Manitowoc ice machine error codes (Indigo NXT E01 to E31): meanings and fixes

By IcePartsDB · Updated · 8 min read

In this guide · 8 sections
  1. How to read alerts on an Indigo NXT
  2. Every Indigo NXT alert code
  3. E01 Long Freeze: what to check
  4. E02 Long Harvest: what to check
  5. Thaw cycle and safe mode
  6. Restarting after a shutdown
  7. Questions and answers
  8. Sources

Short answer: Indigo NXT machines show an alert icon on the touchscreen; tap it to open the alert log, where each alert has a short text and an E code. The two that shut the machine down until someone restarts it are E01 Long Freeze (the freeze cycle reached 35 minutes three cycles in a row) and E02 Long Harvest (the harvest reached 7 minutes three cycles in a row). Restart with the green power button or by switching the power off and on, at most three times in 24 hours, and find the cause first. E05 (high pressure cut-out) stops the machine for 10 minutes before it retries; most other codes point to a sensor, the water system or the refrigeration system.

This guide covers the Manitowoc Indigo NXT ice machines (the IYT, IDT, IYF, IDF, IRT and related models, and the R290 models IYP, IDP and IRP), from Manitowoc's Indigo NXT technician's handbook. For any other Manitowoc series, use the technician's handbook for that series.

Safety first. The machine's power switch does not disconnect all incoming power: switch off and lock out the main power supply disconnect before any work inside. R290 (propane) models contain a flammable refrigerant; only refrigeration technicians trained for flammable refrigerants may work on their refrigeration system, and Manitowoc requires their replacement parts to come from its authorized parts network. Other refrigeration work needs a technician certified under EPA Section 608.

How to read alerts on an Indigo NXT

  • An alert icon with a number appears on the touchscreen when there are alerts. Tap it to open the alert log, where you can read and clear them. The log is also in the service menu ("Alert Log: lists/clears alerts").
  • The data history in the same menu shows minimum and maximum freeze and harvest times, which helps when a fault comes and goes.
  • If the machine shuts down on Long Freeze or Long Harvest, a green power button appears on the display.
  • Manitowoc advises resetting the control board to factory defaults before troubleshooting, after writing down (or copying to USB) any customer settings, so a changed setting isn't mistaken for a fault.

Every Indigo NXT alert code

Display text Code Meaning What triggers it
Long Freeze E01 Long freeze cycle The freeze cycle reaches 35 minutes three cycles in a row (each 35-minute freeze is ended by a forced harvest); the machine shuts down
Long Harvest E02 Long harvest cycle The harvest reaches 7 minutes three cycles in a row (each one is followed by a thaw cycle); the machine shuts down
Power Loss E03 Input power loss Power to the machine was interrupted; logged when it comes back
Hi cnd Temp / Wtr Cnd Fault E04 High condenser temperature The liquid line temperature is too high for an air-cooled or water-cooled self-contained machine
HPC Fault E05 High pressure control opened The high pressure cut-out switch opened: the machine stops, waits 10 minutes and tries again, repeating while the switch stays open
Starving TXV E07 Starving expansion valve or low charge (single evaporator) Evaporator inlet and outlet temperatures differ by more than 12 °F in the last minute of the freeze cycle
TXV Fault E08 Expansion valve fault (single or dual circuit evaporators) The same temperature-difference test as E07
Flood Evap1 E09 Flooding evaporator, single evaporator, single circuit The compressor discharge temperature in the first 6 minutes of the freeze cycle doesn't rise far enough above the pre-chill reading
Flood Evap2 E10 Flooding evaporator, dual expansion valve, dual circuit The same test as E09
Refrig Fault E11 Refrigeration fault From start-up to 2 minutes into the freeze cycle, the discharge temperature didn't rise by 10 °F and the evaporator temperature didn't fall by 10 °F
Curtain Fault E12 Curtain switch open more than 24 hours The machine is set to make ice but has read "bin full" for over 24 hours: curtain open or off
Low liq temp E15 Fan cycle control fault The liquid line stays below 60 °F for more than a minute during freeze
Rmt Cnd Fault E16 Remote condensing unit fault Remote condensing (CVD) models only: the liquid line goes below 40 °F or above 140 °F for over a minute during freeze
ITP Fault E19 Ice thickness probe fault The probe's signal is out of range (unplugged or failed)
WTR Fault E20 Water system fault The high water probe senses water but the low one doesn't; or the evaporator outlet is below −10 °F 6.5–7.5 minutes into freeze; or the low water probe still senses water at the end of harvest
T1 to T4 Fault E21 to E24 Temperature sensor issue One of the four temperature sensors (thermistors) reads outside its valid range during pre-chill
Bin Probe Fault E25 Bin level probe low sensor fault The bin level sensor reads out of range for 10 minutes
iAUCS E28 Automatic cleaning system The iAuCS cleaning option was chosen but its board isn't detected; clears when the hardware is detected
Safe Mode E31 Safe mode The machine is running on stored cycle data because the water level or ice thickness probe failed

The parts behind the most common alerts: water level probes (Manitowoc float switches), ice thickness probes and thermistors (Manitowoc thermistors & sensors), Manitowoc water inlet valves, Manitowoc water pumps, Manitowoc condenser fan motors, Manitowoc hot gas valves and Manitowoc control boards.

