|---|---|
| 70 °F | 520 lb | 455 lb | 415 lb |
| 90 °F | 450 lb | 400 lb | 360 lb |
| 100 °F | 410 lb | 360 lb | 330 lb |
| 110 °F | 390 lb | 340 lb | 305 lb |
So the same machine can make anything from 520 lb to 305 lb a day. In a 100 °F corner of a kitchen with 70 °F water it makes 360 lb, which is 10% below its 400 lb standard rating and about 30% below its nominal size.
What this means when you choose:
- Compare machines at 90 °F air and 70 °F water, or better, at the temperatures your room really reaches in summer. Don't compare one maker's 70/50 figure with another's 90/70 figure.
- Water-cooled and remote machines hold their output better in a hot room, because their condenser isn't using room air. Manitowoc's chart for the water-cooled IP0500W still shows 380 lb at 110 °F room air and 70 °F water, against 340 lb for the air-cooled IP0500A. Water-cooled machines cost far more to run, though: see running costs by cooling type.
- A remote machine's output also depends on the length of the refrigerant lines, per Scotsman's FAQ sheet.
- An air-cooled machine needs its clearances. The installation manual lists the free space it needs around the vents; a machine squeezed into a closed cabinet makes less ice.
- A machine loses output as it scales up. Scotsman lists water quality and the age and condition of the machine as factors too. Keep it clean: see how to clean a commercial ice machine.
Manitowoc's handbook also says a production check within 10% of its chart is considered normal. If your machine is further off than that, it may need service; see ice machine not making ice.
Step 4: How big should the bin be?
Most modular machines are ice-making heads. The DOE defines them as ice makers that "do not contain integral storage bins, but are generally designed to accommodate a variety of bin capacities", and the EPA describes modular machines as designed to sit on top of a separate unit, such as an ice bin, beverage machine or ice dispenser. The machine refills the bin around the clock, so the bin doesn't need to hold a whole day's ice. It needs to hold what you use in your busiest stretch, minus what the machine makes during that stretch.
- Estimate how much ice you use in the busiest stretch (for example, the dinner rush).
- Work out what the machine makes in the same hours: daily output ÷ 24 × hours.
- The bin should hold at least the difference, plus a margin.
- Check that the machine has time to refill the bin before the next rush.
Bin capacities are maximums: Scotsman, for example, rates its bins at 90% of their volume at 34 lb per cubic foot. Use the bin maker's recommended bins for your head. Manitowoc's handbook notes that its machines need the bin or dispenser to have an ice deflector, and asks you to check compatibility before using another maker's bin. Bins sold for the three brands: Hoshizaki and Manitowoc ice bins.
Worked examples
These use the arithmetic above; the sizing calculator does the same sums and lists machines that meet the total.
A restaurant with a bar. 220 customers on a busy Saturday and a 20-seat bar:
- Ice per day: 220 × 1.5 lb = 330 lb, plus 20 × 3 lb = 60 lb. Total 390 lb.
- Add 20% for growth and hot days: about 470 lb.
- The machine goes in a kitchen that reaches 90 °F in summer, so look for about 470 lb at 90 °F air and 70 °F water, not at 70/50.
- Bin: say half the day's ice goes in a 4-hour dinner rush, about 195 lb. A 470 lb machine makes about 78 lb in 4 hours (470 ÷ 24 × 4). The bin should start the rush with at least 117 lb (195 − 78), so a bin that holds well over that is the right size.
A hotel. 120 rooms with guest ice machines on the floors, and banquets for up to 150 people:
- Guest ice: 120 × 5 lb = 600 lb. Banquets: 150 × 1 lb = 150 lb. Total 750 lb, about 900 lb with a 20% margin.
- Guest ice is spread over floors, so it usually comes from several smaller machines or dispensers, one per floor or two. The banquet kitchen gets its own.
A hospital unit. 40 beds and a cafeteria serving 300 people a day:
- Patient ice: 40 × 10 lb = 400 lb (320 lb at Scotsman's 8 lb per bed). Cafeteria: 300 × 1 lb = 300 lb.
- Patient ice is often nugget or flake (Hoshizaki says patients benefit from soft cubelet and flaked ice, and Scotsman markets both for therapeutic use) and cafeteria drinks often cube, so these may be two different machines. See cube vs nugget vs flake ice.
One big machine or two smaller ones?
Two smaller machines cost more than one big one, but if one fails you still have ice. They also let you put the ice where it is used (bar and kitchen, or floor by floor). Many modular heads can be paired: Hoshizaki's spec sheet for the KM-515MAJ, for example, says two units can be mounted side by side. Ask the maker or dealer which combinations and bins are approved for your model.
Find machines of the right size
The Hoshizaki, Manitowoc and Scotsman machine lists show every DOE and ENERGY STAR model with its certified harvest at 90 °F air and 70 °F water, ice type and cooling type. Each machine page also shows its energy and water use, a yearly running cost and live eBay listings for that model. To compare the brands, see Hoshizaki vs Manitowoc vs Scotsman. Buying second-hand? Read buying a used ice machine on eBay first. What each size sells for, new and used: how much does a commercial ice machine cost?
Questions and answers
How much ice does a restaurant need per day?
About 1.5 lb per customer, according to the sizing charts from Hoshizaki, Manitowoc and Ice-O-Matic (a 2025 Hoshizaki article uses 2 lb; Scotsman uses 1.7 lb per customer or 5 lb per seat). Add 3 lb per bar seat if you have a bar, use your busiest day, and add a margin: Ice-O-Matic suggests at least 20 percent on new installations, Scotsman 10 to 20 percent. The ice machine sizing calculator does the sums.
What size ice machine do I need for a bar?
