  1. How often to clean an ice machine
  2. What you need
  3. Cleaner vs sanitizer, and what "nickel-safe" means
  4. Safety: never mix cleaner and sanitizer
  5. Step by step: cleaning and sanitizing
  6. While it is open: the 10-minute check
  7. Do it yourself or hire a service company?
  8. Questions and answers
  9. Sources

Short answer: Clean (descale) and sanitize a commercial ice machine as often as its manual says, and more often with hard water or in a dusty or greasy kitchen; Manitowoc, Scotsman and Ice-O-Matic call for at least every six months. Use the cleaner and sanitizer the maker approves and never mix them: ice machine cleaner is an acid, and acid mixed with a chlorine sanitizer can release chlorine gas. Rinse well between the two, wear gloves and eye protection, and follow the machine's own clean cycle. Clean the air-cooled condenser and change the water filter at the same time, and keep a log for the health inspector.

Ice is food. A dirty ice machine grows slime and mold, makes cloudy, bad-tasting ice, and loses capacity as mineral scale builds up on the evaporator. Regular cleaning is also the cheapest repair you can make: scale is one of the most common causes of an ice machine making too little ice or none (see the not making ice guide).

How often to clean an ice machine

  • What the rules say. The FDA Food Code, which U.S. health departments adopt in their own versions, treats ice makers as enclosed food equipment: clean them at the frequency the manufacturer specifies or, without one, often enough to prevent soil or mold building up (2026 Food Code, section 4-602.11(E)(4)). Your local health department enforces its own version, so check it.
  • What the makers say. Manitowoc says to de-scale and sanitize its Indigo NXT machines at least once every six months. Scotsman says the water system of its Prodigy cubers should be cleaned and sanitized at least twice a year. Ice-O-Matic says to clean its CIM cubers at least every 6 months, and to descale no more than once a month, sanitizing after each descaling. Hoshizaki's service manual for its KML crescent cubers lists cleaning and sanitizing as a yearly task, with more frequent maintenance where water quality, the location or local sanitation rules call for it. The manual for your model is the authority.
  • When to clean more often. Hard water, a dusty or greasy kitchen (flour, frying), a hot room and heavy use all speed up scale and slime. Manitowoc suggests having the water tested and treated if the machine needs de-scaling more often than every six months; see the water filter guide.
  • Signs it's overdue: cloudy or soft ice, slime (often pink or black) in the trough or on the curtain, odd taste or smell, smaller output, or harvests that take longer than usual. Some machines also light a clean or de-scale reminder.

What you need

  • The ice machine cleaner (descaler) and sanitizer the manufacturer approves for your machine. Manitowoc reminds users that using these products in a way that is inconsistent with their labels is a violation of federal law.
  • Rubber gloves and safety goggles or a face shield, a soft-bristle nylon brush, sponge or cloth (Manitowoc: not a wire brush), and a bucket of warm water.
  • A new water filter cartridge, if the machine has a filter: Manitowoc and Ice-O-Matic water filters.
  • The machine's manual, for its cleaning cycle, mixing ratios and which parts come out.

Cleaner vs sanitizer, and what "nickel-safe" means

An ice machine needs two different products, used one after the other and never mixed:

  • Ice machine cleaner (descaler) is an acid. It dissolves the mineral scale that hard water leaves on the evaporator and in the water system, which is what turns ice cloudy and slows the harvest.
  • Ice machine sanitizer kills the bacteria, yeast and mold that grow as slime in damp places: the trough, the curtain, the bin. It is usually a quaternary ammonium or chlorine solution at the strength the maker gives (see sanitizing).

Nickel-safe cleaners are formulated not to attack nickel plating. Many cube machines have nickel-plated copper evaporators, and the wrong acid strips the plating so that the ice sticks and harvests poorly (see nickel-safe cleaner). Ice-O-Matic requires a nickel-safe cleaner and a nickel-safe sanitizer for its CIM cubers. The other makers name the cleaner and sanitizer they approve in each model's manual: use those, at the dilution on their labels.

Safety: never mix cleaner and sanitizer

Ice machine cleaner contains acids (Scotsman's warning label says so, and that acids can cause burns). Many sanitizers are chlorine-based; some Hoshizaki manuals, for example, specify diluted chlorine bleach as the sanitizer. Chlorine bleach mixed with acidic cleaners can release chlorine gas: the CDC's Agency for Toxic Substances and Disease Registry warns not to mix bleach with other cleaners such as toilet cleaners for that reason. So:

  • Never mix the cleaner and the sanitizer, in a bucket or in the machine. Manitowoc says the same on its de-scaler and sanitizer.
  • Run the full rinse between cleaning and sanitizing, as the manual directs (Hoshizaki's procedure repeats its rinse three more times before sanitizing), so no cleaner is left when the sanitizer goes in.
  • Keep the area ventilated, wear gloves and eye protection, and keep the chemicals in their original containers.
  • Don't use household bleach, vinegar or other products unless the manual says so. Makers differ here: Ice-O-Matic requires a nickel-safe cleaner and a nickel-safe sanitizer for its CIM cubers and says never to use chlorine-based solutions such as bleach on them, nor vinegar stronger than food grade or acids such as hydrochloric acid.

