Manitowoc UDF0240A-161 Self-Contained Ice Machine
The Manitowoc UDF0240A-161 is an air-cooled self-contained ice machine that makes cube ice, rated at 160 lbs of ice per day.
It uses 7.9 kWh per 100 lbs of ice.
Manitowoc's own documents for this model family (installation & use and technician's handbook) are linked below, on Manitowoc's website.
Specifications
- Model number
- UDF0240A-161
- Brand
- Manitowoc
- Equipment type
- self-contained ice machine
- Harvest process
- batch (cuber)
- Ice type
- cube ice
- Cooling
- air-cooled
- Harvest rate (lbs/day)
- 160 (73 kg)
- Energy use (kWh/100 lbs ice)
- 7.9
- ENERGY STAR certified
- No
- DOE basic model
- UDF0240A-161
- eBay listings (ship to US)
- 0
- Short link
- /p/udf0240a-161
What does the UDF0240A-161 cost to run?
- Ice made
- 67 lbs/day
- Electricity
- 1,938 kWh/year ≈ $260/year
- Total
- ≈ $260/year
Formula: lbs/day × 365 ÷ 100 × kWh per 100 lbs × $0.1341/kWh (EIA 2025 U.S. commercial average), plus gallons × $15 per 1,000 gal (assumption: combined water and sewer, as DOE prices it (88 FR 30508 §IV.F.5); local rates vary, so use your bill).
Use your own rates
Electricity $260/year = $260/year
Compare the UDF0240A-161 with other machines and with ENERGY STAR models of its size, a year and over its life.
Manitowoc UDF0240A-161 on eBay
No eBay listings for this exact model right now (eBay checked ).
Parts for the UDF0240A-161
No eBay seller has named the UDF0240A-161 in a part listing yet. The surest way to the right part is the number on the old part: look for a label or a stamped number on it, then search that number in the box at the top.
Manuals from the maker
NEO undercounter cubers (U140, U190, U240, U310): Manitowoc's own documents for this model family, on Manitowoc's website.
- UnderCounter (NEO) Ice Machines: Installation, Operation and Maintenance Manual (PDF, 873 KB, opens manitowocice.com in a new tab)Installation & use · No. 040005890 Rev 07 · revised 2022-08 · PDF, 873 KB, on manitowocice.com
- Undercounter (NEO) Ice Machines: Technician's Handbook (all NEO and NEO UP models) (PDF, 4.3 MB, opens manitowocice.com in a new tab)Technician's handbook · No. 000018622 Rev 00 · revised 2025-04 · PDF, 4.3 MB, on manitowocice.com
These are Manitowoc's own documents, linked where Manitowoc publishes them. IcePartsDB doesn't host or copy them and can't vouch for their contents. Check that your model number is listed on the cover: the document for your exact model and serial number is the authority. Links last opened 2026-11-21.
Age and repair
- Repair or replace the UDF0240A-161?Break-even of a repair against a new or used machine, with this model filled in
- How old is your Manitowoc?Serial-number age lookup for Manitowoc
- Reading Manitowoc serial numbersWhere the serial number is and what it says about the build date
Similar machines
| Model | Harvest (lbs/day) | Energy (kWh/100 lbs) | Cooling | Side by side |
|---|---|---|---|---|
| Manitowoc UYF0240A-161 | 160 | 7.8 | air-cooled | |
| Manitowoc UYP0190A-161BX + 2 | 169 | 6.36 | air-cooled | |
| Manitowoc UDF0240A-261 | 148 | 7.95 | air-cooled | |
| Manitowoc UYF0240A-261 | 148 | 7.95 | air-cooled | |
| Manitowoc UDP0190A-161B + 3 | 175 | 5.83 | air-cooled | |
| Manitowoc UDP0240A-261ZG + 3 | 175 | 6 | air-cooled | |
| Manitowoc UYP0190A-161B + 3 | 180 | 5.83 | air-cooled | |
| Hoshizaki KM-231BAK | 163 | 6.2 | air-cooled | Compare |
Side by side with machines of the same ice type and cooling: UDF0240A-161 vs Ice-O-Matic CIMU220FA90
Questions and answers
How much ice does the Manitowoc UDF0240A-161 make?
It is rated at 160 lbs of ice per 24 hours in DOE's certification database, measured with DOE's test procedure (90 °F air, 70 °F water for air-cooled units). Real output is lower in hot rooms or with warm inlet water.
What does it cost to run the Manitowoc UDF0240A-161?
Making ice 42% of the day, DOE's duty cycle (67 lbs/day), about 1,938 kWh a year: $260 at $0.1341/kWh.
Is the Manitowoc UDF0240A-161 ENERGY STAR certified?
It is not in the current ENERGY STAR list of certified commercial ice machines.
Guides
- Manitowoc ice machine error codes (Indigo NXT E01 to E31): meanings and fixes
Every Manitowoc Indigo NXT alert code, E01 Long Freeze to E31 Safe Mode: what triggers it, what Manitowoc says to check, and how to restart.
- Ice machine not making ice? Causes, checks and the parts that fix them
Why a commercial ice machine makes no ice or too little, in the order a technician checks it, with the parts involved and live eBay prices.
- How to reset a commercial ice machine (Hoshizaki, Manitowoc, Scotsman, Ice-O-Matic)
How to reset or restart a Hoshizaki, Manitowoc, Scotsman or Ice-O-Matic ice machine after an alarm, from each maker's manual, and when not to.
- How to find your ice machine's model number and the right part number
Where the data plate is on Hoshizaki, Manitowoc and Scotsman ice machines, what model numbers mean, and how to find the right replacement part number.
Wrong part or model information? Tell us
Cite this page: /p/udf0240a-161 (canonical: /manitowoc/machines/udf0240a-161)
Sources
- DOE Compliance Certification Database: Automatic Commercial Ice Makers — 7 fields, retrieved 2026-11-21
- EIA, Electricity explained: average U.S. commercial price, 2025 (13.41¢/kWh) — running-cost estimate
- DOE, Energy Conservation Standards for Automatic Commercial Ice Makers, proposed rule (88 FR 30508, May 11, 2023), §IV.E.4 "Duty Cycle" — running-cost estimate: machines make ice 42% of the day (14% for low-capacity machines, rated 50 lb/day or less: §III.B)
- eBay listings (Browse API search results) — 0 active listings matched to UDF0240A-161
- How we build these pages (methodology)
- Report a correction to this page
Last updated