Ice-O-Matic CIM1446FR49 Remote-Condensing Ice Machine
The Ice-O-Matic CIM1446FR49 is a remote-condensing ice-making head that makes cube ice, rated at 1,350 lbs of ice per day.
It uses 4.16 kWh per 100 lbs of ice.
Ice-O-Matic's own documents for this model family (service manual and installation & use) are linked below, on Ice-O-Matic's website.
Specifications
- Model number
- CIM1446FR49
- Brand
- Ice-O-Matic
- Equipment type
- remote-condensing ice-making head
- Harvest process
- batch (cuber)
- Ice type
- cube ice
- Cooling
- remote air-cooled condenser
- Harvest rate (lbs/day)
- 1,350 (612 kg)
- Energy use (kWh/100 lbs ice)
- 4.16
- ENERGY STAR certified
- No
- DOE basic model
- CIM1446FR49
- eBay listings (ship to US)
- 0
- Short link
- /p/cim1446fr49
What does the CIM1446FR49 cost to run?
- Ice made
- 567 lbs/day
- Electricity
- 8,609 kWh/year ≈ $1,155/year
- Total
- ≈ $1,155/year
Formula: lbs/day × 365 ÷ 100 × kWh per 100 lbs × $0.1341/kWh (EIA 2025 U.S. commercial average), plus gallons × $15 per 1,000 gal (assumption: combined water and sewer, as DOE prices it (88 FR 30508 §IV.F.5); local rates vary, so use your bill).
Use your own rates
Electricity $1,155/year = $1,155/year
Compare the CIM1446FR49 with other machines and with ENERGY STAR models of its size, a year and over its life.
Ice-O-Matic CIM1446FR49 on eBay
No eBay listings for this exact model right now (eBay checked ).
Parts for the CIM1446FR49
No eBay seller has named the CIM1446FR49 in a part listing yet. The surest way to the right part is the number on the old part: look for a label or a stamped number on it, then search that number in the box at the top.
Manuals from the maker
CIM Elevation Series cubers (R-290 and R-449A models): Ice-O-Matic's own documents for this model family, on Ice-O-Matic's website.
- CIM Service Manual: Technical Service Manual for Modular CIMs (Elevation Series cubers) (PDF, 8.3 MB, opens iceomatic.com in a new tab)Service manual · revised 2026-05 · PDF, 8.3 MB, on iceomatic.com
- Installation Manual, CIM03 - CIM20 60Hz Products (R-290 and R-449A models) (PDF, 5.0 MB, opens iceomatic.com in a new tab)Installation & use · No. 9081549-01 Rev E · revised 2026-05 · PDF, 5.0 MB, on iceomatic.com
- Ice-O-Matic Parts Manual Lookup: service parts manuals (diagrams, part numbers and quantities) by model (search page, opens iceomatic.com in a new tab)Search page on iceomatic.comSearch there for CIM1446FR49.
These are Ice-O-Matic's own documents, linked where Ice-O-Matic publishes them. IcePartsDB doesn't host or copy them and can't vouch for their contents. Check that your model number is listed on the cover: the document for your exact model and serial number is the authority. Links last opened 2026-11-22.
Age and repair
- Repair or replace the CIM1446FR49?Break-even of a repair against a new or used machine, with this model filled in
- How old is your Ice-O-Matic?Serial-number age lookup for Ice-O-Matic
- Reading Ice-O-Matic serial numbersWhere the serial number is and what it says about the build date
Similar machines
| Model | Harvest (lbs/day) | Energy (kWh/100 lbs) | Cooling | Side by side |
|---|---|---|---|---|
| Ice-O-Matic CIM1446HR49 | 1350 | 4.16 | remote air-cooled condenser | |
| Ice-O-Matic CIM2046HR49 | 1502 | 4.44 | remote air-cooled condenser | |
| Ice-O-Matic CIM2046FR49 | 1502 | 4.44 | remote air-cooled condenser | |
| Hoshizaki KM-1301SRJZ3 | 1330 | 3.83 | remote air-cooled condenser | Compare |
| Hoshizaki KM-1301SRJZ3 + URC-14FZ | 1330 | 3.83 | remote air-cooled condenser | Compare |
| Hoshizaki KMS-1402MLJ + SRK-15J3 | 1325 | 4.55 | remote air-cooled condenser | Compare |
| Manitowoc IDF1800C-161 + CVDF1800-263A | 1375 | 4.63 | remote air-cooled condenser | |
| Manitowoc IDF1800C-161 + CVDF1800-261A | 1375 | 4.63 | remote air-cooled condenser | Compare |
Side by side with machines of the same ice type and cooling: CIM1446FR49 vs Manitowoc IDF1800C-161 + CVDF1800-261
Questions and answers
How much ice does the Ice-O-Matic CIM1446FR49 make?
It is rated at 1,350 lbs of ice per 24 hours in DOE's certification database, measured with DOE's test procedure (90 °F air, 70 °F water for air-cooled units). Real output is lower in hot rooms or with warm inlet water.
What does it cost to run the Ice-O-Matic CIM1446FR49?
Making ice 42% of the day, DOE's duty cycle (567 lbs/day), about 8,609 kWh a year: $1,155 at $0.1341/kWh.
Is the Ice-O-Matic CIM1446FR49 ENERGY STAR certified?
It is not in the current ENERGY STAR list of certified commercial ice machines.
Guides
- Air-, water- or remote-cooled ice machine? Running costs compared
What air-, water- and remote-cooled ice machines cost to run a year, from DOE and ENERGY STAR data, which ENERGY STAR covers, and when each makes sense.
- Ice-O-Matic ice machine error codes: CIM flashing lights, GEM and MFI service lights
Ice-O-Matic CIM cuber error codes 1 to 7 (flashing red and yellow lights), GEM, MFI and HEM service lights, CIMU and GEMU090 signals: causes and resets.
- Ice machine not making ice? Causes, checks and the parts that fix them
Why a commercial ice machine makes no ice or too little, in the order a technician checks it, with the parts involved and live eBay prices.
- How to reset a commercial ice machine (Hoshizaki, Manitowoc, Scotsman, Ice-O-Matic)
How to reset or restart a Hoshizaki, Manitowoc, Scotsman or Ice-O-Matic ice machine after an alarm, from each maker's manual, and when not to.
Wrong part or model information? Tell us
Cite this page: /p/cim1446fr49 (canonical: /ice-o-matic/machines/cim1446fr49)
Sources
- DOE Compliance Certification Database: Automatic Commercial Ice Makers — 7 fields, retrieved 2026-11-21
- EIA, Electricity explained: average U.S. commercial price, 2025 (13.41¢/kWh) — running-cost estimate
- DOE, Energy Conservation Standards for Automatic Commercial Ice Makers, proposed rule (88 FR 30508, May 11, 2023), §IV.E.4 "Duty Cycle" — running-cost estimate: machines make ice 42% of the day (14% for low-capacity machines, rated 50 lb/day or less: §III.B)
- eBay listings (Browse API search results) — 0 active listings matched to CIM1446FR49
- How we build these pages (methodology)
- Report a correction to this page
Last updated