Step by step: cleaning and sanitizing

These are the general steps; your manual gives the exact sequence, quantities and times.

  1. Stop at the end of a harvest. Let the machine finish harvesting so the evaporator is free of ice, then switch it off or select its clean or wash mode.
  2. Empty the bin. Remove all the ice (discard it or keep it in a clean container away from the machine).
  3. Run the cleaning cycle. In clean mode, add the measured cleaner to the water trough as the manual says. The machine circulates it over the evaporator and through the water system to dissolve scale. Some Hoshizaki cubers have a cleaning valve that you open so the solution also flows over the inside of the evaporator plates.
  4. Clean the removable parts by hand. Switch off and unplug the machine. Remove the parts the manual lists (water curtain or splash shield, distribution tube, water trough, float switch or water level probe, ice thickness probe) and soak and scrub them in cleaner solution. Don't soak electrical connectors, and never put an ice thickness probe in a dishwasher (Manitowoc warns this damages it permanently). Clean the areas they cover.
  5. Rinse. Rinse the parts and the inside well with clean water, refit them, and let the machine run its rinse cycles as the manual directs.
  6. Sanitize. Repeat the cycle and the hand cleaning with the sanitizer solution. Sanitize the inside of the bin, the bin door and the ice scoop too.
  7. Restart and check. Close the cleaning valve if the machine has one: Hoshizaki cubers won't restart in ICE mode while it is open. Return the machine to ice mode and discard the ice made during cleaning and sanitizing (Manitowoc says all of it must be discarded). Check that the water flows evenly over the evaporator and the ice releases cleanly.
  8. Log it. Write down the date, what was done and by whom.

While it is open: the 10-minute check

Cleaning day is the best time to catch the parts that cause breakdowns:

  • Condenser (air-cooled machines): switch off the power, wear gloves (Manitowoc warns that the fins are sharp) and clean it the way your manual says: Hoshizaki, with a brush or vacuum cleaner; Manitowoc, with compressed air or a water rinse from the inside out, calling a service agent if dirt remains; Scotsman, by washing the air filter, with a refrigeration technician to clean the fins if the machine has run without its filter. A clogged condenser makes the machine run hot, lose capacity and trip its safety switch. Check that the fan turns freely (see the condenser fan motor guide; Hoshizaki, Manitowoc, Scotsman and Ice-O-Matic condenser fan motors).
  • Water filter: replace the cartridge on its schedule, or sooner if the pressure gauge or flow says it's clogged.
  • Float switch or water level probe: clean it and check the float slides freely; see the float switch guide.
  • Ice thickness probe: clean it and check its gap; see the ice thickness probe guide.
  • Water pump and distribution tube: clear scale from the impeller and the tube's holes; see the water pump guide.
  • Water inlet screen: Hoshizaki lists cleaning the inlet screen as a yearly task; see the water inlet valve guide.
  • Drains: pour warm water through the bin drain and check the machine drain runs freely.
  • Curtains, gaskets and the bin door: look for cracks, warping and torn gaskets that let warm air or splashes in; check that the curtain swings freely (see the bin control guide).

Do it yourself or hire a service company?

Most operators clean the machine themselves between visits, following the manual. A service company is worth it for heavily scaled machines, hard-to-reach areas, and a full check of the refrigeration system. Manitowoc notes that an extremely dirty machine must be taken apart for descaling and sanitizing. If the machine shows a code after cleaning, see the Hoshizaki, Manitowoc, Scotsman or Ice-O-Matic error code guide.

Questions and answers

How often should a commercial ice machine be cleaned?

As often as the manufacturer's manual says, and more often with hard water, heavy use or a dusty or greasy kitchen. Manitowoc calls for de-scaling and sanitizing at least every six months, Scotsman for cleaning and sanitizing at least twice a year, and Ice-O-Matic for cleaning its CIM cubers at least every 6 months. The FDA Food Code requires cleaning at the manufacturer's frequency, or often enough to prevent soil and mold.

What is nickel-safe ice machine cleaner?

A scale remover made not to attack the nickel plating on many ice machine evaporators; an ordinary acid can strip the plating so ice sticks and harvests poorly. Ice-O-Matic requires a nickel-safe cleaner and sanitizer for its CIM cubers; for other machines, use the cleaner the model's manual names.

What is the difference between ice machine cleaner and sanitizer?

The cleaner (descaler) is an acid that removes mineral scale; the sanitizer kills the bacteria, yeast and mold that grow as slime. A full cleaning uses both, one after the other with a rinse in between, and never mixed: acid cleaner and chlorine sanitizer together give off chlorine gas.