Allow about 3 lb of ice per seat per day, the figure in the Hoshizaki, Manitowoc and Ice-O-Matic charts (Scotsman uses 3 lb per customer). A 40-seat bar needs about 120 lb a day before any margin. Add the ice for the dining room and kitchen if the same machine serves them.
How many pounds of ice does a hotel need per room?
The makers' figures range from 3 lb per room (Hoshizaki's chart and Scotsman) to 5 lb per room (Manitowoc, Ice-O-Matic and a 2025 Hoshizaki article) for guest ice; Scotsman says to plan on substantially more if guests may fill ice chests. Count banquets and restaurants separately, at about 1 to 1.5 lb per person.
Why does my ice machine make less ice than its rating?
Because the rating assumes set conditions. Many headline figures are at 70 °F air and 50 °F water; the standard rating is at 90 °F air and 70 °F water. A hotter room, warmer water, a dirty condenser, missing clearances or scale all lower the output. Manitowoc's chart for one 500-size machine runs from 520 lb a day in cool conditions to 305 lb in very hot ones.
What does 90/70 mean on an ice machine spec sheet?
It is the ice production with 90 °F air around the machine and 70 °F water coming in, the standard rating condition for the AHRI harvest rate. A "70/50" figure is at 70 °F air and 50 °F water and is always higher. Compare machines at the same conditions.
Should the ice bin hold a whole day's ice?
No. The machine refills the bin around the clock. The bin needs to hold what you use in your busiest stretch, minus what the machine makes during it, plus a margin. Bin capacities are maximums (Scotsman rates its bins at 90% of their volume), so leave room. Use a bin the machine's maker recommends for that head.
Sources
- Hoshizaki America, Ice Machine Sizing Guide (usage chart and ice types by model series), copy hosted by a dealer.
- Hoshizaki America, Choosing the Right Ice Machine for Your Business, June 10, 2025 (usage per customer, seat, room and bed; peak demand).
- Manitowoc Ice, Ice Usage Guide (catalog page 43), copy hosted by WebstaurantStore.
- Ice-O-Matic, Sizing your Ice-O-Matic ice maker, revised December 17, 2018 (usage per day, peak in the hottest time of year, 20 percent extra capacity), copy hosted by a dealer.
- Scotsman Ice Systems, Commercial Product Guide, SIS-BR-CPG_0726, July 2026: Equipment Sizing Guidelines (page 7), definitions of maximum and AHRI certified production and of bin capacity (page 39).
- Scotsman Ice Systems, Ice Production FAQ Information Sheet (90 °F/70 °F typical and 70 °F/50 °F ideal conditions, AHRI harvest rate, factors that lower production).
- Manitowoc Ice, Indigo NXT Air/Water/Remote Condenser Ice Machines Technician's Handbook, Part Number 000018553 Rev 00 04/26: model nomenclature (page 22), ice deflector notice (page 23), clearances (page 28), ice production check (pages 110–111), IP0500A and IP0500W production charts (pages 232–233).
- Hoshizaki America, KM-515M_J Slim-Line Modular Crescent Cuber spec sheet, 02/23/18, copy hosted by Wasserstrom (ice production at 70/50 and 90/70).
- U.S. Department of Energy, test procedure for automatic commercial ice makers, 10 CFR 431.134 (AHRI Standard 810), and definitions (ice-making head, harvest rate), 10 CFR 431.132.
- U.S. EPA, Technology Transitions final rule, 88 FR 73098, October 24, 2023, page 73164 (modular ice machines sit on a separate bin, beverage machine or dispenser).
Browse by brand
More guides
- Ice machine not making ice? Causes, checks and the parts that fix them
- Hoshizaki ice machine beeping? What 1, 2, 3, 6 and 7 beeps mean (error codes)
- Manitowoc ice machine error codes (Indigo NXT E01 to E31): meanings and fixes
- Scotsman ice machine error codes: Prodigy code display meanings and fixes
- Ice-O-Matic ice machine error codes: CIM flashing lights, GEM and MFI service lights
- How to reset a commercial ice machine (Hoshizaki, Manitowoc, Scotsman, Ice-O-Matic)
- Ice machine water inlet valve: symptoms, testing and replacement
- Ice machine water pump: symptoms, testing and replacement
- Ice machine float switch and water level probe: symptoms, testing and replacement
- Ice machine control board: signs of failure, what to check first, and replacement
- Ice thickness probe and thermistor: how ice machines decide when to harvest
- Ice machine condenser fan motor: symptoms, testing and replacement
- Ice machine bin control: bin thermostats, curtain switches and ice level sensors
- Flake and nugget ice machine auger and gear motor: wear, noise and replacement
- How to clean and sanitize a commercial ice machine (and how often)
- How to find your ice machine's model number and the right part number
- Ice machine serial number lookup: how old is my Hoshizaki, Manitowoc, Scotsman or Ice-O-Matic?
- How long do commercial ice machines last? Lifespan, what shortens it and when to replace
- Ice machine recalls: is your ice machine affected?
- Cube vs nugget vs flake ice: the ice types and the machines that make them
- Air-, water- or remote-cooled ice machine? Running costs compared
- How much does a commercial ice machine cost? Machines, running costs, repairs and parts
- Ice machine water filters: why they matter, when to change them and how to size one
- Buying a used commercial ice machine on eBay: a checklist
- OEM vs aftermarket ice machine parts: price gap and when each makes sense
- Hoshizaki vs Manitowoc vs Scotsman: which commercial ice machine brand is best?
- Ice machine refrigerants and the EPA rules: R-404A, R-410A, R-134a, R-290 and the 2026–2027 deadlines
Data sources
- IcePartsDB editorial — written from the data above, the sources linked in the text and general trade practice; not a substitute for the machine's manual or a qualified technician
- How we build these pages (methodology)
- Report a correction to this page
Last updated