E01 Long Freeze: what to check

Manitowoc says these shutdowns are most often caused by a minor problem or something outside the machine, often intermittent: a cold room at night, a drop in water pressure, water turned off one night a week. Rule out external and electrical causes before the refrigeration system. Its checklist:

  • Installation: work through the installation and visual inspection checklist in the handbook.
  • Water: pressure between 20 and 80 psi, inlet water no warmer than 90 °F, a clean water distribution tube, a working water fill valve, dump valve and water pump, no water lost from the sump, and a clean, working water level probe. See the water inlet valve and water pump guides.
  • Electrical: low incoming voltage, an ice thickness probe out of adjustment (see the ice thickness probe guide), a harvest that isn't started electrically, a contactor that doesn't energize, a compressor that doesn't run electrically, a failed fan cycling control or fan motor.
  • Air and heat: dirty condenser fins or restricted airflow, hot inlet air, or discharge air recirculating to the condenser.
  • Refrigeration (technician): non-Manitowoc components, wrong refrigerant charge, non-condensables in the system, restricted high-side lines, a failed head pressure control, harvest valve or compressor, an expansion valve starving or flooding.

E02 Long Harvest: what to check

  • Water and scale: a dirty evaporator, a dump valve that doesn't work, the drain vent tube missing, water freezing behind the evaporator, loose plastic extrusions or gaskets on the evaporator, a clogged distribution tube.
  • Electrical: an ice thickness probe out of adjustment, or a bin (curtain) switch closed or failed. A harvest can also start too early when the high water probe circuit is made while the low one is open.
  • Refrigeration (technician): non-Manitowoc components, wrong refrigerant charge, a failed head pressure control or harvest valve, an expansion valve flooding, a failed fan cycling control, or on water-cooled machines a water regulating valve adjusted wrongly or not closing during harvest.

Thaw cycle and safe mode

Two sequences keep an Indigo NXT making ice while an alert is active:

  • Thaw cycle: if the curtain doesn't open within the 7-minute harvest, the machine stops the refrigeration and circulates, dumps and refills water 18 times to melt the ice off (1 to 1¾ hours, depending on the model), then starts a new freeze. To end it early, turn the machine off and on with the keypad; cutting the power instead restarts it in a harvest cycle.
  • Safe mode (E31): if the ice thickness probe (E19) or the water level probe (E20) fails, the board runs the machine on its model data and recent cycle history for up to 72 hours, then goes to standby and turns off. It leaves safe mode by itself if the sensor starts working again.

Restarting after a shutdown

After a Long Freeze or Long Harvest shutdown, press the green power button on the display, or switch the power off and on. The board allows this only three times in 24 hours. Find the cause first: the same fault will stop the machine again.

Questions and answers

What does E01 mean on a Manitowoc ice machine?

E01 is Long Freeze: the freeze cycle reached 35 minutes in three cycles in a row, and the machine shut down. Manitowoc says these shutdowns are most often caused by something outside the machine, such as low water pressure, warm water or a cold room at night; its checklist also includes a dirty water level probe, a clogged distribution tube and a dirty condenser. Refrigeration faults come last.

What does E02 mean on a Manitowoc ice machine?

E02 is Long Harvest: the harvest reached 7 minutes in three cycles in a row, and the machine shut down (each long harvest is followed by a thaw cycle). Manitowoc's checklist includes a dirty evaporator, a stuck curtain or bin switch, the ice thickness probe adjustment, the dump valve and the harvest valve.

How do I reset a Manitowoc Indigo NXT ice machine?

Press the green power button that appears on the display after a Long Freeze or Long Harvest shutdown, or switch the power off and on. It can be restarted this way three times in 24 hours. Clear old alerts in the alert log. Other brands: how to reset a commercial ice machine.

What is Curtain Fault (E12) on a Manitowoc?

The machine has been set to make ice but has read "bin full" for more than 24 hours: the water curtain is open, off, or its switch isn't working. The bin switch is a magnetic reed switch, so refit the curtain and check that its magnet is in place.

What is Safe Mode on a Manitowoc ice machine?

When the ice thickness probe or the water level probe fails, the machine keeps making ice on stored cycle data for up to 72 hours, then turns off. Replace the failed probe within that time.

Sources

  • Manitowoc Ice, Indigo NXT Air/Water/Remote Condenser Ice Machines Technician's Handbook, Part Number 000018553 Rev 00 04/26: safety notices (pages 8–9), restart rules (page 62), alert log and alert log detail (pages 85–91), E01 and E02 checklists (pages 92–95), reset to factory defaults (page 97), bin switch (page 150), high pressure cut-out (page 174).