Can I use CLR to clean my ice machine?

Not unless the manual names it. The makers specify their own approved ice machine cleaners, and Ice-O-Matic's CIM manual warns against acids such as hydrochloric acid and against vinegar stronger than food grade, because the wrong acid can strip the nickel plating on the evaporator.

Is there a homemade ice machine cleaner?

No safe substitute that the makers approve. Use the ice machine cleaner and sanitizer the manual names, at the dilution on their labels; household mixtures can damage the evaporator plating and, with chlorine, release toxic gas.

How do I get rid of mold in an ice machine?

Run the full cleaning and sanitizing procedure in the manual: take out the parts it lists (curtain, trough, distributor, probes) and scrub them in the cleaner solution with a soft brush, sanitize them and every surface the water and ice touch, including the bin, and throw away the ice made during cleaning. Mold that keeps coming back means the machine needs cleaning more often.

What are the white floaties in my ice?

Usually mineral scale from hard water breaking off the evaporator or the water system. Clean (descale) and sanitize the machine, and check the water filter: a fresh cartridge, or a filter with scale control, slows it down.

Can I use vinegar to clean a Manitowoc ice machine?

Use the de-scaler and sanitizer Manitowoc approves for the machine, as its handbook says, at the dilution on their labels; Manitowoc notes that using them in a way that is inconsistent with their labels is a violation of federal law. Vinegar isn't a substitute unless the manual says so.

How do I clean a Manitowoc ice machine?

Follow the de-scaling and sanitizing procedure in the machine's handbook, at least every six months: let it finish a harvest, empty the bin, run the clean cycle with Manitowoc-approved de-scaler, take out and scrub the parts the handbook lists with a soft brush (never put the ice thickness probe in a dishwasher), rinse, then repeat with the sanitizer, never mixed with the de-scaler. Discard all the ice made during cleaning.

How do I clean a Hoshizaki ice machine?

Use the cleaning and sanitizing procedure in the model's service manual: at the end of a harvest, empty the bin, run the cleaning solution through the water system (on cubers with a cleaning valve, open it so the solution also flows over the inside of the evaporator plates), clean the removable parts, rinse three more times, then sanitize. Close the cleaning valve afterwards: the machine won't restart in ICE mode while it is open.

Why must ice machine cleaner and sanitizer never be mixed?

Ice machine cleaner is an acid, and many sanitizers contain chlorine. Mixing chlorine bleach with acidic cleaners can release chlorine gas, which is dangerous to breathe. Use them one after the other, with the machine's full rinse in between, wear gloves and eye protection, and keep the area ventilated.

Can I use vinegar or bleach to clean an ice machine?

Only if the manual says so. Use the cleaner (descaler) and sanitizer the manufacturer approves, at the dilution it gives. Some Hoshizaki manuals do specify diluted chlorine bleach as the sanitizer; never use bleach together with, or straight after, an acid cleaner without the rinse in between.

What is the pink or black slime in my ice machine?

Usually bacteria or mold growing in damp areas such as the trough, the curtain and the bin. It means the machine is overdue for cleaning and sanitizing; remove and scrub the parts it grows on, and sanitize the bin.

What happens if you don't clean your ice machine?

Scale and slime build up: the ice turns cloudy or soft, slime (often pink or black) grows in the trough and on the curtain, output drops and harvests take longer, and the machine can stop making ice altogether. The FDA Food Code also requires cleaning at the manufacturer's frequency, and DOE notes that regular maintenance plays a critical role in how long a machine lasts.

Should I throw away the first batch of ice after cleaning?

Yes. Discard the ice made during cleaning and sanitizing; Manitowoc says all of it must be discarded, and the EPA's WaterSense guidance suggests making and discarding several batches to remove any cleaning solution.

How do I run the clean cycle on an Ice-O-Matic CIM?

Remove the ice from the bin, hold the Power button for 3 seconds for a harvest and wait for the Power light to turn solid red (off). Then press Clean: the machine shows solid red and flashing yellow, empties and refills the sump, and when the pump starts you pour in the nickel-safe descaler, measured for the machine's sump size (the manual has a chart). It washes for 15 minutes, then purges and rinses several times and stops with a solid red and yellow light; press Clean to return to off. Wipe down the evaporator and splash surfaces, repeat the cycle with sanitizer, then press Power to make ice. Once started, the clean cycle can't be stopped.

Why won't my Hoshizaki restart after cleaning?

Check the cleaning valve. On Hoshizaki cubers that have one, it is opened for cleaning and must be fully closed afterwards, or the machine won't restart when the control switch is put back to ICE.

Does cleaning an ice machine void the warranty?

Cleaning keeps the machine in the condition the warranty expects; using unapproved chemicals or skipping the maker's procedure can cause damage that isn't covered (Manitowoc notes that maintenance is not covered by its warranty). Keep a log of each cleaning.